Intrapartum fetal asphyxia: study of umbilical cord blood lactate in relation to fetal heart rate patterns

被引:12
作者
Hamed, Hossam O. [1 ,2 ]
机构
[1] Assiut Univ, Dept Obstet & Gynecol, Women Hlth Ctr, Assiut, Egypt
[2] Qassim Univ, Dept Obstet & Gynecol, Buraydah, Saudi Arabia
关键词
Umbilical cord blood lactate; Fetal heart rate; Apgar score; APGAR SCORES; BASE DEFICIT; SCALP; PH; CARDIOTOCOGRAPHY;
D O I
10.1007/s00404-012-2694-7
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Purposes To correlate between umbilical artery cord blood lactate and acid-base status with intrapartum fetal heart rate monitoring, and to measure the reliability of umbilical cord blood lactate for prediction of early neonatal outcome. Methods Sixty-six participants with intrapartum abnormal fetal heart rate monitoring and 60 participants with normal intrapartum recordings were recruited. The abnormal recordings included late onset, atypical variable and simple variable decelerations. After delivery, the arterial cord blood lactate, pH, actual base excess (ABE), and Apgar score were measured in all participants. Results There was significant inverse correlation between cord lactate and pH and ABE in all participants (correlation coefficient = -0.7, p < 0.0001). The cord lactate was significantly higher in the late onset and atypical variable decelerations groups compared to control (p < 0.0001). There was no significant correlation between the Apgar score and blood lactate in all groups; however, the sensitivity and specificity of cord lactate to predict low score at 5 min were higher in comparison to cord pH. Conclusions Umbilical cord blood lactate is a reliable marker for intrapartum fetal asphyxia compared to cord acid-base status with better prediction for newborns with low Apgar score.
引用
收藏
页码:1067 / 1073
页数:7
相关论文
共 50 条
  • [21] Computerised analysis of intrapartum fetal heart rate patterns and adverse outcomes in the INFANT trial
    Steer, P. J.
    Kovar, I
    McKenzie, C.
    Griffin, M.
    Linsell, L.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2019, 126 (11) : 1354 - 1361
  • [22] Sparse Support Vector Machine for Intrapartum Fetal Heart Rate Classification
    Spilka, Jiri
    Frecon, Jordan
    Leonarduzzi, Roberto
    Pustelnik, Nelly
    Abry, Patrice
    Doret, Muriel
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2017, 21 (03) : 664 - 671
  • [23] Use of automated fetal heart rate analysis to identify risk factors for umbilical cord acidosis at birth
    de l'Aulnoit, A. Houze
    Genin, M.
    Boudet, S.
    Demailly, R.
    Ternynck, C.
    Babykina, G.
    de l'Aulnoit, D. Houze
    Beuscart, R.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2019, 115
  • [24] Midwives' and Women's Perception on Moyo Fetal Heart Rate Monitor for Intrapartum Fetal Heart Rate Monitoring; A Cross-Sectional Study
    Mdoe, Paschal
    Yeconia, Anita
    Buu, Fanuel
    Kusulla, Simeon
    Blacy, Ladislaus
    Guga, Godfrey
    Mduma, Estomih
    Kidanto, Hussein
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2020, 13 : 87 - 92
  • [25] Associations between fetal heart rate variability and umbilical cord occlusions-induced neural injury: An experimental study in a fetal sheep model
    Ghesquiere, Louise
    Perbet, Romain
    Lacan, Laure
    Hamoud, Yasmine
    Stichelbout, Morgane
    Sharma, Dyuti
    Nguyen, Sylvie
    Storme, Laurent
    Houfflin-Debarge, Veronique
    De Jonckheere, Julien
    Garabedian, Charles
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2022, 101 (07) : 758 - 770
  • [26] Intrapartum fetal heart rate patterns and perinatal outcome in chorioamnionitis at or beyond 34 weeks of gestation
    Muraoka, Junsuke
    Kodama, Yuki
    Ohashi, Masanao
    Goto, Tomoko
    Sameshima, Hiroshi
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2021, 47 (03) : 1110 - 1117
  • [27] Systematic Review of Intrapartum Fetal Heart Rate Spectral Analysis and an Application in the Detection of Fetal Acidemia
    Castro, Luisa
    Loureiro, Maria
    Henriques, Teresa S.
    Nunes, Ines
    FRONTIERS IN PEDIATRICS, 2021, 9
  • [28] Effectiveness of pulse oximetry versus fetal electrocardiography for the intrapartum evaluation of nonreassuring fetal heart rate
    Valverde, Mercedes
    Puertas, Alberto M.
    Lopez-Gallego, Maria F.
    Carrillo, Maria P.
    Aguilar, Maria T.
    Montoya, Francisco
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2011, 159 (02) : 333 - 337
  • [29] Fetal habituation to vibroacoustic stimulation in relation to fetal states and fetal heart rate parameters
    van Heteren, CF
    Boekkooi, PF
    Jongsma, HW
    Nijhuis, JG
    EARLY HUMAN DEVELOPMENT, 2001, 61 (02) : 135 - 145
  • [30] Interest of lactate micro-dosage in scalp and umbilical cord in cases of abnormal fetal heart rate during labor. Prospective study on 162 patients
    Paris, A.
    Maurice-Tison, S.
    Coatleven, F.
    Vandenbossche, F.
    Dallay, D.
    Horovitz, J.
    JOURNAL DE GYNECOLOGIE OBSTETRIQUE ET BIOLOGIE DE LA REPRODUCTION, 2012, 41 (04): : 324 - 332