A front-end electronic system for large arrays of bolometers

被引:44
作者
Arnaboldi, C. [1 ,2 ]
Carniti, P. [1 ,2 ]
Cassina, L. [1 ,2 ]
Gotti, C. [1 ,2 ]
Liu, X. [3 ]
Maino, M. [1 ,2 ]
Pessina, G. [1 ,2 ]
Rosenfeld, C. [3 ]
Zhu, B. X. [4 ]
机构
[1] Ist Nazl Fis Nucl, Sez Milano Bicocca, Piazza Sci 3, I-20126 Milan, Italy
[2] Univ Milano Bicocca, Dipartimento Fis G Occhialini, Piazza Sci 3, I-20126 Milan, Italy
[3] Univ South Carolina, Dept Phys & Astron, Columbia, SC 29208 USA
[4] Univ Calif Los Angeles, Dept Phys & Astron, 475 Portola Plaza, Los Angeles, CA 90095 USA
来源
JOURNAL OF INSTRUMENTATION | 2018年 / 13卷
基金
欧洲研究理事会;
关键词
Analogue electronic circuits; Front-end electronics for detector readout; Modular electronics; Detector control systems (detector and experiment monitoring and slow-control systems; architecture; hardware; algorithms databases); DOUBLE-BETA-DECAY; LARGE-MASS BOLOMETERS; LOW-FREQUENCY; THERMAL DETECTORS; RARE DECAYS; CUORE; NOISE; SPECTROSCOPY; STABILITY; DESIGN;
D O I
10.1088/1748-0221/13/02/P02026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
CUORE is an array of thermal calorimeters composed of 988 crystals held at about 10 mK, whose absorbed energy is read out with semiconductor thermistors. The composition of the crystal is TeO2, and the aim is the study of the double beta decay of Te-130 on very long and stable runs. CUPID-0 is an array of 26 (ZnSe)-Se-82 crystals with double thermistor readout to study the double beta decay of Se-82. In the present paper, we present an overview of the entire front-end electronic readout chain, from the preamplifier to the anti-aliasing filter. This overview includes motivations, design strategies, circuit implementation and performance results of the electronic system, including other auxiliary yet important elements like power supplies and the slow control communication system. The stringent requirements of stability on the very long experimental runs that are foreseen during CUORE and CUPID-0 operation, are achieved thanks to novel solutions of the front-end preamplifier and of the detector bias circuit setup.
引用
收藏
页数:23
相关论文
共 39 条
  • [1] CUORE-0 detector: design, construction and operation
    Alduino, C.
    Alfonso, K.
    Artusa, D. R.
    Avignone, F. T., III
    Azzolini, O.
    Balata, M.
    Banks, T. I.
    Bari, G.
    Beeman, J. W.
    Bellini, F.
    Bersani, A.
    Biare, D.
    Biassoni, M.
    Bragazzi, F.
    Brofferio, C.
    Buccheri, A.
    Bucci, C.
    Bulfon, C.
    Caminata, A.
    Canonica, L.
    Cao, X. G.
    Capelli, S.
    Capodiferro, M.
    Cappelli, L.
    Carbone, L.
    Cardani, L.
    Cariello, M.
    Carniti, P.
    Casali, N.
    Cassina, L.
    Cereseto, R.
    Ceruti, G.
    Chiarini, A.
    Chiesa, D.
    Chott, N.
    Clemenza, M.
    Conventi, D.
    Copello, S.
    Cosmelli, C.
    Cremonesi, O.
    Creswick, R. J.
    Cushman, J. S.
    D'Addabbo, A.
    Dafinei, I.
    Davis, C. J.
    Dell'Oro, S.
    Deninno, M. M.
    Di Domizio, S.
    Di Vacri, M. L.
    DiPaolo, L.
    [J]. JOURNAL OF INSTRUMENTATION, 2016, 11
  • [2] Methods for response stabilization in bolometers for rare decays
    Alessandrello, A
    Brofferio, C
    Bucci, C
    Cremonesi, O
    Giuliani, A
    Margesin, B
    Nucciotti, A
    Pavan, M
    Pessina, G
    Previtali, E
    Zen, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 412 (2-3) : 454 - 464
  • [3] A low DC drift read-out system for a large mass bolometric detector
    Alessandrello, A
    Brofferio, C
    Bucci, C
    Camin, DV
    Cremonesi, O
    Giuliani, A
    Nucciotti, A
    Pavan, M
    Pessina, G
    Previtali, E
    Sablich, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 416 - 423
  • [4] The low radioactivity link of the CUORE experiment
    Andreotti, E.
    Arnaboldi, C.
    Barucci, M.
    Brofferio, C.
    Cosmelli, C.
    Calligaris, L.
    Capelli, S.
    Clemenza, M.
    Maiano, C.
    Pellicciari, M.
    Pessina, G.
    Pirro, S.
    [J]. JOURNAL OF INSTRUMENTATION, 2009, 4
  • [5] JFET transistors for low-noise applications at low frequency
    Arnaboldi, C
    Boella, G
    Panzeri, E
    Pessina, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (06) : 2975 - 2982
  • [6] Very low noise AC/DC power supply systems for large detector arrays
    Arnaboldi, C.
    Bau, A.
    Carniti, P.
    Cassina, L.
    Giachero, A.
    Gotti, C.
    Maino, M.
    Passerini, A.
    Pessina, G.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (12)
  • [7] CUORE: a cryogenic underground observatory for rare events
    Arnaboldi, C
    Avignone, FT
    Beeman, J
    Barucci, M
    Balata, M
    Brofferio, C
    Bucci, C
    Cebrian, S
    Creswick, RJ
    Capelli, S
    Carbone, L
    Cremonesi, O
    de Ward, A
    Fiorini, E
    Farach, HA
    Frossati, G
    Giuliani, A
    Giugni, D
    Gorla, P
    Haller, EE
    Irastorza, IG
    McDonald, RJ
    Morales, A
    Norman, EB
    Negri, P
    Nucciotti, A
    Pedretti, M
    Pobes, C
    Palmieri, V
    Pavan, M
    Pessina, G
    Pirro, S
    Previtali, E
    Rosenfeld, C
    Smith, AR
    Sisti, M
    Ventura, G
    Vanzini, M
    Zanotti, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (03) : 775 - 798
  • [8] Programmable calibrating pulse generator with multi-outputs and very high stability
    Arnaboldi, C
    Pessina, G
    Previtali, E
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (04) : 979 - 986
  • [9] The Preamplifier for CUORE, an Array of Large Mass Bolometers
    Arnaboldi, C.
    Liu, X.
    Pessina, G.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 389 - +
  • [10] Low-frequency noise characterization of very large value resistors
    Arnaboldi, C
    Bucci, C
    Cremonesi, O
    Fascilla, A
    Nucciotti, A
    Pavan, M
    Pessina, G
    Pirro, S
    Previtali, E
    Sisti, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) : 1808 - 1813