Multiplexed immunoassay: Quantitation and profiling of serum biomarkers using magnetic nanoprobes and MALDI-TOF MS

被引:72
作者
Wang, Kai-Yi [2 ,3 ]
Chuang, Szu-An [2 ,3 ]
Lin, Po-Chiao [1 ,2 ,4 ]
Huang, Li-Shing [2 ]
Chen, Shu-Hua [2 ,5 ]
Ouarda, Saib [2 ]
Pan, Wen-Harn [6 ]
Lee, Ping-Ying [7 ]
Lin, Chun-Cheng [1 ,4 ,8 ]
Chen, Yu-Ju [2 ,4 ,5 ,8 ]
机构
[1] Natl Tsing Hua Univ, Dept Chem, Hsinchu, Taiwan
[2] Acad Sinica, Inst Chem, Taipei 115, Taiwan
[3] Natl Cent Univ, Dept Chem, Tao Yuan, Taiwan
[4] Acad Sinica, Taiwan Int Grad Program, Taipei 115, Taiwan
[5] Natl Taiwan Univ, Dept Chem, Taipei 10764, Taiwan
[6] Acad Sinica, Inst Biomed Sci, Taipei, Taiwan
[7] Mackay Mem Hosp, Nursing & Management Coll, Dept Internal Med, Div Cardiol, Taipei, Taiwan
[8] Acad Sinica, Ctr Gene Res, Taipei 115, Taiwan
关键词
D O I
10.1021/ac800354u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Taking advantage of efficient affinity extraction by surface-functionalized magnetic nanoparticles (MNPs) and accurate MALDI-TOF MS readout, we present a multiplexed immunoassay for simultaneous enrichment and quantitation of multiple disease-associated antigens, serum amyloid A (SAA), C-reactive protein (CRP), and serum amyloid P (SAP) from human serum. To obtain reproducible MALDI signal response with direct on-MNP detection, the seed-layer method improved homogeneity of the cocrystallization of MNPs and captured antigens. Our methodology demonstrated good quantitation linearity of targeted analytes (R-2 approximate to 0.97) with reduced signal variation (RSD < 10%). The lower limit of quantitation is in the nanogram level with overall assay precision (intraday, 7.0%; interday, 11.3%) and accuracy (intraday, 6.3%; interday, 17.5%) including steps of nanoprobe extraction and MALDI-TOF MS analysis. This triplexed immunoassay showed overexpression of SAA and CRP in patients with cardiac catheterization or gastric cancer (P < 0.05), consistent with single-analyte ELISA and previous studies. Compared to the determination of disease onset by single protein quantitation, our multiplexed immunoassay revealed a distinct triplexed pattern in the control group, patients with gastric cancer, and cardiac catheterization. On the basis of the advantages of flexibility in nanoprobe preparation, high specificity and sensitivity, and rapid screening by MALDI-TOF MS, this platform may provide a new methodology for disease diagnosis.
引用
收藏
页码:6159 / 6167
页数:9
相关论文
共 48 条
  • [1] Preparation of DNA and protein micro arrays on glass slides coated with an agarose film
    Afanassiev, Victor
    Hanemann, Vera
    Woelfl, Stefan
    [J]. NUCLEIC ACIDS RESEARCH, 2000, 28 (12) : E66
  • [2] [Anonymous], 1996, GUIDANCE IND Q2B VAL
  • [3] SERUM AMYLOID-A (SAA) VARIATIONS IN PATIENTS WITH CANCER - CORRELATION WITH DISEASE-ACTIVITY, STAGE, PRIMARY SITE, AND PROGNOSIS
    BIRAN, H
    FRIEDMAN, N
    NEUMANN, L
    PRAS, M
    SHAINKINKESTENBAUM, R
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1986, 39 (07) : 794 - 797
  • [4] Evaluation of serum amyloid A as a biomarker for gastric cancer
    Chan, De-Chuan
    Chen, Cheng-Jueng
    Chu, Heng-Cheng
    Chang, Wei-Kuo
    Yu, Jyh-Cherng
    Chen, Yu-Ju
    Wen, Li-Li
    Huang, Su-Ching
    Ku, Chih-Hung
    Liu, Yao-Chi
    Chen, Jenn-Han
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2007, 14 (01) : 84 - 93
  • [5] Targeted protein quantitation and profiling using PVDF affinity probe and MALDI-TOF MS
    Chen, Shu-Hua
    Liao, Hsin-Kai
    Chang, Chih-Yang
    Ju, Chiun-Gung
    Chen, Jenn-Han
    Chan, Sunney I.
    Chen, Yu-Ju
    [J]. PROTEOMICS, 2007, 7 (17) : 3038 - 3050
  • [6] Nanoprobe-based affinity mass spectrometry for selected protein profiling in human plasma
    Chou, PH
    Chen, SH
    Liao, HK
    Lin, PC
    Her, GR
    Lai, ACY
    Chen, JH
    Lin, CC
    Chen, YJ
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (18) : 5990 - 5997
  • [7] Lab-on-a-chip: microfluidics in drug discovery
    Dittrich, PS
    Manz, A
    [J]. NATURE REVIEWS DRUG DISCOVERY, 2006, 5 (03) : 210 - 218
  • [8] Protein concentration and enzyme digestion on microbeads for MALDI-TOF peptide mass mapping of proteins from dilute solutions
    Doucette, A
    Craft, D
    Li, L
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (14) : 3355 - 3362
  • [9] The case for early detection
    Etzioni, R
    Urban, N
    Ramsey, S
    McIntosh, M
    Schwartz, S
    Reid, B
    Radich, J
    Anderson, G
    Hartwell, L
    [J]. NATURE REVIEWS CANCER, 2003, 3 (04) : 243 - 252
  • [10] Identification and validation of a potential lung cancer serum biomarker detected by matrix-assisted laser desorption/ionization-time of flight spectra analysis
    Howard, BA
    Wang, MZ
    Campa, MJ
    Corro, C
    Fitzgerald, MC
    Patz, EF
    [J]. PROTEOMICS, 2003, 3 (09) : 1720 - 1724