Blood Pressure - Pulse Transit Time Relationships: Comparative Studies

被引:0
|
作者
Polinski, Artur [1 ]
Bujnowski, Adam [1 ]
Kocejko, Tomasz [1 ]
Wtorek, Jerzy [1 ]
机构
[1] Gdansk Univ Technol, Fac Elect Telecommun & Informat, Biomed Engn Dept, Gdansk, Poland
来源
2020 13TH INTERNATIONAL CONFERENCE ON HUMAN SYSTEM INTERACTION (HSI) | 2020年
关键词
blood pressure; pulse transit time; approximation formulas; COMPUTER-SIMULATION; CUFF-LESS; ARTERIAL; FLOW; PARAMETERS; TUBES;
D O I
10.1109/hsi49210.2020.9142673
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A non-invasive and continuous blood pressure estimation could allow a better diagnosis and an earlier detection of various diseases. It could be performed using a photoplethysmography. However, it requires that a relation between blood pressure and pulse transit time is known. Eleven theoretical formulas were used in obtaining the simulated and noise free synthetic data. Then, they were utilized in validation of three, commonly used, formulas for blood pressure estimation. Finally, the best one was indicated.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 50 条
  • [31] A Linear Regression Model with Dynamic Pulse Transit Time Features for Noninvasive Blood Pressure Prediction
    Hsieh, Yi-Yen
    Wu, Ching-Da
    Lu, Shey-Shi
    Tsao, Yu
    PROCEEDINGS OF 2016 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2016, : 604 - 607
  • [32] Towards Ubiquitous Blood Pressure Monitoring in an Armband using Pulse Transit Time
    Toreyin, Hakan
    Javaid, Abdul Q.
    Ashouri, Hazar
    Ode, Oludotun
    Inan, Omer T.
    2015 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2015, : 560 - 563
  • [33] Blood Pressure Measurement from Photo-plethysmography to Pulse Transit Time
    Myint, C. Z.
    Lim, King Hann
    Wong, Kiing Ing
    Gopalai, Alpha Agape
    Oo, Min Zin
    2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2014, : 496 - 501
  • [34] Pulse transit time: validation of blood pressure measurement under positive airway pressure ventilation
    Schmalgemeier, Heidi
    Bitter, Thomas
    Bartsch, Stephan
    Bullert, Kevin
    Fischbach, Thomas
    Eckert, Siegfried
    Horstkotte, Dieter
    Oldenburg, Olaf
    SLEEP AND BREATHING, 2012, 16 (04) : 1105 - 1112
  • [35] Pulse transit time: validation of blood pressure measurement under positive airway pressure ventilation
    Heidi Schmalgemeier
    Thomas Bitter
    Stephan Bartsch
    Kevin Bullert
    Thomas Fischbach
    Siegfried Eckert
    Dieter Horstkotte
    Olaf Oldenburg
    Sleep and Breathing, 2012, 16 : 1105 - 1112
  • [36] Modeling of pulse transit time under the effects of hydrostatic pressure for cuffless blood pressure measurements
    Poon, Carmen C. Y.
    Zhang, Yuan-Ting
    Liu, Yinbo
    2006 3RD IEEE/EMBS INTERNATIONAL SUMMER SCHOOL ON MEDICAL DEVICES AND BIOSENSORS, 2006, : 65 - +
  • [37] An examination of calibration intervals required for accurately tracking blood pressure using pulse transit time algorithms
    McCarthy, B. M.
    Vaughan, C. J.
    O'Flynn, B.
    Mathewson, A.
    Mathuna, C. O.
    JOURNAL OF HUMAN HYPERTENSION, 2013, 27 (12) : 744 - 750
  • [38] Continuous Non-Invasive Blood Pressure Measurement Using Pulse Transit Time in Children and Adolescents
    Zagrada, Elena
    Krickau, Tobias
    Rascher, Wolfgang
    KLINISCHE PADIATRIE, 2019, 231 (02): : 67 - 73
  • [39] An examination of calibration intervals required for accurately tracking blood pressure using pulse transit time algorithms
    B M McCarthy
    C J Vaughan
    B O'Flynn
    A Mathewson
    C Ó Mathúna
    Journal of Human Hypertension, 2013, 27 : 744 - 750
  • [40] Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
    Heiko Gesche
    Detlef Grosskurth
    Gert Küchler
    Andreas Patzak
    European Journal of Applied Physiology, 2012, 112 : 309 - 315