Blood Pressure - Pulse Transit Time Relationships: Comparative Studies

被引:0
|
作者
Polinski, Artur [1 ]
Bujnowski, Adam [1 ]
Kocejko, Tomasz [1 ]
Wtorek, Jerzy [1 ]
机构
[1] Gdansk Univ Technol, Fac Elect Telecommun & Informat, Biomed Engn Dept, Gdansk, Poland
来源
2020 13TH INTERNATIONAL CONFERENCE ON HUMAN SYSTEM INTERACTION (HSI) | 2020年
关键词
blood pressure; pulse transit time; approximation formulas; COMPUTER-SIMULATION; CUFF-LESS; ARTERIAL; FLOW; PARAMETERS; TUBES;
D O I
10.1109/hsi49210.2020.9142673
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A non-invasive and continuous blood pressure estimation could allow a better diagnosis and an earlier detection of various diseases. It could be performed using a photoplethysmography. However, it requires that a relation between blood pressure and pulse transit time is known. Eleven theoretical formulas were used in obtaining the simulated and noise free synthetic data. Then, they were utilized in validation of three, commonly used, formulas for blood pressure estimation. Finally, the best one was indicated.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 50 条
  • [41] Cuff-Less Continuous Blood Pressure Monitoring System Using Pulse Transit Time Techniques
    Zaki, Wan Suhaimizan Wan
    Correia, Ricardo
    Korposh, Serhiy
    Hayes-Gill, Barrie R.
    Morgan, Stephen P.
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2016, 8 (01): : 51 - 57
  • [42] Continuous blood pressure measurement using the pulse transit time: Comparison to intra-arterial measurement
    Patzak, Andreas
    Mendoza, Yuri
    Gesche, Heiko
    Konermann, Martin
    BLOOD PRESSURE, 2015, 24 (04) : 217 - 221
  • [43] Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
    Gesche, Heiko
    Grosskurth, Detlef
    Kuechler, Gert
    Patzak, Andreas
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (01) : 309 - 315
  • [44] Wearable Continuous Blood Pressure Monitoring Devices Based on Pulse Wave Transit Time and Pulse Arrival Time: A Review
    Zhou, Zi-Bo
    Cui, Tian-Rui
    Li, Ding
    Jian, Jin-Ming
    Li, Zhen
    Ji, Shou-Rui
    Li, Xin
    Xu, Jian-Dong
    Liu, Hou-Fang
    Yang, Yi
    Ren, Tian-Ling
    MATERIALS, 2023, 16 (06)
  • [45] Noninvasive Cuffless Blood Pressure Estimation Using Pulse Transit Time and Impedance Plethysmography
    Toan Huu Huynh
    Jafari, Roozbeh
    Chung, Wan-Young
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (04) : 967 - 976
  • [46] Design and Development of Pulse Transit Time Based Cuffless Blood Pressure Monitoring System
    Singh, Harinderjit
    Singh, Mandeep
    2015 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, SIGNALS, COMMUNICATION AND OPTIMIZATION (EESCO), 2015,
  • [47] The beat-to-beat relationship between pulse transit time and systolic blood pressure
    Poon, Carmen C. Y.
    Zhang, Yuan-Ting
    Wong, George
    Poon, Wai Sang
    2008 INTERNATIONAL SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, VOLS 1 AND 2, 2008, : 357 - +
  • [48] The influence of heart rate on the relationship between pulse transit time and systolic blood pressure
    Fu, Zhizhong
    Song, Xinyue
    Qin, Tianyi
    Chen, Yifan
    Ding, Xiaorong
    PHYSIOLOGICAL MEASUREMENT, 2024, 45 (10)
  • [49] Regression-forests-based Estimation of Blood Pressure using the Pulse Transit Time Obtained by Facial Photoplethysmogram
    Yoshioka, Mototaka
    Bounyong, Souksakhone
    2017 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2017, : 3248 - 3253
  • [50] Impact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation
    Ding, Xiaorong
    Zhang, Yuanting
    Tsang, Hon Ki
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (02) : 227 - 237