Fat suppression strategies in MR imaging of breast cancer at 3.0 T: comparison of the two-point Dixon technique and the frequency selective inversion method

被引:6
作者
Mikami, Wakako Kaneko [1 ]
Kazama, Toshiki [1 ]
Sato, Hirotaka [2 ]
Yokota, Hajime [1 ]
Higashide, Takashi [1 ]
Horikoshi, Takuro [1 ]
Motoori, Ken [1 ]
Miyazawa, Yukimasa [3 ]
Nagashima, Takeshi [4 ]
Uno, Takashi [1 ]
机构
[1] Chiba Univ, Grad Sch Med, Dept Diagnost Radiol & Radiat Oncol, Chuo Ku, Chiba 2608670, Japan
[2] Chiba Univ Hosp, Dept Radiol, Chuo Ku, Chiba 2608677, Japan
[3] Chiba Univ, Grad Sch Med, Dept Frontier Surg, Chuo Ku, Chiba 2608670, Japan
[4] Chiba Univ, Grad Sch Med, Dept Gen Surg, Chuo Ku, Chiba 2608670, Japan
关键词
3.0 T MRI; Fat suppression; Two-point Dixon technique; T1-weighted contrast agent enhancement; Breast imaging; CONTRAST-ENHANCED MRI; ECHO; MAMMOGRAPHY; SEQUENCES; ACCURACY; RECOVERY; NODES; WATER;
D O I
10.1007/s11604-013-0230-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare two fat suppression methods in contrast-enhanced MR imaging of breast cancer at 3.0 T: the two-point Dixon method and the frequency selective inversion method. Forty female patients with breast cancer underwent contrast-enhanced three-dimensional T1-weighted MR imaging at 3.0 T. Both the two-point Dixon method and the frequency selective inversion method were applied. Quantitative analyses of the residual fat signal-to-noise ratio and the contrast noise ratio (CNR) of lesion-to-breast parenchyma, lesion-to-fat, and parenchyma-to-fat were performed. Qualitative analyses of the uniformity of fat suppression, image contrast, and the visibility of breast lesions and axillary metastatic adenopathy were performed. The signal-to-noise ratio was significantly lower in the two-point Dixon method (P < 0.001). All CNR values were significantly higher in the two-point Dixon method (P < 0.001 and P = 0.001, respectively). According to qualitative analysis, both the uniformity of fat suppression and image contrast with the two-point Dixon method were significantly higher (P < 0.001 and P = 0.002, respectively). Visibility of breast lesions and metastatic adenopathy was significantly better in the two-point Dixon method (P < 0.001 and P = 0.03, respectively). The two-point Dixon method suppressed the fat signal more potently and improved contrast and visibility of the breast lesions and axillary adenopathy.
引用
收藏
页码:615 / 622
页数:8
相关论文
共 27 条
[1]   Origin of a signal intensity loss artifact in fat-saturation MR imaging [J].
Axel, L ;
Kolman, L ;
Charafeddine, R ;
Hwang, SN ;
Stolpen, AH .
RADIOLOGY, 2000, 217 (03) :911-915
[2]   Application of MR Mammography Beyond Local Staging: Is There a Potential to Accurately Assess Axillary Lymph Nodes? Evaluation of an Extended Protocol in an Initial Prospective Study [J].
Baltzer, Pascal A. T. ;
Dietzel, Matthias ;
Burmeister, Hartmut P. ;
Zoubi, Ramy ;
Gajda, Mieczyslaw ;
Camara, Oumar ;
Kaiser, Werner A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (05) :W641-W647
[3]   Two-point Dixon Method With Flexible Echo Times [J].
Berglund, Johan ;
Ahlstroem, Hakan ;
Johansson, Lars ;
Kullberg, Joel .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) :994-1004
[4]   MR IMAGING - CLINICAL USE OF THE INVERSION RECOVERY SEQUENCE [J].
BYDDER, GM ;
YOUNG, IR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :659-675
[5]   Pelvic imaging using a T1W fat-suppressed three-dimensional dual echo dixon technique at 3T [J].
Cornfeld, Daniel M. ;
Israel, Gary ;
McCarthy, Shirley M. ;
Weinreb, Jeffery C. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (01) :121-127
[6]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[7]   T1-Weighted 3D Dynamic Contrast-Enhanced MRI of the Breast Using a Dual-Echo Dixon Technique at 3 T [J].
Dogan, Basak E. ;
Ma, Jingfei ;
Hwang, Ken ;
Liu, Ping ;
Yang, Wei Tse .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (04) :842-851
[8]   Increasing Accuracy of Detection of Breast Cancer with 3-T MRI [J].
Elsamaloty, Haitham ;
Elzawawi, Mohamed Salah ;
Mohammad, Shaden ;
Herial, Nabeel .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) :1142-1148
[9]   INVERSION IN THE STEADY-STATE - CONTRAST OPTIMIZATION AND REDUCED IMAGING TIME WITH FAST 3-DIMENSIONAL INVERSION-RECOVERY - PREPARED GRE PULSE SEQUENCES [J].
FOO, TKF ;
SAWYER, AM ;
FAULKNER, WH ;
MILLS, DG .
RADIOLOGY, 1994, 191 (01) :85-90
[10]   CHEMICAL-SHIFT SELECTIVE MR IMAGING USING A WHOLE-BODY MAGNET [J].
FRAHM, J ;
HAASE, A ;
HANICKE, W ;
MATTHAEI, D ;
BOMSDORF, H ;
HELZEL, T .
RADIOLOGY, 1985, 156 (02) :441-444