Linear-wavenumber spectrometer for high-speed spectral-domain optical coherence tomography

被引:83
作者
Gelikonov, V. M. [1 ]
Gelikonov, G. V. [1 ]
Shilyagin, P. A. [1 ]
机构
[1] Russian Acad Sci, Inst Appl Phys, Nizhnii Novgorod 603950, Russia
关键词
SWEPT SOURCE; REFLECTOMETRY; LASER;
D O I
10.1134/S0030400X09030242
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An equidistant (in the wavenumber) spectrometer based on a diffraction grating, a compensation prism, and a CCD linear array is developed and implemented for spectral-domain optical coherence tomography. A criterion is introduced for estimating the level of residual nonequidistance. This criterion allows one to determine the threshold compensation level necessary for obtaining the spectrally limited spatial resolution. The method is tested in spectral-domain optical coherent tomography systems at wavelengths of 1270 and 830 nm.
引用
收藏
页码:459 / 465
页数:7
相关论文
共 17 条
[1]  
BERKOWITZ RS, 1965, MODERN RADAR ANAL EV
[2]   Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source [J].
Choma, MA ;
Hsu, K ;
Izatt, JA .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (04)
[3]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[4]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[5]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[6]   Optimization of Fizeau-based optical coherence tomography with a reference Michelson interferometer [J].
V. M. Gelikonov ;
G. V. Gelikonov ;
P. A. Shilyagin .
Bulletin of the Russian Academy of Sciences: Physics, 2008, 72 (1) :93-97
[7]  
GELIKONOV VM, 1995, JETP LETT+, V61, P158
[8]   Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+:forsterite laser [J].
Golubovic, B ;
Bouma, BE ;
Tearney, GJ ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (22) :1704-1706
[9]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[10]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894