Accuracy of craniocervical measurements on CT for identifying partial or complete craniocervical ligament injuries in pediatric patients

被引:1
|
作者
Beckmann, Nicholas M. [1 ]
Cheekatla, Suresh K. [1 ]
Chinapuvvula, Naga R. [1 ]
Zhang, Xu [2 ]
West, O. Clark [1 ]
机构
[1] Univ Texas Hlth Sci Ctr Houston, McGovern Med Sch, Dept Diagnost & Intervent Imaging, Mem Hermann, 6431 Fannin St,2-130B, Houston, TX 77030 USA
[2] Univ Texas Hlth Sci Ctr Houston, McGovern Med Sch, Dept Internal Med, 6410 Fannin St,UTPB 1100-08, Houston, TX 77030 USA
关键词
Pediatric; Cervical; Spine; Trauma; Musculoskeletal; Craniocervical; Imaging; CERVICAL-SPINE INJURIES; COMPUTED-TOMOGRAPHY; ATLANTOOCCIPITAL JUNCTION; DIAGNOSIS; PATTERNS; AGE;
D O I
10.1007/s00256-020-03555-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To assess the accuracy of craniocervical measurements for identifying craniocervical injuries and the frequency of subjective findings of craniocervical injuries on CT in pediatric patients. Methods Case-controlled retrospective review of patients <= 16 years old with craniocervical junction injuries. Receiver operator curves were created for common craniocervical measurements on CT comparing patients with complete and partial craniocervical injuries to uninjured cohort. Frequency of subjective CT findings of craniocervical injury was assessed in the injured cohort. Results For complete disruption injuries (CD) (n = 27), C1-C2 distance (AUC = 0.90, 95%CI = 0.83-0.97), atlanto-occipital distance (AUC = 0.95-0.98, 95%CI = 0.90-1.00), and basion-dens distance (AUC = 0.90, 95%CI = 0.82-0.98) had excellent accuracy diagnosing injury. Powers ratio (AUC = 0.85, 95%CI = 0.76-0.94) had good, basion-posterior axial line (AUC = 0.74, 95%CI = 0.61-0.86) fair, and atlanto-dental distance (AUC = 0.69, 95%CI = 0.57-0.82) poor accuracy. For partial disruption injuries (PD) (n = 21), basion-dens distance (AUC = 0.75, 95%CI = 0.62-0.88) had fair accuracy diagnosing injury. Powers ratio (AUC = 0.63, 95%CI = 0.47-0.79), C1-C2 distance (AUC = 0.60, 95%CI = 0.45-0.75), atlanto-dental distance (AUC = 0.55, 95%CI = 0.39 = 0.71), atlanto-occipital distance (AUC = 0.63-0.65, 95%CI = 0.47-0.81), and basion-posterior axial line (AUC = 0.60, 95%CI = 0.44-0.76) all had poor accuracy. Eighty-one percent (n = 22) of CD and 38% (n = 8) of PD patients had non-concentric atlanto-occipital joints. One hundred percent of CD patients had >= 1 soft tissue finding and eighty-one percent (n = 22) had >= 2 findings. Seventy-three percent (n = 16) of PD patients had >= 1 soft tissue finding. Eighty-six percent (n = 18) of PD patients had non-concentric atlanto-occipital joints and/or soft tissue findings. Conclusion Craniocervical measurements have poor accuracy for identifying craniocervical injuries in pediatric patients with incomplete craniocervical ligament disruption. Subjective findings of craniocervical injury are frequently present on CT in pediatric patients and can help increase sensitivity for identifying injury.
引用
收藏
页码:159 / 169
页数:11
相关论文
共 29 条
  • [21] Effect of voxel size and partial volume effect on accuracy of tooth volumetric measurements with cone beam CT: Author response
    Peters, O.
    Maret, D.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (05)
  • [22] Identifying myocardial injuries in "normal-appearing" myocardium in pediatric patients with clinically suspected myocarditis using mapping techniques
    Wang, Haipeng
    Zhao, Bin
    Yang, Huan
    Qian, Tianyi
    Han, Bo
    Jia, Haipeng
    An, Jing
    Zhao, Junyu
    Wang, Ximing
    Wang, Cuiyan
    PEERJ, 2020, 8
  • [23] Accuracy of Medical Student Measurements of CT Right-to-Left Ventricular Diameter in Patients with Acute Pulmonary Embolism
    Durant, Edward J.
    Fetterolf, Sarah M.
    Engelhart, Darcy C.
    Farshidpour, Leyla S.
    Shan, Judy
    Hung, Yun-Yi
    Chang, Joshua C.
    Roudsari, Bahman S.
    Vinson, David R.
    JOURNAL OF MEDICAL EDUCATION AND CURRICULAR DEVELOPMENT, 2023, 10
  • [24] Automated patient positioning in CT using a 3D camera for body contour detection: accuracy in pediatric patients
    Booij, Ronald
    van Straten, Marcel
    Wimmer, Andreas
    Budde, Ricardo P. J.
    EUROPEAN RADIOLOGY, 2021, 31 (01) : 131 - 138
  • [25] Emergency whole-body CT scans in pediatric patients with trauma: patterns of injuries, yield of dual-phase scanning, and influence of second read on detection of injuries
    Didion, Pauline
    Crombe, Amandine
    Dabadie, Alexia
    Hassid, Sophie
    Seux, Mylene
    Gorincour, Guillaume
    Banaste, Nathan
    EUROPEAN RADIOLOGY, 2022, 32 (12) : 8473 - 8484
  • [26] Realistic extension of partial-body pediatric CT for whole-body organ dose estimation in radiotherapy patients
    Rafet, Sergio Morato
    Lee, Choonik
    Griffin, Keith T.
    Saha, Monjoy
    Lee, Choonsik
    Mille, Matthew M.
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [27] Diagnostic accuracy of dual-energy CT for detecting bone marrow edema in patients with acute knee injuries: a systematic review and meta-analysis
    Mitchell P. Wilson
    Kevin Lui
    Dorian Nobbee
    Mohammad H. Murad
    Prayash Katlariwala
    Gavin Low
    Skeletal Radiology, 2021, 50 : 871 - 879
  • [28] Diagnostic accuracy of dual-energy CT for detecting bone marrow edema in patients with acute knee injuries: a systematic review and meta-analysis
    Wilson, Mitchell P.
    Lui, Kevin
    Nobbee, Dorian
    Murad, Mohammad H.
    Katlariwala, Prayash
    Low, Gavin
    SKELETAL RADIOLOGY, 2021, 50 (05) : 871 - 879
  • [29] CT-guided sacroiliac percutaneous screw placement in unstable posterior pelvic ring injuries: Accuracy of screw position, injury reduction and complications in 71 patients with 136 screws
    Pieske, Oliver
    Landersdorfer, Christoph
    Trumm, Christoph
    Greiner, Axel
    Wallmichrath, Jens
    Gottschalk, Oliver
    Rubenbauer, Bianka
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (02): : 333 - 339