Variational Feedback Control for a nonlinear beam under an earthquake excitation

被引:11
|
作者
Pepe, G. [1 ]
Carcaterra, A. [1 ]
Giorgio, I. [1 ]
Del Vescovo, D. [1 ]
机构
[1] Univ Roma La Sapienza, Dept Mech & Aerosp Engn, Rome, Italy
关键词
Variational Feedback Control; Pontryagin; damping; earthquake; nonlinear; B-SPLINE INTERPOLATION; PIEZOELECTRIC TRANSDUCERS; DAMPING UNCERTAINTIES; POSTCRITICAL BEHAVIOR; NUMERICAL ALGORITHM; MECHANICAL SYSTEMS; MODEL; VIBRATIONS; CABLES; PLATES;
D O I
10.1177/1081286514562878
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The present paper reports on the application of the VFC (Variational Feedback Control) to the mitigation of the vibrational motion of continuous structures. The control method has been very recently proposed in the context of mechanical engineering to obtain suspensions characterized by better comfort performances. In this paper the same methodology is indeed applied to a simply nonlinear supported beam that is forced by a seismic excitation. The earthquake shaking, modelled as a random displacement of the beam hinges, is moderated by the presence of a controllable damper interposed between the beam and the oscillating ground, and its damping is subjected to the VFC controller. The inputs processed by the controller are the accelerations measured by two sensors, one on the ground, and the second on the beam. Numerical results are examined and some preliminary considerations are presented in which the considered method is applied to piezoelectromechanical beams.
引用
收藏
页码:1234 / 1246
页数:13
相关论文
共 50 条
  • [21] Passive optimal control of adjacent structures under earthquake excitation
    Beijing Institute of Architectural Design, Beijing 100045, China
    不详
    不详
    Proc. Int. Symp. Struct. Eng., ISSE, 1600, (1235-1243):
  • [22] ROBUST-CONTROL TECHNIQUES FOR BUILDINGS UNDER EARTHQUAKE EXCITATION
    SCHMITENDORF, WE
    JABBARI, F
    YANG, JN
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1994, 23 (05): : 539 - 552
  • [23] Finite frequency H∞ control for building under earthquake excitation
    Chen, Yang
    Zhang, Wenlong
    Gao, Huijun
    MECHATRONICS, 2010, 20 (01) : 128 - 142
  • [24] Stiffness and damping control in member structures under earthquake excitation
    Steifigkeits- und dampfungskontrolle in stabtragwerken unter erdbebenbeanspruchung
    2001, Ernst and Sohn (78)
  • [25] Fuzzy-sliding mode control of nonlinear smart base-isolated building under earthquake excitation
    Ghaffarzadeh, Hosein
    Ghaffari, Amir Hossein
    Yang, T. Y.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2019, 28 (01):
  • [26] Output-feedback sliding-mode control with generalized sliding surface for civil structures under earthquake excitation
    Dept of Engineering Sci + Mechanics, Polytechnic Inst + State Univ, Blacksburg, VA 24061, United States
    Earthquake Eng Struct Dyn, 3 (259-282):
  • [27] Output-feedback sliding-mode control with generalized sliding surface for civil structures under earthquake excitation
    Matheu, EE
    Singh, MP
    Beattie, C
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1998, 27 (03): : 259 - 282
  • [28] Optimal PID Control of a Nonlinear Composite Beam with Harmonic Excitation
    Raychaudhuri, Apratim
    Jha, Abhishek Kumar
    Dasgupta, Sovan Sundar
    ADVANCES IN POLYMER COMPOSITES: MECHANICS, CHARACTERIZATION AND APPLICATIONS, 2019, 2057
  • [29] Control of a Ball and Beam System under Intermittent Feedback
    Oh, Sang-Young
    Lee, Kyung-Tae
    Choi, Ho-Lim
    2018 18TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2018, : 56 - 61
  • [30] High static low dynamic stiffness outriggers effects on vibration control on cantilever Timoshenko Beam under earthquake excitation
    Buris Peggy Ndemanou
    A. Chéagé Chamgoué
    Guy Richard Kol
    Jules Metsebo
    SN Applied Sciences, 2021, 3