Reliability of an ear-bow arbitrary face-bow transfer instrument

被引:23
作者
Choi, DG
Bowley, JF
Marx, DB
Lee, S
机构
[1] Kyung Hee Univ, Dept Prosthodont, Coll Dent, Dongdaemoon Gu, Seoul 130702, South Korea
[2] Univ Nebraska, Med Ctr, Postgrad Prosthodont Program, Lincoln, NE 68583 USA
[3] Univ Nebraska, Inst Agr & Nat Resources, Dept Biometry, Lincoln, NE 68583 USA
[4] Univ Colorado, Hlth Sci Ctr, Denver, CO USA
关键词
D O I
10.1016/S0022-3913(99)70148-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Accuracy of techniques for recording the orientation of the maxillary arch to the articulation of the temporomandibular joints has been reported. The variability contributed by the dentist and the equipment within a technique may also contribute to technical error. Purpose. This study investigated the variability of a group of dentists who used an arbitrary ear-face-bow instrument to mount a maxillary cast. Material and methods. The same maxillary cast on a single experimental subject was mounted on an articulator with a common arbitrary ear-face-bow instrument. This cast was equipped with 4 reference points for the measurement of changes of spatial orientation of the cast, which were determined through coordinate measurements with a machinist's microscope. A repeated measures analysis of variance was used to determine statistically significant changes in spatial orientation with a Wilks' Lambda test to compare mean values. Results. A confidence interval of 95% demonstrated that any dentist might expect a range of +/-1.2 mm error in using this instrument/articulator combination. The 3 dentists did not demonstrate any significant differences in the spatial orientation of their mountings in the vertical or horizontal directions. However, there were significant differences in their mountings in linear distance changes of the patient's posterior right side. Conclusion. A range of inherent error attributable to the operator using this instrument was recorded.
引用
收藏
页码:150 / 156
页数:7
相关论文
共 13 条
[1]   RELIABILITY OF A FACEBOW TRANSFER PROCEDURE [J].
BOWLEY, JF ;
MICHAELS, GC ;
LAI, TW ;
LIN, PP .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (04) :491-498
[2]   RELIABILITY AND VALIDITY OF A TRANSVERSE HORIZONTAL AXIS LOCATION INSTRUMENT [J].
BOWLEY, JF ;
PIERCE, CJ .
JOURNAL OF PROSTHETIC DENTISTRY, 1990, 64 (06) :646-650
[3]  
Brotman DN, 1960, J PROSTHET DENT, V10, P631
[4]  
CAMPION GC, 1905, COSMOS DENT, V47, P39
[5]  
Cheong KT., 1984, J KOREAN ACAD PROSTH, V22, P72
[6]   A NEW METHOD OF MEASURING DIMENSIONAL CHANGE [J].
DABREO, EL ;
HERMAN, P .
JOURNAL OF PROSTHETIC DENTISTRY, 1991, 65 (05) :718-722
[7]   REASSESSMENT OF THE MANDIBULAR TRANSVERSE HORIZONTAL AXIS THEORY [J].
PRESTON, JD .
JOURNAL OF PROSTHETIC DENTISTRY, 1979, 41 (06) :605-613
[8]  
Schallhorn RG, 1957, J PROSTHET DENT, V3, P162
[9]   FACTORS OF OCCLUSION APPLICABLE TO RESTORATIVE DENTISTRY [J].
SCHUYLER, CH .
JOURNAL OF PROSTHETIC DENTISTRY, 1953, 3 (06) :772-782
[10]   ACCURACY OF AN EAR FACE-BOW [J].
TETERUCK, WR ;
LUNDEEN, HC .
JOURNAL OF PROSTHETIC DENTISTRY, 1966, 16 (06) :1039-&