Neutral analyte focusing by micelle collapse in micellar electrokinetic chromatography

被引:49
|
作者
Quirino, Joselito P. [1 ]
机构
[1] Univ Tasmania, Sch Chem, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
关键词
On-line sample preconcentration; Normal migration micellar electrokinetic chromatography; Analyte focusing by micelle collapse; Neutral analyzes; Isotachophoresis;
D O I
10.1016/j.chroma.2008.10.074
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The operating parameters that affect the performance of analyte focusing by micelle collapse (AFMC) to neutral analyzes (i.e dialkyl phthalates) in normal migration micellar electrokinetic chromatography (NM-MEKC) are examined. NM-MEKC is characterized by an electroosmotic flow greater than the electrophoretic velocity of the micellar pseudostationary phase, and was performed using sodium dodecyl sulfate (SDS) with neutral to high pH electrolytes in fused silica capillaries. AFMC is a recently introduced on-line sample preconcentration technique in capillary electrophoresis that can provide hundreds fold improvement in detection sensitivity. The mechanism of AFMC is based on the analyte transport, release, and accumulation by the moving surfactant micelles [e.g., SDS at concentrations closer to the critical micelle concentration (CMC)] in the sample that dilutes below its CIVIC into a liquid phase zone. The sample is prepared in a matrix that contains SDS micelles and high mobility anions, where the conductivity of the sample matrix is higher compared to that of the separation solution. The sample injection length, sample and separation solution conductivity ratio, and surfactant micelle concentration in the sample were found to affect the AFMC performance, as well as the effective separation length in NM-MEKC. The use of a different electrolyte salt in the sample and separation solution also affected AFMC NM-MEKC results. In particular, sodium chloride in the sample matrix can induce a micelle-mediated neutral analyte isotachophoretic concentration that is detrimental to the technique. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:171 / 177
页数:7
相关论文
共 30 条
  • [1] STEROID FOCUSING BY MICELLE COLLAPSE IN MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    Khir, Northaqifah Hasna Mohamed
    Jaafar, Jafariah
    Bakar, Mohd Bakri
    JURNAL TEKNOLOGI, 2012, 57
  • [2] Heart-cut two-dimensional separation method via hyphenation of micellar electrokinetic capillary chromatography and capillary zone electrophoresis using analyte focusing by micelle collapse
    Zhang, Xiaowei
    Zhang, Zhaoxiang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (19): : 1641 - 1646
  • [3] Analyte focusing by micelle collapse in CZE: Nanopreparation of neutrals
    Quirino, Joselito P.
    ELECTROPHORESIS, 2009, 30 (05) : 875 - 882
  • [4] Neutral analyte focusing by micelle collapse in partial-filling MEKC with UV and ESI-MS detection
    Quirino, Joselito P.
    Haddad, Paul R.
    ELECTROPHORESIS, 2009, 30 (10) : 1670 - 1674
  • [5] Micelle to trapping solution stacking in micellar electrokinetic chromatography
    Liu, Lihong
    Deng, Xinxian
    Chen, Xingguo
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (01) : 175 - 178
  • [6] Analyte focusing by micelle collapse for liquid extraction surface analysis coupled with capillary electrophoresis of neutral analytes on a solid surface
    Jeong, Sunkyung
    Shakerian, Farid
    Chung, Doo Soo
    ELECTROPHORESIS, 2019, 40 (18-19) : 2463 - 2468
  • [7] Micelle to solvent stacking of organic cations in micellar electrokinetic chromatography with sodium dodecyl sulfate
    Quirino, Joselito P.
    Aranas, Agnes T.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (41) : 7377 - 7383
  • [8] Chiral Micellar Electrokinetic Chromatography
    Salido-Fortuna, Sandra
    Castro-Puyana, Maria
    Luisa Marina, Maria
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1626
  • [9] Capillary Separation: Micellar Electrokinetic Chromatography
    Terabe, Shigeru
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2009, 2 : 99 - 120
  • [10] Sweeping of neutral analytes in partial-filling micellar electrokinetic chromatography with electrospray ionization mass spectrometry
    Quirino, Joselito P.
    ELECTROPHORESIS, 2011, 32 (6-7) : 665 - 668