Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients

被引:38
作者
Bendjelid, K. [1 ]
Marx, G. [2 ]
Kiefer, N. [3 ]
Simon, T. P. [2 ]
Geisen, M. [4 ]
Hoeft, A. [3 ]
Siegenthaler, N. [1 ]
Hofer, C. K. [4 ]
机构
[1] Univ Hosp Geneva, Intens Care Serv, CH-1211 Geneva 14, Switzerland
[2] Rhein Westfal TH Aachen, Univ Hosp Aachen, Dept Anaesthesiol, D-52062 Aachen, Germany
[3] Univ Bonn, Dept Anesthesiol & Intens Care Med, Bonn, Germany
[4] Triemli City Hosp Zurich, Inst Anesthesiol & Intens Care Med, Zurich, Switzerland
关键词
continuous cardiac output; pulse wave analysis; transpulmonary thermodilution; PULMONARY-ARTERY CATHETERS; END-DIASTOLIC VOLUME; TRANSPULMONARY THERMODILUTION; RELIABILITY; MANAGEMENT; INDICATOR; AGREEMENT; ACCURACY; PRELOAD; SURGERY;
D O I
10.1093/bja/aet116
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. A new calibrated pulse wave analysis method (VolumeView (TM)/EV1000 (TM), Edwards Lifesciences, Irvine, CA, USA) has been developed to continuously monitor cardiac output (CO). The aim of this study was to compare the performance of the VolumeView method, and of the PiCCO(2)(TM) pulse contour method (Pulsion Medical Systems, Munich, Germany), with reference transpulmonary thermodilution (TPTD) CO measurements. Methods. This was a prospective, multicentre observational study performed in the surgical and interdisciplinary intensive care units of four tertiary hospitals. Seventy-two critically ill patients were monitored with a central venous catheter, and a thermistor-tipped femoral arterial VolumeView (TM) catheter connected to the EV1000 (TM) monitor. After initial calibration by TPTD CO was continuously assessed using the VolumeView-CCO software (CCOvolumeview) during a 72 h period. TPTD was performed in order to obtain reference CO values (COREF). TPTD and arterial wave signals were transmitted to a PiCCO(2)(TM) monitor in order to obtain CCOPicco values. CCOvolumeview and CCOPiCCO were recorded over a 5 min interval before assessment of COTPTD. Bland-Altman analysis, %(errors), and concordance (trend analysis) were calculated. Results. A total of 338 matched sets of data were available for comparison. Bias for CCOvolumeview-COREF was -0.07 litre min(-1) and for CCOPiCCO-COREF +0.03 litre min(-1). Corresponding limits of agreement were 2.00 and 2.48 litre min(-1) (P<0.01), %(errors) 29 and 37%, respectively. Trending capabilities were comparable for both techniques. Conclusions. The performance of the new VolumeView (TM)-CCO method is as reliable as the PiCCO(2)(TM)-CCO pulse wave analysis in critically ill patients. However, an improved precision was observed with the VolumeView (TM) technique. Clinicaltrials.gov identifier. NCT01405040.
引用
收藏
页码:573 / 579
页数:7
相关论文
共 41 条
  • [1] Cardiac output monitoring: an integrative perspective
    Alhashemi, Jamal A.
    Cecconi, Maurizio
    Hofer, Christoph K.
    [J]. CRITICAL CARE, 2011, 15 (02):
  • [2] The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration
    Bein, Berthold
    Meybohm, Patrick
    Cavus, Erol
    Renner, Jochen
    Tonner, Peter H.
    Steinfath, Markus
    Scholz, Jens
    Doerges, Volker
    [J]. ANESTHESIA AND ANALGESIA, 2007, 105 (01) : 107 - 113
  • [3] Validation of a new transpulmonary thermodilution system to assess global end-diastolic volume and extravascular lung water
    Bendjelid, Karim
    Giraud, Raphael
    Siegenthaler, Nils
    Michard, Frederic
    [J]. CRITICAL CARE, 2010, 14 (06):
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    Critchley, LAH
    Critchley, JAJH
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) : 85 - 91
  • [6] A Critical Review of the Ability of Continuous Cardiac Output Monitors to Measure Trends in Cardiac Output
    Critchley, Lester A.
    Lee, Anna
    Ho, Anthony M. -H.
    [J]. ANESTHESIA AND ANALGESIA, 2010, 111 (05) : 1180 - 1192
  • [7] An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgery
    de Wilde, R. B. P.
    Schreuder, J. J.
    van den Berg, P. C. M.
    Jansen, J. R. C.
    [J]. ANAESTHESIA, 2007, 62 (08) : 760 - 768
  • [8] Della Rocca G, 2003, CAN J ANAESTH, V50, P707
  • [9] Comparison of pulmonary arterial thermodilution and arterial pulse contour analysis: Evaluation of a new algorithm
    Felbinger, TW
    Reuter, DA
    Eltzschig, HK
    Moerstedt, K
    Goedje, O
    Goetz, AE
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2002, 14 (04) : 296 - 301
  • [10] Gödje O, 2002, CRIT CARE MED, V30, P52