摘要
Introduction. Pulse wave velocity (PWV) is an emerging predictor in the assessment of cardiovascular risk in diseased and healthy populations. We suggest a novel method for the accurate measurement of PWV. Method. PWV is calculated from pulse transit time using two separate pulse recordings over a known distance. 8F sheaths were placed in the right femoral arteries and routine coronary angiographies were performed with 5F diagnostic catheters. Ascending aorta pressures were measured with right diagnostic catheter tip in the ascending aorta and synchronous femoral artery pressures were measured with the sheath in the femoral artery. The distance between the two pressure sites was calculated as follows: total length of the right diagnostic catheter-length of the catheter outside the sheath-Sheath length. Results. We evaluated the PWV measured using the catheter method in 24 subjects. PWV correlated positively and independently with age (p = 0.004), coronary artery disease (p = 0.04), ascending aorta systolic pressure (p = 0.006), femoral artery systolic pressure (p = 0.008), ascending aorta pulse pressure (p = 0.003) and femoral artery pulse pressure (p = 0.04). In coronary artery disease patients, the mean PWV value was significantly higher than in patients with normal coronary arteries (12.61 +/- 6.31 m/s vs 7.58 +/- 2.26 m/s p = 0.04). Conclusion. We describe a novel and accurate but invasive method for measurement of PWV. Our results may serve as a reference for non-invasive assessment of aorta-femoral artery PWV.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 50 条
[31]   Measurement of regional pulse-wave velocity using spatial compound imaging of the common carotid artery in vivo [J].
Nagaoka, Ryo ;
Masuno, Genta ;
Kobayashi, Kazuto ;
Yoshizawa, Shin ;
Umemura, Shin-ichiro ;
Saijo, Yoshifumi .
ULTRASONICS, 2015, 55 :92-103
[32]   Feasibility of a method for measurement of retinal pulse-propagated wave velocity in humans [J].
Tang, Zhengxin ;
Felder, Anthony E. ;
Shahidi, Mahnaz .
MICROVASCULAR RESEARCH, 2025, 159
[33]   Repeatability of non-invasive measurement of intracerebral pulse wave velocity using transcranial Doppler [J].
Gladdish, S ;
Manawadu, D ;
Banya, W ;
Cameron, J ;
Bulpitt, CJ ;
Rajkumar, C .
CLINICAL SCIENCE, 2005, 108 (05) :433-439
[34]   Carotid-femoral pulse wave velocity assessment using novel cuff-based techniques: comparison with tonometric measurement [J].
Butlin, Mark ;
Qasem, Ahmad ;
Battista, Francesca ;
Bozec, Erwan ;
McEniery, Carmel M. ;
Millet-Amaury, Eugenie ;
Pucci, Giacomo ;
Wilkinson, Ian B. ;
Schillaci, Giuseppe ;
Boutouyrie, Pierre ;
Avolio, Alberto P. .
JOURNAL OF HYPERTENSION, 2013, 31 (11) :2237-2243
[35]   Accuracy and Repeatability of Fourier Velocity Encoded M-Mode and Two-Dimensional Cine Phase Contrast for Pulse Wave Velocity Measurement in the Descending Aorta [J].
Taviani, Valentina ;
Patterson, Andrew J. ;
Graves, Martin J. ;
Hardy, Christopher J. ;
Worters, Pauline ;
Sutcliffe, Michael P. F. ;
Gillard, Jonathan H. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (05) :1185-1194
[36]   Determination of radial artery compliance can increase the diagnostic power of pulse wave velocity measurement [J].
Ferreira, AS ;
Santos, MAR ;
Barbosa, J ;
Cordovil, I ;
Souza, MN .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) :37-50
[37]   Validation of a new piezo-electronic device for non-invasive measurement of arterial pulse wave velocity according to the artery society guidelines [J].
Margarita S. Morales ;
Paula E. Cuffaro ;
Jessica Barochiner ;
Marcelo A. Rada ;
Jose Alfie ;
Lucas Aparicio ;
Marcos Marin ;
Carlos R. Galarza ;
Gabriel D. Waisman .
Artery Research, 2015, 10 :32-37
[38]   Particle Image Velocimetry to Evaluate Pulse Wave Velocity in Aorta Phantom with the lnD-U Method [J].
Moravia, Anais ;
Simoens, Serge ;
El Hajem, Mahmoud ;
Bou-Said, Benyebka ;
Menut, Marine ;
Kulisa, Pascale ;
Lermusiaux, Patrick ;
Della-Schiava, Nellie .
CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2023, 14 (01) :141-151
[39]   Continuous measurement of carotid-femoral pulse wave velocity (PWVcf.) during general anaesthesia using Doppler: a preliminary study [J].
Harle, Theophile ;
Joachim, Jona ;
Boutouyrie, Pierre ;
Mateo, Joaquim ;
Perdereau, Jade ;
Mebazaa, Alexandre ;
Cartailler, Jerome ;
Vallee, Fabrice .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2025, 39 (03) :495-503
[40]   A Simple Method of Measuring Thoracic Aortic Pulse Wave Velocity in Children: Methods and Normal Values [J].
Jo, Colleen O. ;
Lande, Marc B. ;
Meagher, Cecilia C. ;
Wang, Hongyue ;
Vermilion, Roger P. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (07) :735-740