An approach to enhancing coverage of the urinary metabonome using liquid chromatography-ion mobility-mass spectrometry

被引:43
作者
Harry, Emma L. [1 ]
Weston, Daniel J. [2 ]
Bristow, Anthony W. T. [3 ]
Wilson, Ian D. [4 ]
Creaser, Colin S. [1 ]
机构
[1] Loughborough Univ Technol, Dept Chem, Loughborough LE11 3TU, Leics, England
[2] AstraZeneca R&D Charnwood, Clin Pharmacol & DMPK, Loughborough LE11 5RH, Leics, England
[3] AstraZeneca, Macclesfield SK10 2NA, Cheshire, England
[4] AstraZeneca, Macclesfield SK10 4TF, Cheshire, England
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2008年 / 871卷 / 02期
关键词
ion mobility-mass spectrometry; reversed-phase HPLC; metabonomics; urinary metabolome;
D O I
10.1016/j.jchromb.2008.04.043
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The potential of drift tube ion mobility (IM) spectrometry in combination with high performance liquid chromatography (LC) and mass spectrometry (MS) for the metabonomic analysis of rat urine is reported. The combined LC-IM-MS approach using quadrupole/time-of-flight mass spectrometry with electrospray ionisation, uses gas-phase analyte characterisation based on both mass-to-charge (m/z) ratio and relative gas-phase mobility (drift time) following LC separation. The technique allowed the acquisition of nested data sets, with mass spectra acquired at regular intervals (65 mu s) during each IMS separation (similar to 13 ms) and several IMS spectra acquired during the elution of a single LC peak, without increasing the overall analysis time compared to LC-MS. preliminary results indicate that spectral quality is improved when using LC-IM-MS, compared to direct injection IM-MS. for which significant ion suppression effects were observed in the electrospray ion source. The use of reversed-phase LC employing fast gradient elution reduced sample preparation to a minimum, whilst maintaining the potential for high throughput analysis. Data mining allowed information on specific analytes to be extracted from the complex metabonomic data set. LC-IM-MS based approaches may have a useful role in metabonomic analyses by introducing an additional discriminatory dimension of ion mobility (drift time). (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:357 / 361
页数:5
相关论文
共 25 条
[1]  
[Anonymous], 2005, ION MOBILITY SPECTRO, DOI [DOI 10.1201/9781420038972, DOI 10.1016/j.ijms.2010.09.009]
[2]   Pretreatment of mass spectral profiles: Application to proteomic data [J].
Arneberg, Reidar ;
Rajalahti, Tarja ;
Flikka, Kristian ;
Berven, Frode S. ;
Kroksveen, Ann C. ;
Berle, Magnus ;
Myhr, Kjell-Morten ;
Vedeler, Christian A. ;
Ulvik, Rune J. ;
Kvalheim, Olav M. .
ANALYTICAL CHEMISTRY, 2007, 79 (18) :7014-7026
[3]  
Bishop CM., 1995, Neural networks for pattern recognition
[4]   NMR-based metabolic profiling and metabonomic approaches to problems in molecular toxicology [J].
Coen, Muireann ;
Holmes, Elaine ;
Lindon, John C. ;
Nicholson, Jeremy K. .
CHEMICAL RESEARCH IN TOXICOLOGY, 2008, 21 (01) :9-27
[5]   Ion mobility spectrometry: a review. Part 1. Structural analysis by mobility measurement [J].
Creaser, CS ;
Griffiths, JR ;
Bramwell, CJ ;
Noreen, S ;
Hill, CA ;
Thomas, CLP .
ANALYST, 2004, 129 (11) :984-994
[6]   Metabolic profiling by ion mobility mass spectrometry (IMMS) [J].
Dwivedi, Prabha ;
Wu, Peiying ;
Klopsch, Steve J. ;
Puzon, Geoffrey J. ;
Xun, Luying ;
Hill, Herbert H., Jr. .
METABOLOMICS, 2008, 4 (01) :63-80
[7]  
HOMES E, 2002, ANALYST, V127, P1549
[8]   Ion mobility-mass spectrometry [J].
Kanu, Abu B. ;
Dwivedi, Prabha ;
Tam, Maggie ;
Matz, Laura ;
Hill, Herbert H., Jr. .
JOURNAL OF MASS SPECTROMETRY, 2008, 43 (01) :1-22
[9]   Pharmaceutical applications of liquid chromatography coupled with mass spectrometry (LC/MS) [J].
Lee, H .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (7-8) :1161-1202
[10]   Analytical strategies in metabonomics [J].
Lenz, Eva Maria ;
Wilson, Ian D. .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (02) :443-458