Synthetic double inversion recovery imaging in brain MRI: quantitative evaluation and feasibility of synthetic MRI and a comparison with conventional double inversion recovery and fluid-attenuated inversion recovery sequences

被引:3
作者
Zorigt, Odgerel [1 ]
Nakajima, Takahito [1 ,2 ]
Kumasaka, Yuka [1 ,3 ]
Jingu, Akiko [1 ,3 ]
Tsushima, Yoshito [1 ]
机构
[1] Gunma Univ, Dept Diagnost Radiol & Nucl Med, Grad Sch Med, 3-39-22 Showa, Maebashi, Gumma 3719511, Japan
[2] Univ Tsukuba, Dept Diagnost & Intervent Radiol, 1-1-1 Tennoudai, Tsukuba, Ibaraki 3058575, Japan
[3] Fujioka Gen Hosp, Dept Radiol, 813-1 Nakakurisu, Fujioka, Gunma 3750015, Japan
关键词
Magnetic resonance imaging; Synthetic magnetic resonance imaging; Double inversion recovery; Inversion recovery; MULTIPLE-SCLEROSIS; MATTER; DISEASE;
D O I
10.1186/s12880-022-00877-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background and purpose Synthetic MR imaging (SyMRI) allows the reconstruction of various contrast images, including double inversion recovery (DIR), from a single scan. This study aimed to investigate the advantages of SyMRI by comparing synthetic DIR images with synthetic T2-weighted fluid-attenuated inversion recovery (T2W-FLAIR) and conventional DIR images. Materials and methods We retrospectively reviewed the imaging data of 100 consecutive patients who underwent brain MRI between December 2018 and March 2019. Synthetic DIR, T2W-FLAIR, T1-weighted, and phase-sensitive inversion recovery (PSIR) images were generated from SyMRI data. For synthetic DIR, the two inversion times required to suppress white matter and cerebrospinal fluid (CSF) were manually determined by two radiologists. Quantitative analysis was performed by manually tracing the region of interest (ROI) at the sites of the lesion, white matter, and CSF. Synthetic DIR, synthetic T2W-FLAIR, and conventional DIR images were compared on the basis of using the gray matter-to-white matter, lesion-to-white matter, and lesion-to-CSF contrast-to-noise ratios. Results The two radiologists showed no differences in setting inversion time (TI) values, and their evaluations showed excellent interobserver agreement. The mean signal intensities obtained with synthetic DIR were significantly higher than those obtained with synthetic T2W-FLAIR and conventional DIR. Conclusion Synthetic DIR images showed a higher contrast than synthetic T2WFLAIR and conventional DIR images.
引用
收藏
页数:7
相关论文
共 16 条
[11]   Double inversion recovery imaging improves the evaluation of gray matter volume losses in patients with Alzheimer's disease and mild cognitive impairment [J].
Jahng, Geon-Ho ;
Lee, Dong Kyun ;
Lee, Jong-Min ;
Rhee, Hak Young ;
Ryu, Chang-Woo .
BRAIN IMAGING AND BEHAVIOR, 2016, 10 (04) :1015-1028
[12]  
REDPATH TW, 1994, MAGN RESON MATER PHY, V2, P451, DOI 10.1007/BF01705296
[13]   Imaging the neocortex in epilepsy with double inversion recovery imaging [J].
Rugg-Gunn, Fergus J. ;
Boulby, Philip A. ;
Symms, Mark R. ;
Barker, Gareth J. ;
Duncan, John S. .
NEUROIMAGE, 2006, 31 (01) :39-50
[14]   Synthetic MRI for Clinical Neuroimaging: Results of the Magnetic Resonance Image Compilation (MAGiC) Prospective, Multicenter, Multireader Trial [J].
Tanenbaum, L. N. ;
Tsiouris, A. J. ;
Johnson, A. N. ;
Naidich, T. P. ;
DeLano, M. C. ;
Melhem, E. R. ;
Quarterman, P. ;
Parameswaran, S. X. ;
Shankaranarayanan, A. ;
Goyen, M. ;
Field, A. S. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (06) :1103-1110
[15]   3D double inversion recovery MR imaging: Clinical applications and usefulness in a wide spectrum of central nervous system diseases [J].
Umino, Maki ;
Maeda, Masayuki ;
Ii, Yuichiro ;
Tomimoto, Hidekazu ;
Sakuma, Hajime .
JOURNAL OF NEURORADIOLOGY, 2019, 46 (02) :107-116
[16]  
Wattjes MP, 2007, AM J NEURORADIOL, V28, P54