Influence of high volumes of silica fume on the rheological behavior of oil well cement pastes

被引:25
作者
Burroughs, Jedadiah F. [1 ,2 ]
Weiss, Jason [3 ]
Haddock, John E. [2 ]
机构
[1] US Army, Geotech & Struct Lab, Engineer Res & Dev Ctr, 3909 Halls Ferry Rd, Vicksburg, MS 39180 USA
[2] Purdue Univ, Lyles Sch Civil Engn, 550 Stadium Mall Dr, W Lafayette, IN 47907 USA
[3] Oregon State Univ, Sch Civil & Construct Engn, Corvallis, OR 97331 USA
关键词
Rheology; Surface area; Silica fume; Cement paste; Oil well cement; SUPERPLASTICIZERS; STRENGTH;
D O I
10.1016/j.conbuildmat.2019.01.027
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Specialized classes of concrete, such as ultra-high performance concrete, use volumes of silica fume in concrete that are higher than those in conventional concrete, resulting in increased water demand and mixing difficulty. This study considered the effects of eight different silica fumes in three dosages (10%, 20%, 30%) with three w/b (0.20, 0.30, 0.45) on rheological behavior as characterized by the Herschel-Bulkley model. Results indicated that the specific source of silica fume used, in addition to dosage and w/b, had a significant effect on the rheological behavior. As such, all silica fumes cannot be treated as equivalent or be directly substituted one for another without modification of the mixture proportion. The rheology of cement pastes is significantly affected by the physical properties of silica fume more so than any chemical effects. Published by Elsevier Ltd.
引用
收藏
页码:401 / 407
页数:7
相关论文
共 26 条
  • [1] ACI Concrete Terminology, 2016, CT16 ACI, P1
  • [2] [Anonymous], 2015, Standard Specification for Silica Fume Used in Cementitious Mixtures, DOI [10.1520/C1240-15, DOI 10.1520/C1240-15]
  • [3] [Anonymous], 2016, Standard Test Methods for Sampling and Testing Fly Ash or Natural Pozzolans for Use in Portland-Cement Concrete, DOI DOI 10.1520/C0311_C0311M-17
  • [4] [Anonymous], 2013, Ultra-High Performance Concrete: A State-Of-The-Art Report for the Bridge Community
  • [5] ASTM D4254-16, 2016, STAND TEST METH MIN, DOI [10.1520/D4254-16, DOI 10.1520/D4254-16]
  • [6] ASTM International, 2014, STAND TEST METH SPEC, DOI [10.1520/D0854-14, DOI 10.1520/D0854-14]
  • [7] ASTM International, 2017, STAND GUID MEAS RHEO, DOI [10.1520/C1749-17A, DOI 10.1520/C1749-17A]
  • [8] Bernhardt C., 1952, Betongen Idag, V17, P29
  • [9] Bischof Carl R., 2009, ACI MANUAL CONCRETE
  • [10] The effect of the silica content of silica fume on its ability to control alkali-silica reaction
    Boddy, AM
    Hooton, RD
    Thomas, MDA
    [J]. CEMENT AND CONCRETE RESEARCH, 2003, 33 (08) : 1263 - 1268