Volume load paradox while preparing for the Fontan: not too much for the ventricle, not too little for the lungs

被引:48
作者
Gewillig, Marc [1 ]
Brown, Stephen C.
Heying, Ruth [1 ]
Eyskens, Benedicte [1 ]
Ganame, Javier [1 ]
Boshoff, Derize E. [1 ]
Budts, Werner [1 ]
Gorenflo, Matthias [1 ]
机构
[1] Katholieke Univ Leuven Hosp, B-3000 Louvain, Belgium
关键词
Univentricular heart; Fontan circulation; Cavo pulmonary connection; Palliation; Growth and resistance pulmonary arteries;
D O I
10.1510/icvts.2009.218586
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ventricular dysfunction is frequently encountered in Fontan patients. Cardiologists and cardiac surgeons have, therefore, mainly focused on preservation of cardiac function, limiting the early volume overload as much as possible both in magnitude and duration. This resulted in improved cardiac function but, in some patients, also in poor pulmonary artery (PA) growth which in turn resulted in a poor final Fontan circuit. The volume requirements for optimal growth and development of the ventricle and the lungs are different and divergent. Avoiding overload of the ventricle is important, but excessive protection from volume overload may not be necessary and may result in PA hypoplasia, which in turn will severely affect the Fontan circuit. (c) 2010 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.
引用
收藏
页码:262 / 265
页数:4
相关论文
共 36 条
  • [11] 5-YEAR TO 15-YEAR FOLLOW-UP AFTER FONTAN OPERATION
    DRISCOLL, DJ
    OFFORD, KP
    FELDT, RH
    SCHAFF, HV
    PUGA, FJ
    DANIELSON, GK
    [J]. CIRCULATION, 1992, 85 (02) : 469 - 496
  • [12] Fagard Robert H., 1997, Cardiology Clinics, V15, P397
  • [13] FONTAN F, 1989, J THORAC CARDIOV SUR, V98, P711
  • [14] SURGICAL REPAIR OF TRICUSPID ATRESIA
    FONTAN, F
    BAUDET, E
    [J]. THORAX, 1971, 26 (03) : 240 - +
  • [15] LEFT-VENTRICULAR COMPLIANCE - MECHANISMS AND CLINICAL IMPLICATIONS
    GAASCH, WH
    LEVINE, HJ
    QUINONES, MA
    ALEXANDER, JK
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1976, 38 (05) : 645 - 653
  • [16] Stenting the neonatal arterial duct in duct-dependent pulmonary circulation: New techniques, better results
    Gewillig, M
    Boshoff, DE
    Dens, J
    Mertens, L
    Benson, LN
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (01) : 107 - 112
  • [17] GEWILLIG M, 1992, CIRCULATION, V86, P93
  • [18] Gewillig M, 1994, Semin Thorac Cardiovasc Surg, V6, P56
  • [19] Pathophysiological aspects after cavopulmonary anastomosis
    Gewillig, M
    Kalis, N
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 2000, 48 (06) : 336 - 341
  • [20] Ventricular dysfunction of the functionally univentricular heart: management and outcomes
    Gewillig, Marc
    [J]. CARDIOLOGY IN THE YOUNG, 2005, 15 : 31 - 34