Evaluation of imaging performance of a taper optics CCD 'FReLoN' camera designed for medical imaging

被引:85
作者
Coan, P
Peterzol, A
Fiedler, S
Ponchut, C
Labiche, JC
Bravin, A
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble 9, France
[2] Univ Trieste, Dipartimento Fis, I-34100 Trieste, Italy
[3] Ist Nazl Fis Nucl, Sez Trieste, I-34100 Trieste, Italy
[4] EMBL, D-22603 Hamburg, Germany
关键词
medical imaging; image detectors; image quality;
D O I
10.1107/S0909049506008983
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The purpose of this work was to assess the imaging performance of an indirect conversion detector (taper optics CCD 'FReLoN' camera) in terms of the modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Measurements were made with a synchrotron radiation laminar beam at various monochromatic energies in the 20-51.5 keV range for a gadolinium-based fluorescent screen varying in thickness; data acquisition and analysis were made by adapting to this beam geometry protocols used for conventional cone beams. The presampled MTFs of the systems were measured using an edge method. The NNPS of the systems were determined for a range of exposure levels by two-dimensional Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, NNPS, exposure and incoming number of photons. The MTF, for a given screen, was found to be almost energy independent and, for a given energy, higher for the thinnest screen. At 33 keV and for the 40 ( 100) mm screen, at 10% the MTF is 9.2 (8.6) line-pairs mm(-1). The NNPS was found to be different in the two analyzed directions in relation to frequency. Highest DQE values were found for the combination 100 mm and 25 keV (0.5); it was still equal to 0.4 at 51.5 keV ( above the gadolinium K-edge). The DQE is limited by the phosphor screen conversion yield and by the CCD efficiency. At the end of the manuscript the results of the FReLoN characterization and those from a selected number of detectors presented in the literature are compared.
引用
收藏
页码:260 / 270
页数:11
相关论文
共 34 条
[1]   High-resolution blood-brain barrier permeability and blood volume imaging using quantitative synchrotron radiation computed tomography:: study on an F98 rat brain glioma [J].
Adam, JF ;
Nemoz, C ;
Bravin, A ;
Fiedler, S ;
Bayat, S ;
Monfraix, S ;
Berruyer, G ;
Charvet, AM ;
Le Bas, JF ;
Elleaume, H ;
Estève, F .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2005, 25 (02) :145-153
[2]   Mammography with synchrotron radiation: Phase-detection techniques [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Fabrizioli, M ;
Longo, R ;
Menk, RH ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Ratti, M ;
Rigon, L ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
RADIOLOGY, 2000, 215 (01) :286-293
[3]  
*ATM, 2002, FULL FIELD CD IM SEN
[4]   Comparison of synchrotron radiation angiography with conventional angiography for the diagnosis of in-stent restenosis after percutaneous transluminal coronary angioplasty [J].
Bertrand, B ;
Estève, F ;
Elleaume, H ;
Nemoz, C ;
Fiedler, S ;
Bravin, A ;
Berruyer, G ;
Brochard, T ;
Renier, M ;
Machecourt, J ;
Thomlinson, W ;
Le Bas, JF .
EUROPEAN HEART JOURNAL, 2005, 26 (13) :1284-1291
[5]   On site evaluation of three flat panel detectors for digital radiography [J].
Borasi, G ;
Nitrosi, A ;
Ferrari, P ;
Tassoni, D .
MEDICAL PHYSICS, 2003, 30 (07) :1719-1731
[6]   Comparison between a position sensitive germanium detector and a taper optics CCD "FRELON" camera for diffraction enhanced imaging [J].
Bravin, A ;
Fiedler, S ;
Coan, P ;
Labiche, JC ;
Ponchut, C ;
Peterzol, A ;
Thomlinson, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 510 (1-2) :35-40
[7]   Phase-contrast X-ray imaging combining free space propagation and Bragg diffraction [J].
Coan, P ;
Pagot, E ;
Fiedler, S ;
Cloetens, P ;
Baruchel, J ;
Bravin, A .
JOURNAL OF SYNCHROTRON RADIATION, 2005, 12 :241-245
[8]  
CORDE S, 2002, THESIS U J FOURIER G
[9]  
Cunningham I. A., 2000, HDB MED IMAGING, V1, P79
[10]   A METHOD FOR MODULATION TRANSFER-FUNCTION DETERMINATION FROM EDGE PROFILES WITH CORRECTION FOR FINITE-ELEMENT DIFFERENTIATION [J].
CUNNINGHAM, IA ;
FENSTER, A .
MEDICAL PHYSICS, 1987, 14 (04) :533-537