Shear response of concrete-filled FRP composite cylindrical shells

被引:13
|
作者
Burgueño, R
Bhide, KM
机构
[1] Michigan State Univ, Dept Civil & Environm Engn, E Lansing, MI 48824 USA
[2] Engn Serv & Consultants Inc, Youngstown, OH 44503 USA
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 2006年 / 132卷 / 06期
关键词
D O I
10.1061/(ASCE)0733-9445(2006)132:6(949)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an analytical procedure for predicting the shear load-deformation response of concrete filled fiber-reinforced polymer (FRP) composite cylindrical shells with full- and noncomposite behavior. The approach is based on a sectional layered analysis with an iterative algorithm to achieve equilibrium and compatibility conditions of the FRP/concrete system, including the cracked behavior of the FRP-confined concrete, until first-ply failure of the FRP composite. The model follows first order mechanics for the shear behavior of structural members in combination with a smeared shear modulus for cracked concrete and inclusion of extension/shear coupling effects of anisotropic FRP laminates. Comparisons of the analytical response with available experimental data from large- and small-scale tests were found to be in reasonable agreement and corroborated the significant influence of the concrete core and the composite interaction details on the shear load-deformation response. Parametric studies on the influence of concrete properties, axial loads, and FRP laminate design are discussed.
引用
收藏
页码:949 / 960
页数:12
相关论文
共 50 条
  • [1] New concrete-filled hollow FRP composite column
    Univ of Central Florida, Orlando, United States
    Compos Part B:Eng, 3-4 (263-268):
  • [2] A new concrete-filled hollow FRP composite column
    Mirmiran, A
    Shahawy, M
    COMPOSITES PART B-ENGINEERING, 1996, 27 (3-4) : 263 - 268
  • [3] Seismic behavior of composite shear walls incorporating concrete-filled steel and FRP tubes as boundary elements
    Ren, Fengming
    Chen, Jinwen
    Chen, Guangming
    Guo, Yaxin
    Jiang, Tao
    ENGINEERING STRUCTURES, 2018, 168 : 405 - 419
  • [4] Concrete-filled FRP tubes tested
    不详
    CIVIL ENGINEERING, 2000, 70 (03): : 28 - 28
  • [5] Splicing of precast concrete-filled FRP tubes
    Zhu, Zhenyu
    Ahmad, Iftekhar
    Mirmiran, Amir
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2006, 10 (04) : 345 - 356
  • [6] Comparative analysis of bond performance for concrete-filled FRP piles and concrete-filled steel piles
    Wang, Zhengzhen
    Gong, Weiming
    Dai, Guoliang
    Liu, Lingfeng
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2019, 49 (05): : 933 - 939
  • [7] Behaviour of FRP-strengthened concrete-filled steel tubular composite columns
    College of Civil Engineering, Fuzhou University, Fujian, Fuzhou 350108, China
    不详
    Harbin Gongye Daxue Xuebao, 1600, SUPPL. 2 (18-21):
  • [8] Bending and Shear Behaviour of Waste Rubber Concrete-Filled FRP Tubes with External Flanges
    Ferdous, Wahid
    Manalo, Allan
    AlAjarmeh, Omar S.
    Zhuge, Yan
    Mohammed, Ali A.
    Bai, Yu
    Aravinthan, Thiru
    Schubel, Peter
    POLYMERS, 2021, 13 (15)
  • [9] Experimental investigation of a simple shear connection to concrete-filled FRP tube (CFFT) columns
    Hain, Alexandra
    Zaghi, Arash E.
    ENGINEERING STRUCTURES, 2021, 247
  • [10] Deformation capacity of concrete-filled steel plate composite shear walls
    Hu, Hong-Song
    Nie, Jian-Guo
    Eatherton, Matthew R.