Polypyrrole-hydrogel composites for the construction of clinically important biosensors

被引:148
作者
Brahim, S
Narinesingh, D
Guiseppi-Elie, A [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Chem Engn, Richmond, VA 23284 USA
[2] Virginia Commonwealth Univ, Ctr Bioelect Biosensors & Biochips, Richmond, VA 23284 USA
[3] Univ W Indies, Dept Chem, St Augustine, Trinidad Tobago
关键词
p(HEMA); polypyrrole; amperometric biosensor; glucose oxidase; cholesterol oxidase; galactose oxidase;
D O I
10.1016/S0956-5663(01)00262-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The present study reports on the use of p(2-hydroxyethyl methacrylate) (pHEMA) in which polypyrrole and various oxidoreductase enzymes were physically entrapped to function as a viable matrix for the construction of clinically important amperometric biosensors. Glucose oxidase. cholesterol oxidase and galactose oxidase biosensors were constructed. Electrode-supported hydrogel films were prepared by UV polymerization of the HEMA component (containing the dissolved enzyme) followed immediately by electrochemical polymerization (+ 0.7V vs. Ag/AgCl) of the pyrrole component within the interstitial spaces of the pre-formed hydrogel network. The optimized glucose oxidase biosensor displayed a wide linear glucose response range (5.0 x 10(-5) to 2.0 x 10(-2) M), a detection limit (3S(y/x)/sensitivity) of 25 muM and a response time of 35-40 s. The analytical recovery of glucose in serum samples ranged from 98 to 102% with mean coefficients of variation of 4.4% (within-day analyses) and 5.1% (day-to-day analyses). All three sensors displayed good stabilities when stored desiccated in the absence of buffer (> 9 months). (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 35 条
[1]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLY(2-HYDROXYETHYL METHACRYLATE) MEMBRANES [J].
ARICA, Y ;
HASIRCI, VN .
BIOMATERIALS, 1987, 8 (06) :489-495
[2]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .2. GLUCOSE-OXIDASE IMMOBILIZED IN POLY-N-METHYLPYRROLE [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :37-48
[3]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .5. MICROELECTRODES FOR THE DETECTION OF GLUCOSE BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN A POLY(PHENOL) FILM [J].
BARTLETT, PN ;
CARUANA, DJ .
ANALYST, 1992, 117 (08) :1287-1292
[4]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V362, P1
[5]  
BRAHIM S, 2001, IN PRESS ELECTROANAL
[6]   ENZYME CATALYSIS AT HYDROGEL-MODIFIED ELECTRODES WITH REDOX POLYMER MEDIATOR [J].
CALVO, EJ ;
DANILOWICZ, C ;
DIAZ, L .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1993, 89 (02) :377-384
[7]   Use of an enzyme thermistor for semi-continuous blood glucose measurements [J].
Carlsson, T ;
Adamson, U ;
Lins, PE ;
Danielsson, B .
CLINICA CHIMICA ACTA, 1996, 251 (02) :187-200
[8]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[9]   ELECTROCHEMICAL RESPONSE OF AN ENZYME-LOADED POLYANILINE FILM [J].
COOPER, JC ;
HALL, EAH .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (07) :473-485
[10]   SELECTIVITY OF CONDUCTING POLYMER ELECTRODES AND THEIR APPLICATION IN FLOW-INJECTION ANALYSIS OF AMINO-ACIDS [J].
COOPER, JC ;
HAMMERLE, M ;
SCHUHMANN, W ;
SCHMIDT, HL .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (01) :65-74