High Performance Liquid Chromatographic Determination of Residual Monomer Released from Heat-Cured Acrylic Resin. An In Vivo Study

被引:25
作者
Singh, Raghuwar D. [1 ]
Gautam, Rupali [1 ]
Siddhartha, Ramashanker [1 ]
Singh, Balendra P. [1 ]
Chand, Pooran [1 ]
Sharma, Vinod P. [2 ]
Jurel, Sunit K. [1 ]
机构
[1] King Georges Med Univ UP, Dept Prosthodont, Fac Dent Sci, Lucknow, Uttar Pradesh, India
[2] Indian Inst Toxicol & Res, CSIR, Lucknow, Uttar Pradesh, India
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2013年 / 22卷 / 05期
关键词
Complete denture; heat-cured acrylic resin; high performance liquid chromatography; residual monomer methyl methacrlylate; saliva; DENTURE BASE MATERIALS; METHYL-METHACRYLATE; CYTOTOXICITY;
D O I
10.1111/jopr.12004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose Heat-polymerized acrylic resins are used in dentistry for complete denture fabrication. Despite the polymerization method, conversion of monomer into polymer is often incomplete with free or unreacted residual monomer remaining in the polymerized resin. The aim of this study was to determine the amount of residual monomeric methyl methacrylate (MMA) leaching in the saliva of patients wearing complete dentures in their postinsertion period. Materials and Methods Thirty edentulous participants as first-time complete denture wearers (age 60 to 65 years) were selected. All the prostheses were fabricated using a similar standard technique with a heat-cured acrylic resin denture base material. Saliva samples were collected at time intervals of 1 hour, 1 day, and 3 days postdenture insertion. Participants were asked to discharge saliva every 30 seconds into a pre-weighed screw-capped container for a 5-minute period. MMA levels were measured using high performance liquid chromatography. Data were analyzed by ANOVA and Tukey-HSD. Results The maximum concentration of monomer released into saliva peaked 1 day after insertion of the complete dentures. The mean (SD) MMA content was 0.04 +/- 0.01 (g/ml) 1 hour after insertion, and 0.3 +/- 0.09 (g/ml), and 0.05 +/- 0.01 (g/ml) on the first and third days postinsertion, respectively. Conclusions Although the released monomeric MMA was not at toxic levels, it could potentially sensitize complete denture patients or elicit an allergic reaction. The risk of the residual material as a primary irritant for a sensitizing reaction could be minimized by immersion of the denture in water for 24 hours before insertion.
引用
收藏
页码:358 / 361
页数:4
相关论文
共 20 条
[1]  
Anusavice KJ., 1996, Phillips' science of dental materials, V10th, P237
[2]   THE LEVEL OF RESIDUAL MONOMER IN ACRYLIC DENTURE BASE MATERIALS - WITH PARTICULAR REFERENCE TO A MODIFIED METHOD OF ANALYSIS [J].
AUSTIN, AT ;
BASKER, RM .
BRITISH DENTAL JOURNAL, 1980, 149 (10) :281-286
[3]   THE RELEASE OF RESIDUAL MONOMERIC METHYL-METHACRYLATE FROM ACRYLIC APPLIANCES IN THE HUMAN MOUTH - AN ASSAY FOR MONOMER IN SALIVA [J].
BAKER, S ;
BROOKS, SC ;
WALKER, DM .
JOURNAL OF DENTAL RESEARCH, 1988, 67 (10) :1295-1299
[4]   Biodegradation of acrylic based resins: A review [J].
Bettencourt, Ana F. ;
Neves, Cristina B. ;
de Almeida, Marise S. ;
Pinheiro, Lidia M. ;
Oliveira, Sofia Arantes e ;
Lopes, Luis P. ;
Castro, Matilde F. .
DENTAL MATERIALS, 2010, 26 (05) :E171-E180
[5]   STUDIES ON CHRONIC ORAL TOXICITY OF MONOMERIC ETHYL ACRYLATE + METHYL METHACRYLATE [J].
BORZELLECA, JF ;
CRAWFORD, EM ;
SMITH, RB ;
LARSON, PS ;
HUF, EG ;
HENNIGAR, GR .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1964, 6 (01) :29-&
[6]   LINEAR DIMENSIONAL VARIABILITY OF 3 DENTURE BASE RESINS AFTER PROCESSING AND IN WATER STORAGE [J].
DIXON, DL ;
BREEDING, LC ;
EKSTRAND, KG .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (01) :196-200
[7]  
Fisher AA., 1956, J PROSTHET DENT, V6, P593, DOI DOI 10.1016/0022-3913(56)90003-8
[8]   THE CYTO-TOXIC EFFECT OF DENTURE BASE POLYMERS [J].
HENSTENPETTERSEN, A ;
WICTORIN, L .
ACTA ODONTOLOGICA SCANDINAVICA, 1981, 39 (02) :101-106
[9]  
Hyeok-JaeLee, 2003, [The Journal of Korean Academy of Prosthodontics, 대한치과보철학회지], V41, P360
[10]   Cytotoxicity of denture base acrylic resins: A literature review [J].
Jorge, JH ;
Giampaolo, ET ;
Machado, AL ;
Vergani, CE .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (02) :190-193