FABRICATION OF THIN CH AND CD FILMS AND PATTERNED FILMS USING A HEAT PRESS TECHNIQUE FOR THE NIF AND OMEGA MAGNETIC RECOIL NEUTRON SPECTROMETER

被引:2
作者
Paguio, R. R. [1 ]
Jasion, D. J. [1 ]
Saito, K. M. [1 ]
Schoff, M. E. [1 ]
Jimenez, R. M. [1 ]
Hund, J. F. [1 ]
Farrell, M. P. [1 ]
机构
[1] Gen Atom Co, San Diego, CA 92186 USA
关键词
MRS; polymer film; planar targets; RADIOGRAPHY;
D O I
10.13182/FST63-2-268
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Deuterated polyethylene films as thin as 50 mu m have been produced using a four-post heated press method. These films are then cut into the desired shape (foil) and are used for the magnetic recoil spectrometer (MRS). The MRS is a diagnostic tool for inertial confinement fusion (ICF) experiments at the National Ignition Facility (NIF) and at the OMEGA Laser Facility at the University of Rochester Laboratory for Laser Energetics. The films produced by this method are more uniform and have fewer defects than foils prepared by previous methods. Whereas traditional films had a thickness limitation of 100 mu m, this new heat pressing method allows the fabrication of 50-mu m films, which is the desired thickness for MRS foils. The foils produced and characterized by General Atomics have decreased the neutron measurement uncertainty of the MRS instrument by a factor of 2 compared to the previous foils. This work has also been extended to fabricate thin polymer films and films with sinusoidal patterns from other polymeric materials for ICF experiments. This paper will discuss the heat pressing technique used in the fabrication of these films for the NIF and OMEGA MRS as well as other patterned and flat polymer films. The morphology of these foils and the advantages that they provide will also be discussed.
引用
收藏
页码:268 / 273
页数:6
相关论文
共 10 条
  • [1] Measuring the absolute deuterium-tritium neutron yield using the magnetic recoil spectrometer at OMEGA and the NIF
    Casey, D. T.
    Frenje, J. A.
    Johnson, M. Gatu
    Seguin, F. H.
    Li, C. K.
    Petrasso, R. D.
    Glebov, V. Yu.
    Katz, J.
    Knauer, J. P.
    Meyerhofer, D. D.
    Sangster, T. C.
    Bionta, R. M.
    Bleuel, D. L.
    Doeppner, T.
    Glenzer, S.
    Hartouni, E.
    Hatchett, S. P.
    Le Pape, S.
    Ma, T.
    MacKinnon, A.
    Mckernan, M. A.
    Moran, M.
    Moses, E.
    Park, H. -S.
    Ralph, J.
    Remington, B. A.
    Smalyuk, V.
    Yeamans, C. B.
    Kline, J.
    Kyrala, G.
    Chandler, G. A.
    Leeper, R. J.
    Ruiz, C. L.
    Cooper, G. W.
    Nelson, A. J.
    Fletcher, K.
    Kilkenny, J.
    Farrell, M.
    Jasion, D.
    Paguio, R.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10)
  • [2] Casey D. T., 2012, THESIS MIT
  • [3] FLETCHER K., 2010, COMMUNICATION
  • [4] Probing high areal-density cryogenic deuterium-tritium implosions using downscattered neutron spectra measured by the magnetic recoil spectrometer
    Frenje, J. A.
    Casey, D. T.
    Li, C. K.
    Seguin, F. H.
    Petrasso, R. D.
    Glebov, V. Yu.
    Radha, P. B.
    Sangster, T. C.
    Meyerhofer, D. D.
    Hatchett, S. P.
    Haan, S. W.
    Cerjan, C. J.
    Landen, O. L.
    Fletcher, K. A.
    Leeper, R. J.
    [J]. PHYSICS OF PLASMAS, 2010, 17 (05)
  • [5] First measurements of the absolute neutron spectrum using the magnetic recoil spectrometer at OMEGA (invited)
    Frenje, J. A.
    Casey, D. T.
    Li, C. K.
    Rygg, J. R.
    Seguin, F. H.
    Petrasso, R. D.
    Yu Glebov, V.
    Meyerhofer, D. D.
    Sangster, T. C.
    Hatchett, S.
    Haan, S.
    Cerjan, C.
    Landen, O.
    Moran, M.
    Song, P.
    Wilson, D. C.
    Leeper, R. J.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10)
  • [6] FRENJE J. A., 2010, COMMUNICATION
  • [7] A neutron spectrometer for precise measurements of DT neutrons from 10 to 18 MeV at OMEGA and the National Ignition Facility
    Frenje, JA
    Green, KM
    Hicks, DG
    Li, CK
    Séguin, FH
    Petrasso, RD
    Sangster, TC
    Phillips, TW
    Glebov, VY
    Meyerhofer, DD
    Roberts, S
    Soures, JM
    Stoeckl, C
    Fletcher, K
    Padalino, S
    Leeper, RJ
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01) : 854 - 858
  • [8] Quantitative radiography: Film model calibration and dopant/impurity measurement in ICF ablators
    Huang, H.
    Stephens, R. B.
    Nikroo, A.
    Eddinger, S. A.
    Chen, K. C.
    Xu, H. W.
    Moreno, K. A.
    Youngblood, K. P.
    Skelton, M.
    [J]. FUSION SCIENCE AND TECHNOLOGY, 2007, 51 (04) : 530 - 538
  • [9] Nondestructive quantitative dopant profiling technique by contact radiography
    Huang, H.
    Stephens, R. B.
    Eddinger, S. A.
    Gunther, J.
    Nikroo, A.
    Chen, K. C.
    Xu, H. W.
    [J]. FUSION SCIENCE AND TECHNOLOGY, 2006, 49 (04) : 650 - 656
  • [10] Neutron spectrometry-An essential tool for diagnosing implosions at the National Ignition Facility (invited)
    Johnson, M. Gatu
    Frenje, J. A.
    Casey, D. T.
    Li, C. K.
    Seguin, F. H.
    Petrasso, R.
    Ashabranner, R.
    Bionta, R. M.
    Bleuel, D. L.
    Bond, E. J.
    Caggiano, J. A.
    Carpenter, A.
    Cerjan, C. J.
    Clancy, T. J.
    Doeppner, T.
    Eckart, M. J.
    Edwards, M. J.
    Friedrich, S.
    Glenzer, S. H.
    Haan, S. W.
    Hartouni, E. P.
    Hatarik, R.
    Hatchett, S. P.
    Jones, O. S.
    Kyrala, G.
    Le Pape, S.
    Lerche, R. A.
    Landen, O. L.
    Ma, T.
    MacKinnon, A. J.
    McKernan, M. A.
    Moran, M. J.
    Moses, E.
    Munro, D. H.
    McNaney, J.
    Park, H. S.
    Ralph, J.
    Remington, B.
    Rygg, J. R.
    Sepke, S. M.
    Smalyuk, V.
    Spears, B.
    Springer, P. T.
    Yeamans, C. B.
    Farrell, M.
    Jasion, D.
    Kilkenny, J. D.
    Nikroo, A.
    Paguio, R.
    Knauer, J. P.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10)