Evaluation of intrastromal corneal ring segments for treatment of keratoconus with a mechanical implantation technique

被引:9
|
作者
Tunc, Zeki [1 ]
Helvacioglu, Firat [1 ]
Sencan, Sadik [1 ]
机构
[1] Maltepe Univ, Sch Med, Dept Ophthalmol, Istanbul, Turkey
关键词
Intrastromal corneal ring segments; keraring; keratoconus; FEMTOSECOND LASER; TREATING KERATOCONUS; INTACS INSERTS; FOLLOW-UP; MANAGEMENT; ECTASIA; EYE;
D O I
10.4103/0301-4738.109519
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the clinical outcomes of intrastromal corneal ring segment (ICRS) implantation in patients with keratoconus using a mechanical implantation technique. Materials and Methods: Thirty eyes of 17 patients with keratoconus were enrolled. ICRSs (Keraring) were implanted after dissection of the tunnel using Tunc's specially designed dissector under suction. A complete ophthalmic examination was performed, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent, keratometric readings, inferosuperior asymmetry index (ISAI), and ultrasound pachymetry. All 3-, 6-, and 12-month follow-ups were completed, and statistical analysis was performed. Results: The mean preoperative UDVA for all eyes was 1.36 +/- 0.64 logMAR. At 12 months, the mean UDVA was 0.51 +/- 0.28 logMAR (P = 0.001), and the mean preoperative CDVA was 0.57 +/- 0.29 logMAR, which improved to 0.23 +/- 0.18 (P = 0.001) at 1 year. There was a significant reduction in spherical equivalent refractive error from -6.42 +/- 4.69 diopters (D) preoperatively to -1.26 +/- 1.45 D (P = 0.001) at 1 year. In the same period, the mean K-readings improved from 49.38 +/- 3.72 D to 44.43 +/- 3.13 D (P = 0.001), and the mean ISAI improved from 7.92 +/- 3.12 to 4.21 +/- 1.96 (P = 0.003). No significant changes in mean central corneal thickness were observed postoperatively. There were no major complications during and or after surgery. Conclusion: ICRS implantation using a unique mechanical dissection technique is a safe and effective treatment for keratoconus. All parameters improved by the 1-year follow-up.
引用
收藏
页码:218 / 225
页数:8
相关论文
共 50 条
  • [1] Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique
    Tunc, Zeki
    Helvacioglu, Firat
    Sencan, Sadik
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2011, 59 (06) : 436 - 442
  • [2] Intrastromal Corneal Ring Segment Implantation for the Treatment of Keratoconus
    Kubaloglu, Anil
    Sari, Esin Sogutlu
    Cinar, Yasin
    Koytak, Arif
    Kurnaz, Ekrem
    Ozerturk, Yusuf
    CORNEA, 2011, 30 (01) : 11 - 17
  • [3] KeraRing Intrastromal Corneal Ring Segments for Correction of Keratoconus
    Gharaibeh, Almutez M.
    Muhsen, Sana' M.
    AbuKhader, Ilham B.
    Ababneh, Osama H.
    Abu-Ameerh, Mohammed A.
    Albdour, Muawyah D.
    CORNEA, 2012, 31 (02) : 115 - 120
  • [4] Additional Intrastromal Corneal Ring Segments in Keratoconus
    Hashemi, Hassan
    Nabavi, Amin
    Bayat, Reza
    Mohebbi, Masoumeh
    CORNEA, 2018, 37 (05) : 574 - 579
  • [5] Intrastromal corneal ring segments for management of keratoconus
    Ganesh, Sri
    Shetty, Rohit
    D'Souza, Sharon
    Ramachandran, Sarika
    Kurian, Mathew
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (08) : 451 - 455
  • [6] Decision making nomogram for intrastromal corneal ring segments in keratoconus
    Shetty, Rohit
    D'Souza, Sharon
    Ramachandran, Sarika
    Kurian, Mathew
    Nuijts, Rudy M. M. A.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (01) : 23 - 28
  • [7] Customized corneal allogenic intrastromal ring segments (CAIRS) for keratoconus with decentered asymmetric cone
    Jacob, Soosan
    Agarwal, Amar
    Awwad, Shady T.
    Mazzotta, Cosimo
    Parashar, Parnika
    Jambulingam, Sambath
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (12) : 3723 - 3729
  • [8] Adjustment of Intrastromal Corneal Ring Segments After Unsuccessful Implantation in Keratoconic Eyes
    Monteiro, Tiago
    Mendes, Jose Ferreira
    Faria-Correia, Fernando
    Franqueira, Nuno
    Madrid-Costa, David
    Alfonso, Jose F.
    CORNEA, 2018, 37 (02) : 182 - 188
  • [9] Clinical Outcomes of an Asymmetric Model of Intrastromal Corneal Ring Segments for the Correction of Keratoconus
    Prisant, Olivier
    Pottier, Elodie
    Guedj, Tony
    Xuan, Thanh Hoang
    CORNEA, 2020, 39 (02) : 155 - 160
  • [10] Efficacy of progressive thickness intrastromal corneal ring segments in the treatment of duck phenotype keratoconus
    Arbelaez, Juan G.
    Arbelaez, Maria C.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (05) : 2191 - 2199