Optical Coherence Tomography Evaluation in the Multicenter Uveitis Steroid Treatment (MUST) Trial

被引:10
作者
Domalpally, Amitha [1 ]
Altaweel, Michael M. [1 ]
Kempen, John H. [2 ,3 ]
Myers, Dawn [1 ]
Davis, Janet L. [4 ]
Foster, C. Stephen [5 ,6 ]
Latkany, Paul [7 ]
Srivastava, Sunil K. [8 ]
Stawell, Richard J. [9 ]
Holbrook, Janet T. [10 ,11 ]
机构
[1] Univ Wisconsin, Dept Ophthalmol & Visual Sci, Fundus Photograph Reading Ctr, Madison, WI 53715 USA
[2] Univ Penn, Scheie Eye Inst, Dept Ophthalmol, Dept Biostat & Epidemiol, Philadelphia, PA 19104 USA
[3] Univ Penn, Ctr Clin Epidemiol & Biostat, Philadelphia, PA 19104 USA
[4] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Dept Ophthalmol, Miami, FL 33136 USA
[5] Massachusetts Eye Res & Surg Inst, Cambridge, MA USA
[6] Harvard Univ, Sch Med, Boston, MA USA
[7] New York Eye & Ear Infirm, New York, NY 10003 USA
[8] Emory Univ, Dept Ophthalmol, Atlanta, GA 30322 USA
[9] Royal Victorian Eye & Ear Hosp, Ocular Immunol Clin, Melbourne, Australia
[10] Johns Hopkins Univ, Bloomberg Sch Publ Hlth, Ctr Clin Trials, Baltimore, MD USA
[11] Johns Hopkins Univ, Bloomberg Sch Publ Hlth, Dept Epidemiol, Baltimore, MD USA
关键词
Optical coherence tomography; OCT; Uveitis; Macular edema; Retinal thickness; VEIN-OCCLUSION SCORE; MACULAR EDEMA SECONDARY; STANDARD-CARE; INTRAVITREAL TRIAMCINOLONE; EFFICACY; SAFETY;
D O I
10.3109/09273948.2012.719258
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe the evaluation of optical coherence tomography (OCT) scans in the Muliticenter Uveitis Steroid Treatment (MUST) trial and report baseline OCT features of enrolled participants. Methods: Time-domain OCTs acquired by certified photographers using a standardized scan protocol were evaluated at a reading center. Accuracy of retinal thickness data was confirmed with quality evaluation, and caliper measurement of centerpoint thickness (CPT) was performed when retinal thickness data were unreliable. Morphological evaluation included cysts, subretinal fluid, epiretinal membranes (ERMs), and vitreomacular traction. Results: Of the 453 OCTs evaluated, automated retinal thickness was accurate in 69.5% of scans, caliper measurement was performed in 26%, and 4% were ungradable. Intraclass correlation was. 98 for reproducibility of caliper measurement. Macular edema (centerpoint thickness >= 240 mu m) was present in 36%. Cysts were present in 36.6% of scans and ERMs in 27.8%, predominantly central. Intergrader agreement ranged from 78 to 82% for morphological features. Conclusion: Retinal thickness data can be retrieved in a majority of OCT scans in clinical trial submissions for uveitis studies. Small cysts and ERMs involving the center are common in intermediate and posterior/panuveitis requiring systemic corticosteroid therapy.
引用
收藏
页码:443 / 447
页数:5
相关论文
共 18 条
[1]  
[Anonymous], 1991, Ophthalmology, V98, P786
[2]   Ultrastructural correlation of spectral-domain optical coherence tomographic findings in Vitreomacular Traction syndrome [J].
Chang, Louis K. ;
Fine, Howard F. ;
Spaide, Richard F. ;
Koizumi, Hideki ;
Grossniklaus, Hans E. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (01) :121-127
[3]   Comparison of time-domain OCT and fundus photographic assessments of retinal thickening in eyes with diabetic macular edema [J].
Davis, Matthew D. ;
Bressler, Susan B. ;
Aiello, Lloyd Paul ;
Bressler, Neil M. ;
Browning, David J. ;
Flaxel, Christina J. ;
Fong, Donald S. ;
Foster, William J. ;
Glassman, Adam R. ;
Hartnett, Mary Elizabeth R. ;
Kollman, Craig ;
Li, Helen K. ;
Qin, Haijing ;
Scott, Ingrid U. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (05) :1745-1752
[4]  
Domalpally Amitha, 2010, Ophthalmic Surg Lasers Imaging, V41 Suppl, pS34, DOI 10.3928/15428877-20100325-01
[5]   The Standard Care vs Corticosteroid for Retinal Vein Occlusion (SCORE) Study System for Evaluation of Optical Coherence Tomograms SCORE Study Report 4 [J].
Domalpally, Amitha ;
Blodi, Barbara A. ;
Scott, Ingrid U. ;
Ip, Michael S. ;
Oden, Neal L. ;
Lauer, Andreas K. ;
VanVeldhuisen, Paul C. .
ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (11) :1461-1467
[6]   QUALITY ISSUES IN INTERPRETATION OF OPTICAL COHERENCE TOMOGRAMS IN MACULAR DISEASES [J].
Domalpally, Amitha ;
Danis, Ronald P. ;
Zhang, Baoyan ;
Myers, Dawn ;
Kruse, Christina N. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (06) :775-781
[7]   An optical coherence tomography-guided, variable dosing regimen with intravitreal ranibizumab (lucentis) for neovascular age-related macular degeneration [J].
Fung, Anne E. ;
Lalwani, Geeta A. ;
Rosenfeld, Philip J. ;
Dubovy, Sander R. ;
Michels, Stephan ;
Feuer, William J. ;
Puliafito, Carmen A. ;
Davis, Janet L. ;
Flynn, Harry W., Jr. ;
Esquiabro, Maria .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (04) :566-583
[8]   Comparison of Optical Coherence Tomography in Diabetic Macular Edema, with and without Reading Center Manual Grading from a Clinical Trials Perspective [J].
Glassman, Adam R. ;
Beck, Roy W. ;
Browning, David J. ;
Danis, Ronald P. ;
Kollman, Craig .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (02) :560-566
[9]   Spectral-domain cirrus high-definition optical coherence tomography is better than time-domain stratus optical coherence tomography for evaluation of macular pathologic features in uveitis [J].
Gupta, Vishali ;
Gupta, Pawan ;
Singh, Ramandeep ;
Dogra, Mangat R. ;
Gupta, Amod .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (06) :1018-1022
[10]   Evaluation of Artifacts Associated with Macular Spectral-Domain Optical Coherence Tomography [J].
Han, Ian C. ;
Jaffe, Glenn J. .
OPHTHALMOLOGY, 2010, 117 (06) :1177-U211