Direct Relationship between Angiographic Characteristics of Carotid Atherosclerotic Plaque and Filling Defect in the Cerebral Protection Filters : Based on the Conventional Angiography

被引:0
|
作者
Choi, Jae-Hyung [1 ]
Park, Hyun-Seok [1 ]
Kim, Dae-Hyun [2 ]
Cha, Jae-Kwan [2 ]
Huh, Jae-Taeck [1 ]
Kang, Myongjin [3 ]
机构
[1] Dong A Univ, Dept Neurosurg, Busan Ulsan Reg Cardiocerebrovasc Ctr, Med Sci Res Ctr,Coll Med, Pusan 602715, South Korea
[2] Dong A Univ, Dept Neurol, Busan Ulsan Reg Cardiocerebrovasc Ctr, Med Sci Res Ctr,Coll Med, Pusan 602715, South Korea
[3] Dong A Univ, Dept Diagnost Radiol, Busan Ulsan Reg Cardiocerebrovasc Ctr, Med Sci Res Ctr,Coll Med, Pusan 602715, South Korea
关键词
Carotid artery; Angiography; Plaque; HIGH-RISK PATIENTS; LESION CHARACTERISTICS; SYMPTOMATIC PATIENTS; ARTERY; STENOSIS; ENDARTERECTOMY; ANGIOPLASTY; COMPLICATIONS; ULCERATION; MORPHOLOGY;
D O I
10.3340/jkns.2013.54.2.93
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective : Neurologic complications during carotid artery stenting (CAS) are usually associated with distal embolic event. These embolic incident during CAS are highly associated with the carotid plaque instability. The current study was undertaken to identify the angiographic characteristics of carotid plaque vulnerability, which was represented as filling defect in the cerebral protection filters during CAS. Methods : A total of 107 patients underwent CAS with use of a distal protection filter. Angiographic carotid plaque surface morphology was classified as smooth, irregular, and ulcerated. To determine predictable factors of filling defect in the protection filters, 11 variables were retrospectively analyzed which might influence filling defect in the protection filters during CAS. Results : Filling defects during CAS were presented in the 33 cerebral protection filters. In multivariate analysis, angiographic ulceration [odds ratio (OR), 6.60; 95% confidence interval (CI) : 2.24, 19.4; p=0.001], higher stenosis degree (OR, 1.06; 95% CI : 1.00, 1.12; p=0.039), and coexistent thrombus (OR, 7.58; 95% CI : 1.69, 34.05; p=0.08) were highly associated with filling defect in the cerebral protection devices during CAS. Among several variables, angiographic surface ulceration was the only significant factor associated with flow stagnation during CAS (OR, 4.11; 95% CI : 1.33, 12.72; p=0.014). Conclusion : Plaque surface morphology on carotid angiography can be a highly sensitive marker of plaque instability during CAS. The independent risk factors for filling defect in the filter devices during CAS were plaque ulceration, stenosis degree, and coexistent thrombus.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 3 条
  • [1] Relationship between carotid plaque characteristics and new ischemic lesions after stenting detected by computed tomography angiography
    Qu, Hongying
    Zhang, Xiaokun
    Zhang, Miao
    Gao, Yongan
    Lu, Jie
    ACTA RADIOLOGICA, 2020, 61 (01) : 47 - 55
  • [2] Relationship between epicardial adipose tissue volume measured using coronary computed tomography angiography and atherosclerotic plaque characteristics in patients with severe coronary artery stenosis
    Dong, Dan-Dan
    Wang, Kai
    Wang, Dan
    Zhang, Tong
    Tu, Ying-Feng
    Shen, Bao-Zhong
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2013, 41 (05) : 1520 - 1531
  • [3] Relationship Between Endothelial Wall Shear Stress and High-Risk Atherosclerotic Plaque Characteristics for Identification of Coronary Lesions That Cause Ischemia: A Direct Comparison With Fractional Flow Reserve
    Han, Donghee
    Starikov, Anna
    Hartaigh, Briain O.
    Gransar, Heidi
    Kolli, Kranthi K.
    Lee, Ji Hyun
    Rizvi, Asim
    Baskaran, Lohendran
    Schulman-Marcus, Joshua
    Lin, Fay Y.
    Min, James K.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (12):