Influence of angle κ on visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens

被引:24
作者
Garzon, Nuria [1 ,2 ]
Garcia-Montero, Maria [2 ]
Lopez-Artero, Esther [1 ]
Albarran-Diego, Cesar [3 ]
Perez-Cambrod, Rafael [4 ]
Illarramendi, Igor [5 ]
Poyales, Francisco [1 ]
机构
[1] IOA Madrid Innova Ocular, Galileo 104, Madrid 28003, Spain
[2] Univ Complutense Madrid, Dept Opt 2, Madrid, Spain
[3] Clin Oftalmol Dr Gonzalo Munoz, Valencia, Spain
[4] Vithas Medimar Int Hosp, Dept Ophthalmol Oftalmar, Alicante, Spain
[5] Innova Ocular, Madrid, Spain
关键词
PATIENT SATISFACTION; DISSATISFACTION;
D O I
10.1097/j.jcrs.0000000000000156
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate changes in angle kappa after the implantation of a trifocal intraocular lens (IOL) and to assess the postoperative outcomes of patients with different angle kappa values. Setting: IOA Madrid Innova Ocular, Madrid, Spain. Design: Prospective trial. Methods: Sixty-three eyes from 63 patients who had bilateral implantation of a diffractive trifocal IOL (POD F, PhysIOL) were included. Pupil offset was used as the best estimate of angle kappa and was measured using Pentacam (Oculus) preoperatively and at 3 months postoperatively. Postoperative refractive outcomes (sphere, cylinder, and manifest refraction spherical equivalent) and visual outcomes at far, intermediate, and near distance were assessed and compared between eyes with small pupil offset and eyes with large pupil offset. Quality of vision was assessed using a subjective questionnaire. Results: There was a significant decrease in pupil offset values postoperatively (mean: 0.197 +/- 0.12 mm) compared with those preoperatively (mean: 0.239 +/- 0.12 mm), with a mean decrease of -0.042 mm (P = .0002). The same significant decrease was found for both right and left eyes, when analyzed separately. No statistically significant difference was found in any of the refractive and visual acuity outcomes between eyes with small pupil offset and eyes with large pupil offset. The majority of patients (14 of 16) complaining of significant halos had eyes with small pupil offset. Conclusions: Large pupil offset did not negatively affect visual and refractive outcomes. The tolerance to larger pupil offset might be due to the IOL optical design, with the first diffractive ring being larger than other commonly used multifocal IOLs. More studies comparing various diffractive IOL models would be useful to confirm such hypothesis. Copyright (C) 2020 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:721 / 727
页数:7
相关论文
共 50 条
[31]   Comparison of visual and refractive outcomes after bilateral implantation of toric intraocular lenses with or without a multifocal component [J].
Hayashi, Ken ;
Masumoto, Miki ;
Takimoto, Minehiro .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01) :73-83
[32]   Visual performance, safety, and patient satisfaction after binocular clear lens extraction and trifocal intraocular lens implantation in Chinese presbyopic patients [J].
Chen, Lulu ;
Sun, Lu ;
Tang, Yongxiang ;
Sui, Wenda ;
Bian, Ailing ;
Zhang, Xia ;
Wang, Zaowen ;
Zhong, Yong ;
Zhang, Shunhua .
BMC OPHTHALMOLOGY, 2024, 24 (01)
[33]   Comparison of visual outcomes after bilateral implantation of two intraocular lenses with distinct diffractive optics [J].
de Medeiros, Andre Lins ;
Saraiva, Flavio Jones ;
Iguma, Camila Ishii ;
Kniggendorf, Danilo Varela ;
Alves, Guilherme ;
Pereira Dias Chaves, Mario Augusto ;
Vilar, Cesar ;
Pimenta Motta, Antonio Francisco ;
Carricondo, Pedro Carlos ;
Nakano, Celso Takashi ;
Nose, Walton ;
Hida, Wilson Takashi .
CLINICAL OPHTHALMOLOGY, 2019, 13 :1657-1663
[34]   Visual performance, safety and patient satisfaction after bilateral implantation of a trifocal intraocular lens in presbyopic patients without cataract [J].
Joaquín Fernández ;
José F. Alfonso Sánchez ;
Mark Nieradzik ;
Beatriz Valcárcel ;
Noemí Burguera ;
Alexander Kapp .
BMC Ophthalmology, 22
[35]   Visual performance, safety and patient satisfaction after bilateral implantation of a trifocal intraocular lens in presbyopic patients without cataract [J].
Fernandez, Joaquin ;
Alfonso Sanchez, Jose F. ;
Nieradzik, Mark ;
Valcarcel, Beatriz ;
Burguera, Noemi ;
Kapp, Alexander .
BMC OPHTHALMOLOGY, 2022, 22 (01)
[36]   Influence of angle kappa and angle alpha on visual quality after implantation of multifocal intraocular lenses [J].
Fu, Yana ;
Kou, Jiaojiao ;
Chen, Dongjie ;
Wang, Dandan ;
Zhao, Yinyin ;
Hu, Man ;
Lin, Xiaolei ;
Dai, Qi ;
Li, Junhua ;
Zhao, Yun-e .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (09) :1258-1264
[37]   The incidence and results of laser enhancement after cataract and refractive surgery with trifocal lens implantation [J].
Barakova, Drahomira ;
Jordanovova, Dana ;
Sramka, Martin ;
Kaluzakova, Adriana ;
Sajdikova, Martina .
BIOMEDICAL PAPERS-OLOMOUC, 2022, 166 (02) :222-227
[38]   Visual Performance of Two Diffractive Trifocal Intraocular Lenses: A Randomized Trial [J].
Hienert, Julius ;
Stjepanek, Kristina ;
Hirnschall, Nino ;
Ruiss, Manuel ;
Zwickl, Hannah ;
Findl, Oliver .
JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (07) :460-+
[39]   Influence of angle kappa-customized implantation of rotationally asymmetric multifocal intraocular lens on visual quality and patient satisfaction [J].
Liu, Yiyun ;
Gao, Yufei ;
Liu, Rongjun ;
Hu, Chenxi ;
Ma, Baikai ;
Miao, Jinhong ;
Luo, Jinhua ;
Qi, Hong .
ACTA OPHTHALMOLOGICA, 2020, 98 (06) :E734-E742
[40]   Visual and refractive outcomes of opposite clear corneal incision combined with rotationally asymmetric multifocal intraocular lens implantation [J].
Qin, Xiaoyu ;
Yao, Pengxiang ;
Wu, Xinyuan ;
Wu, Yang ;
Hong, Yufang ;
Chen, Zhenzong ;
Yuan, Yuanzhi .
FRONTIERS IN MEDICINE, 2024, 11