CO2 stripping from ionic liquid at elevated pressures in gas-liquid membrane contactor

被引:31
作者
Bazhenov, Stepan [1 ]
Malakhov, Alexander [1 ]
Bakhtin, Danila [1 ]
Khotimskiy, Valery [1 ]
Bondarenko, Galina [1 ]
Volkov, Vladimir [1 ]
Ramdin, Mahinder [2 ]
Vlugt, Thijs J. H. [2 ]
Volkov, Alexey [1 ]
机构
[1] AV Topchiev Inst Petrochem Synth RAS, Leninsky Prospect 29, Moscow 119991, Russia
[2] Delft Univ Technol, Proc & Energy Dept, Leeghwaterstr 39, NL-2628 CB Delft, Netherlands
关键词
Membrane contactor; Room-temperature ionic liquid; PTMSP; Carbon dioxide; Stripping; CARBON-DIOXIDE CAPTURE; OF-THE-ART; ABSORPTION PROCESS; REGENERATION; SOLUBILITY; MONOETHANOLAMINE; POLYMER; PERMEABILITY; SELECTIVITY; PERMEATION;
D O I
10.1016/j.ijggc.2018.03.001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, the gas-liquid membrane contactor was considered for regeneration of the room-temperature ionic liquids (RTIL) that can be used as physical solvents for carbon dioxide capture process at elevated pressures. Poly [1-(trimethylsilyl)-1-propyne] (PTMSP) was selected as a membrane material due to its high mass transport characteristics and good mechanical properties. Nine different RTILs, such as [Emim][DCA], [Emim][BF4], [Emim][DEP], [Bmim][BF4], [Bmim][Tf2N], [Hmim][TCB], [P66614][DCA], [P66614][Br] and [P66614] [Phos], were used to evaluate the solvent-membrane compatibility. The long-term sorption tests (40+ days) revealed that the solvent-membrane interaction is mainly determined by the liquid surface tension regardless of viscosity and molecular size of RTILs. For instance, [Emim][BF4] and [Emim][DCA], having the surface tension of 60.3 and 54.0 mN/m, demonstrated a very low affinity to the bulk material of PTMSP (sorption as low as 0.02 g/g; no swelling); while for the next ionic liquid [Bmim][BF4] with surface tension of 44.4 mN/m, the sorption and swelling of PTMSP was 0.79 g/g and 21%, respectively. The long-term RTIL permeation test (Delta p=40 bar, T=50 degrees C, t > 400 h) confirmed that there is no hydrodynamic flow through PTMSP for [Emim] [DCA] and [Emim][BF4]. The concept of CO2 stripping from RTIL with the membrane contactor by the pressure (Delta p=10 bar) and temperature (Delta T=20 degrees C) swing was proved by using dense PTMSP membrane and [Emim] [BF4]. The overall mass transfer coefficient value was equal to (1.6-3.8) x10(-3) cm/s with respect to liquid flow rate. By using the resistance-in-series model, it was shown that the membrane resistance contribution to the gas transfer was estimated to be approximately 8%.
引用
收藏
页码:293 / 302
页数:10
相关论文
共 58 条
  • [11] Pressure swing membrane absorption process for shifted syngas separation: Modeling vs. experiments for pure ionic liquid
    Chau, John
    Obuskovic, Gordana
    Jie, Xingming
    Sirkar, Kamalesh K.
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2014, 453 : 61 - 70
  • [12] CUSSLER EL, 1994, NATO ADV SCI INST SE, V272, P375
  • [13] Modelling of a tubular membrane contactor for pre-combustion CO2 capture using ionic liquids: Influence of the membrane configuration, absorbent properties and operation parameters
    Dai, Zhongde
    Usman, Muhammad
    Hillestad, Magne
    Deng, Liyuan
    [J]. GREEN ENERGY & ENVIRONMENT, 2016, 1 (03) : 266 - 275
  • [14] Membrane absorption using ionic liquid for pre-combustion CO2 capture at elevated pressure and temperature
    Dai, Zhongde
    Deng, Liyuan
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2016, 54 : 59 - 69
  • [15] Precombustion CO2 Capture in Polymeric Hollow Fiber Membrane Contactors Using Ionic Liquids: Porous Membrane versus Nonporous Composite Membrane
    Dai, Zhongde
    Ansaloni, Luca
    Deng, Liyuan
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (20) : 5983 - 5992
  • [16] Combination of ionic liquids with membrane technology: A new approach for CO2 separation
    Dai, Zhongde
    Noble, Richard D.
    Gin, Douglas L.
    Zhang, Xiangping
    Deng, Liyuan
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2016, 497 : 1 - 20
  • [17] Robust high-permeance PTMSP composite membranes for CO2 membrane gas desorption at elevated temperatures and pressures
    Dibrov, G. A.
    Volkov, V. V.
    Vasilevsky, V. P.
    Shutova, A. A.
    Bazhenov, S. D.
    Khotimsky, V. S.
    de Runstraat, A. van
    Goetheer, E. L. V.
    Volkov, A. V.
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2014, 470 : 439 - 450
  • [18] Membrane-solvent selection for CO2 removal using membrane gas-liquid contactors
    Dindore, VY
    Brilman, DWF
    Geuzebroek, FH
    Versteeg, GF
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 40 (02) : 133 - 145
  • [19] Simulation of the Onset of Flow through a PTMSP-Based Polymer Membrane during Nanofiltration of Water-Methanol Mixture
    Filippov, A. N.
    Ivanov, V. I.
    Yushkin, A. A.
    Volkov, V. V.
    Bogdanova, Yu. G.
    Dolzhikova, V. D.
    [J]. PETROLEUM CHEMISTRY, 2015, 55 (05) : 347 - 362
  • [20] Hollow fiber membrane contactors
    Gabelman, A
    Hwang, ST
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1999, 159 (1-2) : 61 - 106