Validity of Digital Templating in Total Hip Arthroplasty: Impact of Stem Design and Planner's Experience

被引:16
作者
Jung, S. [1 ]
Neuerburg, C. [1 ]
Kappe, T. [1 ]
Wernerus, D. [1 ]
Reichel, H. [1 ]
Bieger, R. [1 ]
机构
[1] Univ Ulm Klinikum, Orthopad Klin, D-89081 Ulm, Germany
来源
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE | 2012年 / 150卷 / 04期
关键词
hip replacement; total hip arthroplasty; digital templating; preoperative planning; short stem; ILIOPSOAS IMPINGEMENT; REPLACEMENT; ACCURACY; CALIBRATION; RADIOGRAPHS; ANALOG; TRIAL;
D O I
10.1055/s-0031-1298386
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Preoperative planning in total hip arthroplasty decreases the risk of implant oversizing and facilitates intraoperative orientation. The size of the acetabular and femural components can be estimated. The aim of the present study was to determine the validitiy of digital templating. Furthermore, we compared the accuracy of three planners with different clinical experience and the effect of two different femoral component designs on planning accuracy. Methods: On 60 a.p. pelvis radiographs, 60 unilateral, non-cemented total hip arthroplasties using the planning tool "AGFA-Orthopaedic-Tools Version V2.10 (R)" (Fa. Agfa Health Care, Mertsel, Belgium) were repeatedly planned by three orthopaedic surgeons (planner A fifth year, planner B third year, planner C second year of training). All 60 patients received pressfit acetabular components, a straight stem was implanted in 28 (CLS-Spotorno (TM), Fa. Zimmer) and a short stem (Fit-more, Fa. Zimmer) in 32 patients. The planned sizes of the components and the offset-variations were compared to the implanted sizes. Results: The percental accuracy and ICC planning for the straight stem were 42.9%/0.906 for planner A, 39.3%/0.833 for planner B, and 28.6%/0.836 for planner C. Planning the short stem, the percental accuracy and ICC were 34.4%/0,886 for planner A, 21.9%/0.708 for planner B, and 12.5%/0.681 for planner C. The accuracy and ICC of templating the acetabular components were 35%/0.796 for planner A, 30%/0.725 for planner B, and 26.8%/0.511 for planner C. Planning the sizes of both femoral components showed significant differences between planner A and C and planner B and C in Wilcoxon's signed-rank test. Conclusion: A lower level of experience showed no effect on the planning results of the acetabular components, but there were considerable and significant differences on planning the femoral components. Furthermore, the design of the femoral component had an impact on planning accuracy.
引用
收藏
页码:404 / 408
页数:5
相关论文
共 20 条
[1]   Evaluation of the Accuracy and Use of X-Ray Markers in Digital Templating for Total Hip Arthroplasty [J].
Bayne, Christopher O. ;
Krosin, Michael ;
Barber, Thomas C. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (03) :407-413
[2]  
Berstock JR, 2010, ANN ROY COLL SURG, V92, P73, DOI [10.1308/003588410X12518836440289, 10.1308/rcsann.2010.92.1.73]
[3]   DETERMINATION OF ACCURACY OF PREOPERATIVE TEMPLATING OF NONCEMENTED FEMORAL PROSTHESES [J].
CARTER, LW ;
STOVALL, DO ;
YOUNG, TR .
JOURNAL OF ARTHROPLASTY, 1995, 10 (04) :507-513
[4]   Iliopsoas impingement on the acetabular component:: Radiologic and computed tomography findings of a rare prosthesis complication in eight cases [J].
Cyteval, C ;
Sarrabère, P ;
Cottin, A ;
Assi, C ;
Morcos, L ;
Maury, P ;
Taourel, P .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (02) :183-188
[5]   Preoperative planning for primary total hip arthroplasty [J].
Della Valle, AG ;
Padgett, DE ;
Salvati, EA .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2005, 13 (07) :455-462
[6]   The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty [J].
Della Valle, AG ;
Slullitel, G ;
Piccaluga, F ;
Salvati, EA .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :51-58
[7]   Assessment of mobility after multi-level surgery for cerebral palsy [J].
Graham, H. K. ;
Harvey, A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (08) :993-994
[8]   A comparison of four systems for calibration when templating for total hip replacement with digital radiography [J].
Franken, M. ;
Grimm, B. ;
Heyligers, I. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (01) :136-141
[9]   The Accuracy of Digital Templating in Uncemented Total Hip Arthroplasty [J].
Gamble, Patrick ;
de Beer, Justin ;
Petruccelli, Danielle ;
Winemaker, Mitchell .
JOURNAL OF ARTHROPLASTY, 2010, 25 (04) :529-532
[10]   Preoperative Planning and Reconstruction in Primary Total Hip Arthroplasty with and without Modular Necks [J].
Heep, H. ;
Wegner, A. ;
Xu, J. ;
Kauther, M. ;
Loeer, F. A. .
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2010, 148 (02) :180-184