Refraction in Children: A Comparison of Two Methods of Accommodation Control

被引:19
|
作者
Hopkins, Shelley [1 ]
Sampson, Geoff P. [1 ]
Hendicott, Peter [1 ]
Lacherez, Philippe [1 ]
Wood, Joanne M. [1 ]
机构
[1] Queensland Univ Technol, Sch Optometry & Vis Sci, Inst Hlth & Biomed Innovat, Brisbane, Qld 4001, Australia
关键词
refractive error; children; methodology; retinoscopy; autorefraction; cycloplegia; fogging technique; HAND-HELD AUTOREFRACTOR; PRESCHOOL-CHILDREN; CYCLOPLEGIC REFRACTIONS; ERROR; RETINOSCOPY; PREVALENCE; MYOPIA;
D O I
10.1097/OPX.0b013e318277182c
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The prevalence of refractive errors in children has been extensively researched. Comparisons between studies can, however, be compromised because of differences between accommodation control methods and techniques used for measuring refractive error. The aim of this study was to compare spherical refractive error results obtained at baseline and using two different accommodation control methods-extended optical fogging and cycloplegia-for two measurement techniques-autorefraction and retinoscopy. Methods. Participants included 25 school children aged 6 to 13 years (mean age, 9.52 +/- 2.06 years). The refractive error of one eye was measured at baseline and again under two different accommodation control conditions: extended optical fogging (+ 2.00DS for 20 minutes) and cycloplegia (1% cyclopentolate). Autorefraction and retinoscopy were both used to measure the most plus spherical power for each condition. Results. A significant interaction was demonstrated between measurement technique and accommodation control method (p = 0.036), with significant differences in spherical power evident between accommodation control methods for each of the measurement techniques (p < 0.005). For retinoscopy, refractive errors were significantly more positive for cycloplegia compared with optical fogging, which were in turn significantly more positive than baseline; whereas for autorefraction, there were significant differences between cycloplegia and extended optical fogging and between cycloplegia and baseline only. Conclusions. Determination of refractive error under cycloplegia elicits more plus than using extended optical fogging as a method to relax accommodation. These findings support the use of cycloplegic refraction compared with extended optical fogging as a means of controlling accommodation for population-based refractive error studies in children. (Optom Vis Sci 2012; 89: 1734-1739)
引用
收藏
页码:1734 / 1739
页数:6
相关论文
共 50 条
  • [21] Do all children need a cycloplegic refraction? A comparison of Mohindra's versus cycloplegic refraction
    Kauser, Farnaz
    Gupta, Yogesh
    Amitava, Abadan K.
    Saxena, Juhi
    Raza, S. Aisha
    Masood, Anam
    Alam, Md Shahid
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (11) : 2458 - 2461
  • [22] Comparison of Manifest Refraction and Cycloplegic Refraction Using Retinoscopy or an Autorefractor in Children
    Park, Aram
    Chung, Seung Ah
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (08): : 1274 - 1281
  • [23] Refraction under general anesthesia in children, using cycloplegic refraction only as a reference
    Ocak, Osman Bulut
    Inal, Asli
    Tuelue Ayguen, Beril
    Kirmaci Kabakci, Asli
    Kemer Atik, Burcu
    Yurttaser Ocak, Serap
    Goekyigit, Birsen
    STRABISMUS, 2020, 28 (02) : 73 - 78
  • [24] Comparison of Two Therapies on Asthma Control in Children
    Al-Turki, Anas
    Salvator, Ann
    Bai, Shasha
    Sheikh, Shahid, I
    PEDIATRIC ALLERGY IMMUNOLOGY AND PULMONOLOGY, 2020, 33 (03) : 127 - 135
  • [25] A comparison of cycloplegic effect of cyclopentolate 0.5% versus 1.0% eye drops with five different refraction measurement modalities in young adults
    Kaiser, Klemens Paul
    Lwowski, Christoph
    Nazir, Faisal
    Kohnen, Thomas
    Wenner, Yaroslava
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, : 1135 - 1146
  • [26] Accuracy of Two Autorefractors - Pediatric Autorefractor plusoptiX and Retinomax - in Cycloplegic Children in Comparison to Retinoscopy
    Schmidt-Bacher, A. E.
    Kahlert, C.
    Kolling, G.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2010, 227 (10) : 792 - 797
  • [27] A Comparison of Optical Biometers Used in Children for Myopia Control
    Mattern, Ann-Isabel
    Neller, Kai
    Devenijn, Machteld
    Schwahn, Hartmut
    Langenbucher, Achim
    Seitz, Berthold
    Kaymak, Hakan
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2023, 240 (11) : 1306 - 1313
  • [28] COMPARISON OF TWO METHODS OF FIXATION OF SUPRACONDYLAR FRACTURES OF THE HUMERUS IN CHILDREN
    Natalin, Henrique Melo
    da Silva, Jessica Colamarino Sessa
    Volpon, Jose Batista
    ACTA ORTOPEDICA BRASILEIRA, 2021, 29 (05): : 263 - 267
  • [29] How to measure time preferences in children: a comparison of two methods
    Angerer, Silvia
    Lergetporer, Philipp
    Glaetzle-Ruetzler, Daniela
    Sutter, Matthias
    JOURNAL OF THE ECONOMIC SCIENCE ASSOCIATION-JESA, 2015, 1 (02): : 158 - 169
  • [30] How to measure time preferences in children: a comparison of two methods
    Silvia Angerer
    Philipp Lergetporer
    Daniela Glätzle-Rützler
    Matthias Sutter
    Journal of the Economic Science Association, 2015, 1 (2) : 158 - 169