Analysis of trickle bed and packed bubble column bioreactors for combined carbon oxidation and nitrification

被引:9
作者
Iliuta, I [1 ]
Bildea, SC
Iliuta, MC
Larachi, F
机构
[1] Univ Laval, Dept Chem Engn, Quebec City, PQ G1K 7P4, Canada
[2] Univ Laval, CERPIC, Quebec City, PQ G1K 7P4, Canada
[3] Univ Politehn Bucharest, Dept Chem Engn, Bucharest 78126, Romania
[4] Univ Politehn Bucharest, Dept Appl Phys Chem, Bucharest 78126, Romania
关键词
carbon oxidation; nitrification; trickle bed reactors; packed bed columns; modelling;
D O I
10.1590/S0104-66322002000100006
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Biological removal of nitrogen and carbon by combined nitrification-oxidation in gas-liquid trickle-bed reactors (TBRs) and packed bubble columns (PBCs) was analyzed theoretically using a transient two-dimensional model. The model describes TBR and PBC performances at steady state as well as their transient response to a pulse or step increase in inlet methanol and NH4+-nitrogen concentrations. The hydrodynamic parameters were determined from residence time distribution measurements, using an imperfect pulse method for time-domain analysis of nonideal pulse tracer response. A transient diffusion model of the tracer in the porous particle coupled with the piston-dispersion-exchange model was used to interpret the residence time distribution curves obtained. Gas-liquid mass transfer parameters were determined by a stationary method based on the least-squares fit of the calculated concentration profiles in gas phase to the experimental values. Analysis of steady-state performances showed that under like operating conditions, the TBR outperforms the PBC in terms of conversions. A pulse change in the inlet methanol or NH4+-nitrogen concentration causes a negligible transient change in the outlet methanol concentration and a negligible or high transient change in the outlet NH4+-nitrogen concentration. A step change in the inlet methanol concentration causes the negligible transient change in the methanol outlet concentration and a relatively important transient change in the NH4+-nitrogen outlet concentration. A step increase in the NH4+-nitrogen inlet concentration induces a drastic transient change in the NH4+-nitrogen outlet concentration but a negligible transient change in the methanol outlet concentration.
引用
收藏
页码:69 / 87
页数:19
相关论文
共 44 条
[1]  
ALLONSO C, 1997, BIOTECHNOL BIOENG, V54, P583
[2]  
ATIQULLAH M, 1990, CHEM ENG J, V44, pB15
[3]   Effect of sinusoidal variation of feed concentration and temperature on the performance of a packed-bed biological reactor - A theoretical study [J].
Beg, SA ;
Hassan, MM ;
Chaudhry, MAS .
CHEMICAL ENGINEERING & TECHNOLOGY, 1996, 19 (01) :43-49
[4]   Effect of fasting condition on multi-substrate carbon oxidation and nitrification system in an upflow packed-bed biofilm reactor [J].
Beg, SA ;
Hassan, MM ;
Chaudhry, MAS .
CHEMICAL ENGINEERING & TECHNOLOGY, 1997, 20 (03) :162-170
[5]  
BEG SA, 1995, INT J ENVIRON STUD, V49, P31
[6]   ELECTROCHEMICAL STUDY OF LIQUID-SOLID MASS-TRANSFER IN PACKED-BEDS WITH UPWARD COCURRENT GAS-LIQUID FLOW [J].
DELAUNAY, G ;
STORCK, A ;
LAURENT, A ;
CHARPENTIER, JC .
INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1980, 19 (04) :514-521
[7]  
DESHUSSES MA, 1995, ENVIRON SCI TECHNOL, V29, P1059, DOI 10.1021/es00004a028
[8]   VERIFICATION STUDIES OF A SIMPLIFIED MODEL FOR THE REMOVAL OF DICHLOROMETHANE FROM WASTE GASES USING A BIOLOGICAL TRICKLING FILTER .1. [J].
DIKS, RMM ;
OTTENGRAF, SPP .
BIOPROCESS ENGINEERING, 1991, 6 (03) :93-99
[9]  
Finlayson BA., 1972, Method of Weighted Residuals and Variational Principles
[10]   MATHEMATICAL MODELIZATION OF A PACKED-BED REACTOR PERFORMANCE WITH IMMOBILIZED YEAST FOR ETHANOL FERMENTATION [J].
GODIA, F ;
CASAS, C ;
SOLA, C .
BIOTECHNOLOGY AND BIOENGINEERING, 1987, 30 (07) :836-843