Evaluation of intrastromal corneal ring segments for treatment of keratoconus with a mechanical implantation technique

被引:9
作者
Tunc, Zeki [1 ]
Helvacioglu, Firat [1 ]
Sencan, Sadik [1 ]
机构
[1] Maltepe Univ, Sch Med, Dept Ophthalmol, Istanbul, Turkey
关键词
Intrastromal corneal ring segments; keraring; keratoconus; FEMTOSECOND LASER; TREATING KERATOCONUS; INTACS INSERTS; FOLLOW-UP; MANAGEMENT; ECTASIA; EYE;
D O I
10.4103/0301-4738.109519
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the clinical outcomes of intrastromal corneal ring segment (ICRS) implantation in patients with keratoconus using a mechanical implantation technique. Materials and Methods: Thirty eyes of 17 patients with keratoconus were enrolled. ICRSs (Keraring) were implanted after dissection of the tunnel using Tunc's specially designed dissector under suction. A complete ophthalmic examination was performed, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent, keratometric readings, inferosuperior asymmetry index (ISAI), and ultrasound pachymetry. All 3-, 6-, and 12-month follow-ups were completed, and statistical analysis was performed. Results: The mean preoperative UDVA for all eyes was 1.36 +/- 0.64 logMAR. At 12 months, the mean UDVA was 0.51 +/- 0.28 logMAR (P = 0.001), and the mean preoperative CDVA was 0.57 +/- 0.29 logMAR, which improved to 0.23 +/- 0.18 (P = 0.001) at 1 year. There was a significant reduction in spherical equivalent refractive error from -6.42 +/- 4.69 diopters (D) preoperatively to -1.26 +/- 1.45 D (P = 0.001) at 1 year. In the same period, the mean K-readings improved from 49.38 +/- 3.72 D to 44.43 +/- 3.13 D (P = 0.001), and the mean ISAI improved from 7.92 +/- 3.12 to 4.21 +/- 1.96 (P = 0.003). No significant changes in mean central corneal thickness were observed postoperatively. There were no major complications during and or after surgery. Conclusion: ICRS implantation using a unique mechanical dissection technique is a safe and effective treatment for keratoconus. All parameters improved by the 1-year follow-up.
引用
收藏
页码:218 / 225
页数:8
相关论文
共 50 条
  • [31] Acute corneal hydrops after intrastromal corneal ring segment implantation for keratoconus
    Gueell, Jose L.
    Verdaguer, Paula
    Elies, Daniel
    Gris, Oscar
    Manero, Felicidad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12) : 2192 - 2195
  • [32] Evaluation of anterior and posterior surfaces of the cornea using a dual Scheimpflug analyzer in keratoconus patients implanted with intrastromal corneal ring segments
    Torquetti, Leonardo
    Arce, Carlos
    Merayo-Lloves, Jesus
    Ferrara, Guilherme
    Ferrara, Paulo
    Signorelli, Brenno
    Signorelli, Armando
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (09) : 1283 - 1288
  • [33] Asymmetric intrastromal corneal ring for the treatment of keratoconus
    Vilar de Siqueira, Marcelo Alves
    de Polo, Jhonny
    Gomes, Manuela Benites
    Moreira, Hamilton
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2010, 73 (05) : 454 - 458
  • [34] Intrastromal corneal ring segment SK implantation for moderate to severe keratoconus
    Sansanayudh, Wiwan
    Bahar, Irit
    Kumar, Nikhil L.
    Shehadeh-Mashour, Raneen
    Ritenour, Rusty
    Singal, Neera
    Rootman, David S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (01) : 110 - 113
  • [35] INTACS Followed by KeraRing Intrastromal Corneal Ring Segment Implantation for Keratoconus
    Coskunseven, Efekan
    Kymionis, George D.
    Grentzelos, Michael A.
    Karavitaki, Alexandra E.
    Portaliou, Dimitra M.
    Jankov, Mirko R., II
    Arslan, Ebru
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 371 - 374
  • [36] Complications of intrastromal corneal ring segment implantation using a femtosecond laser for channel creation: a survey of 850 eyes with keratoconus
    Coskunseven, Efekan
    Kymionis, George D.
    Tsiklis, Nikolaos S.
    Atun, Serife
    Arslan, Ebru
    Siganos, Charalambos S.
    Jankov, Mirco
    Pallikaris, Ioannis G.
    ACTA OPHTHALMOLOGICA, 2011, 89 (01) : 54 - 57
  • [37] Evaluation of a Tangential Map-Based Nomogram for Intrastromal Corneal Ring Segments' Implantation in Keratoconus: One Year Results
    Zaky, Adel Galal
    KhalafAllah, Mahmoud Tawfik
    Sarhan, Abdelrahman Elsebaey
    Elsawy, Moataz Faiz
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [38] Measuring Intraocular Pressure in Patients With Keratoconus With and Without Intrastromal Corneal Ring Segments
    Mendez-Hernandez, Carmen
    Arribas-Pardo, Paula
    Cuina-Sardina, Ricardo
    Fernandez-Perez, Cristina
    Mendez-Fernandez, Rosalia
    Saenz-Frances, Federico
    Benitez-del-Castillo, Jose M.
    Garcia-Feijoo, Julian
    JOURNAL OF GLAUCOMA, 2017, 26 (01) : 71 - 76
  • [39] Intrastromal corneal ring segments for advanced keratoconus and cases with high keratometric asymmetry
    Khan, Mohammad I.
    Injarie, Anas
    Muhtaseb, Mohammed
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (01) : 129 - 136
  • [40] Femtosecond-assisted intrastromal corneal ring implantation for keratoconus treatment: a comparison with crosslinking combination
    Von Harbach Ferenczy, Peter Alexander
    Dalcegio, Maiara
    Koehler, Marcela
    Pereira, Thiago Silveira
    Moreira, Hamilton
    Moreira, Luciane Bugmann
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2015, 78 (02) : 76 - 81