Optimization of the thickness of a ZnS/6LiF scintillator for a high-resolution detector installed on a focusing small-angle neutron scattering spectrometer (SANS-U)

被引:8
|
作者
Iwase, Hiroki [1 ]
Katagiri, Masaki [2 ]
Shibayama, Mitsuhiro [1 ]
机构
[1] Univ Tokyo, Inst Solid State Phys, Neutron Sci Lab, Tokai, Ibaraki 3191106, Japan
[2] Japan Atom Energy Agcy, J PARC Ctr, Tokai, Ibaraki 3191195, Japan
来源
关键词
INSTRUMENT; UPGRADE;
D O I
10.1107/S0021889812008928
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study involves the upgrade of a high-resolution position-sensitive detector (HR-PSD) installed on the small-angle neutron scattering spectrometer (SANS-U) at the Japan Atomic Energy Agency. By using both neutron lenses and the HR-PSD, the accessible low-Q limit can be extended to the order of 10(-4) angstrom(-1) [Q is the magnitude of the scattering vector defined by Q = (4 pi/lambda) sin theta, where lambda and 2 theta are the wavelength and the scattering angle, respectively]. The HR-PSD consists of a cross-wired position-sensitive photomultiplier tube (PSPMT) and a commercial ZnS/(LiF)-Li-6 scintillator. To improve the experimental efficiency of focusing small-angle neutron scattering (FSANS) experiments, a high-performance ZnS/(LiF)-Li-6 scintillator developed at the Japan Atomic Energy Agency has been utilized. For the PSPMT and data-acquisition system installed on SANS-U, the thickness of the ZnS/(LiF)-Li-6 scintillator was optimized by measuring the thickness dependence of the pulse-height spectra. Under the experimental conditions of SANS-U, the optimum thickness of the ZnS/(LiF)-Li-6 scintillator (ZnS:(LiF)-Li-6 = 2: 1) was determined to be 0.433 mm by measuring the total counts and peak positions of the pulse-height spectra. Installation of the optimized ZnS/(LiF)-Li-6 scintillator improved detection efficiency by 1.39 times over that of a commercial scintillator at the same level of background counts and Q resolution in FSANS experiments.
引用
收藏
页码:507 / 512
页数:6
相关论文
共 27 条
  • [21] In Situ Measurement of Ionomer Water Content and Liquid Water Saturation in Fuel Cell Catalyst Layers by High-Resolution Small-Angle Neutron Scattering
    Lee, Jongmin
    Escribano, Sylvie
    Micoud, Fabrice
    Gebel, Gerard
    Lyonnard, Sandrine
    Porcar, Lionel
    Martinez, Nicolas
    Morin, Arnaud
    ACS APPLIED ENERGY MATERIALS, 2020, 3 (09): : 8393 - 8401
  • [22] SPINODAL DECOMPOSITION OF THE POLYMER BLEND DEUTEREOUS POLYSTYRENE (D-PS) AND POLYVINYLMETHYLETHER (PVME) STUDIED WITH HIGH-RESOLUTION NEUTRON SMALL-ANGLE SCATTERING
    SCHWAHN, D
    YEEMADEIRA, H
    COLLOID AND POLYMER SCIENCE, 1987, 265 (10) : 867 - 875
  • [23] Structural characterization of manganese-substituted nanocrystalline zinc oxide using small-angle neutron scattering and high-resolution transmission electron microscopy
    Roy, B.
    Karmakar, B.
    Bahadur, J.
    Mazumder, S.
    Sen, D.
    Pal, M.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2009, 42 : 1085 - 1091
  • [24] A STUDY OF OXYGEN PRECIPITATION IN SILICON USING HIGH-RESOLUTION TRANSMISSION ELECTRON-MICROSCOPY, SMALL-ANGLE NEUTRON-SCATTERING AND INFRARED-ABSORPTION
    BERGHOLZ, W
    BINNS, MJ
    BOOKER, GR
    HUTCHISON, JC
    KINDER, SH
    MESSOLORAS, S
    NEWMAN, RC
    STEWART, RJ
    WILKES, JG
    PHILOSOPHICAL MAGAZINE B-PHYSICS OF CONDENSED MATTER STATISTICAL MECHANICS ELECTRONIC OPTICAL AND MAGNETIC PROPERTIES, 1989, 59 (05): : 499 - 522
  • [25] Installation of a high-resolution position-sensitive scintillation detector in the small and wide angle neutron scattering instrument (TAIKAN), MLF, J-PARC
    Iwase, Hiroki
    Takata, Shin-ichi
    Morikawa, Toshiaki
    Katagiri, Masaki
    Birumachi, Atsushi
    Suzuki, Jun-ichi
    PHYSICA B-CONDENSED MATTER, 2018, 551 : 501 - 505
  • [27] NEW HIGH-RESOLUTION SMALL-ANGLE X-RAY SCATTERING APPARATUS USING A FINE-FOCUS ROTATING ANODE, POINT-FOCUSING COLLIMATION AND A POSITION-SENSITIVE PROPORTIONAL COUNTER.
    Yoda, Osamu
    Journal of Applied Crystallography, 1984, 17 (pt 5): : 337 - 343