Transcranial Doppler with Bubble Study as a Method to Detect Extracardiac Right-to-Left Shunts in Patients with Ischemic Stroke

被引:10
作者
Goutman, Stephen A. [1 ]
Katzan, Irene L. [1 ]
Gupta, Rishi [2 ]
机构
[1] Cleveland Clin Fdn, Cerebrovasc Ctr, Cleveland, OH USA
[2] Emory Univ, Marcus Stroke & Neurosci Ctr, Grady Mem Hosp, Dept Neurol,Sch Med, Atlanta, GA 30303 USA
关键词
Transcranial doppler; cryptogenic stroke; shunting; ULTRASOUND;
D O I
10.1111/j.1552-6569.2012.00738.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSEParadoxical embolism through extracardiac right-to-left shunts (ECRLS) may represent an under-detected stroke mechanism. Stroke patients without evidence of cardiac right-to-left shunt (RLS) on echocardiogram may benefit from transcranial Doppler with bubble study (TCD-b) to aid in recognition of stroke etiology. This study assesses the usefulness of TCD-b in the stroke evaluation. METHODSRetrospective cohort study of consecutive patients undergoing TCD-b performed in our neurovascular laboratory from February 2005 to August 2009. Echocardiography results were reviewed in patients with positive TCD-b. Detailed medical record review was performed on patients with positive TCD-b and negative echocardiogram findings for RLS. RESULTSOf 502 patients undergoing TCD-b, 48.4% (n = 243) had a positive study suggesting the presence of RLS. Of these, 59.2% (n = 144) had an echocardiogram demonstrating a cardiac RLS, 26% (n = 63) had echocardiograms without evidence of cardiac RLS, and 14.8% (n = 36) had no echocardiogram. Data on the evaluation to determine source of potential shunting in patients with discrepant findings was available in 11(17.5%). Of these, 63.6% (7/11) had potential mechanisms for positive TCD-b: one pulmonary arteriovenous malformation (AVM), one arteriovenous fistula thrombus, one parietal AVM, and four had malignancy. CONCLUSIONSTCD-bubble studies may prove useful in uncovering treatable causes of stroke.
引用
收藏
页码:523 / 525
页数:3
相关论文
共 13 条
[1]   Effects of Posture on Right-to-Left Shunt Detection by Contrast Transcranial Doppler [J].
Agustin, Sherwin Joy U. ;
Yumul, Maricar P. ;
Kalaw, Angelito Jonas L. ;
Teo, Boon Choon ;
Eng, Johnny ;
Ziqun Phua ;
Singh, Rajinder ;
Gan, Robert N. ;
Venketasubramanian, Narayanaswamy .
STROKE, 2011, 42 (08) :2201-2205
[2]   Frequency and mechanisms of stroke recurrence after cryptogenic stroke [J].
Bang, OY ;
Lee, PH ;
Joo, SY ;
Lee, JS ;
Joo, IS ;
Huh, K .
ANNALS OF NEUROLOGY, 2003, 54 (02) :227-234
[3]   Almost perfect concordance between simultaneous transcranial Doppler and transesophageal echocardiography in the quantification of right-to-left shunts [J].
Belvís, R ;
Leta, RG ;
Martí-Fàbregas, J ;
Cocho, D ;
Carreras, F ;
Pons-Lladó, G ;
Martí-Vilalta, JL .
JOURNAL OF NEUROIMAGING, 2006, 16 (02) :133-138
[4]   TRANSCRANIAL DOPPLER ULTRASOUND IDENTIFIES PATIENTS WITH RIGHT-TO-LEFT CARDIAC OR PULMONARY SHUNTS [J].
CHIMOWITZ, MI ;
NEMEC, JJ ;
MARWICK, TH ;
LORIG, RJ ;
FURLAN, AJ ;
SALCEDO, EE .
NEUROLOGY, 1991, 41 (12) :1902-1904
[5]   Case report - Pulmonary arteriovenous fistulas developed after chemotherapy of metastatic choriocarcinoma [J].
Choi, SH ;
Goo, JM ;
Kim, HC ;
Im, JG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (06) :1544-1546
[6]   Ischaemic stroke with malignancy may often be caused by paradoxical embolism [J].
Iguchi, Y. ;
Kimura, K. ;
Kobayashi, K. ;
Ueno, Y. ;
Inoue, T. .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2006, 77 (12) :1336-1339
[7]   Contrast Transcranial Doppler Can Diagnose Large Patent Foramen Ovale [J].
Kobayashi, Kazuto ;
Iguchi, Yasuyuki ;
Kimura, Kazumi ;
Okada, Yoko ;
Terasawa, Yuka ;
Matsumoto, Noriko ;
Sakai, Kenichirou ;
Aoki, Jyunya ;
Shibazaki, Kensaku .
CEREBROVASCULAR DISEASES, 2009, 27 (03) :230-234
[8]   Effect of body positioning during transcranial Doppler detection of right-to-left shunts [J].
Lao, A. Y. ;
Sharma, V. K. ;
Tsivgoulis, G. ;
Malkoff, M. D. ;
Alexandrov, A. V. ;
Frey, J. L. .
EUROPEAN JOURNAL OF NEUROLOGY, 2007, 14 (09) :1035-1039
[9]   INFARCTS OF UNDETERMINED CAUSE - THE NINCD STROKE DATA-BANK [J].
SACCO, RL ;
ELLENBERG, JH ;
MOHR, JP ;
TATEMICHI, TK ;
HIER, DB ;
PRICE, TR ;
WOLF, PA .
ANNALS OF NEUROLOGY, 1989, 25 (04) :382-390
[10]   Is transcranial Doppler for the detection of venous-to-arterial circulation shunts reproducible? [J].
Sastry, S. ;
Daly, K. ;
Chengodu, T. ;
McCollum, C. .
CEREBROVASCULAR DISEASES, 2007, 23 (5-6) :424-429