Fitting accuracy of zirconia single crowns produced via digital and conventional impressions-a clinical comparative study

被引:61
|
作者
Roediger, Matthias [1 ]
Heinitz, Arthur [1 ]
Buergers, Ralf [1 ]
Rinke, Sven [1 ]
机构
[1] Georg August Univ, Dept Prosthodont, Univ Med Ctr Goettingen, Robert Koch Str 40, D-37075 Gottingen, Germany
关键词
Zirconia crown; Digital impression; Cad/Cam; Fitting accuracy; Replica technique; MARGINAL FIT; CERAMIC CROWNS; IN-VITRO; RESTORATIONS; TECHNOLOGY; PERCEPTION; SILICONE; WORKFLOW; SYSTEMS;
D O I
10.1007/s00784-016-1924-y
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study focused on the clinical investigation of the internal and marginal fit of CAD/CAM-fabricated zirconia single crowns produced via conventional and digital impression techniques. In a private practice, 20 molar teeth, one from each of 20 patients, were prepared with a circumferential 1.0-mm deep chamfer and an occlusal reduction of 1.5 mm. Conventional impression (CI) taking with a polyvinylsiloxane material (Aquasil Monophase + Aquasil XLV; Dentsply, Konstanz, Germany) and intraoral scanning (IS) (Cara TRIOS; Heraeus, Hanau, Germany) of each of the preparations was performed, and then two respective zirconia copings per tooth were produced (20 crowns per group). The marginal and internal fit of the restorations was evaluated employing a replica technique. For statistical analysis, a pairwise comparison (Wilcoxon rank test) was performed. Zirconia single crowns produced with the IS technique revealed a statistically significant better precision of internal fit only in specific areas (chamfer area/occlusal area). The evaluation of marginal fit showed no significant differences between the two groups. All restorations of both groups offered internal and marginal gaps within the postulated clinical tolerance ranges. CAD/CAM-fabricated zirconia single crowns produced with CI and IS techniques offer adequate marginal and internal precision. However, the IS technique provides lower internal gaps in some specific areas. The clinical precision of fit of restorations produced with a CI and an IS technique appeared to be equivalent. Therefore, the IS technique can be rated as a suitable alternative for the manufacturing of single crowns.
引用
收藏
页码:579 / 587
页数:9
相关论文
共 50 条
  • [41] Marginal and internal fit of five-unit zirconia-based fixed dental prostheses fabricated with digital scans and conventional impressions: A comparative in vitro study
    Bandiaky, Octave Nadile
    Clouet, Roselyne
    Le Bars, Pierre
    Soueidan, Assem
    Le Guehennec, Laurent
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (09): : 846 - 853
  • [42] Do digital impressions have a greater accuracy for full-arch implant-supported reconstructions compared to conventional impressions? An in vitro study
    Shaikh, Mohsin
    Lakha, Tabrez
    Kheur, Supriya
    Qamri, Batul
    Kheur, Mohit
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2022, 22 (04) : 398 - 404
  • [43] A 5-year retrospective study of survival of zirconia single crowns fitted in a private clinical setting
    Ortorp, Anders
    Kihl, Maria Lind
    Carlsson, Gunnar E.
    JOURNAL OF DENTISTRY, 2012, 40 (06) : 527 - 530
  • [45] Clinical Outcome of Fully Digital Workflow for Single-Implant-Supported Crowns: A Retrospective Clinical Study
    Gianfreda, Francesco
    Pesce, Paolo
    Marcano, Erich
    Pistilli, Valeria
    Bollero, Patrizio
    Canullo, Luigi
    DENTISTRY JOURNAL, 2022, 10 (08)
  • [46] Marginal and Internal Fit of Ceramic Restorations Fabricated Using Digital Scanning and Conventional Impressions: A Clinical Study
    Lee, Jeong-Hyeon
    Son, Keunbada
    Lee, Kyu-Bok
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (12) : 1 - 11
  • [47] A Comparative Study of the Accuracy of Dies Made from Digital Intraoral Scanning vs. Elastic Impressions: An In Vitro Study
    Serag, Mahmoud
    Al Nassar, Talal
    Avondoglio, Dane
    Weiner, Saul
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (01): : 88 - 93
  • [48] Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: An in vitro study
    Alkindi, Shaikha
    Hamdoon, Zaid
    Aziz, Ahmed M.
    JOURNAL OF DENTISTRY, 2024, 146
  • [49] Comparative accuracy of digital impressions using universal dual-purpose scan jigs for maxillary implant full arch impressions: An in vitro study
    Almalki, Abdulrahman
    Akl, Mohmmed
    Robaian, Ali
    Althubaitiy, Ramzi
    Alnasser, Abdullah
    Anadioti, Evanthia
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025,
  • [50] Seven-year prospective clinical study on zirconia-based single crowns and fixed dental prostheses
    Gianluca M. Tartaglia
    Ernesto Sidoti
    Chiarella Sforza
    Clinical Oral Investigations, 2015, 19 : 1137 - 1145