Flue gas desulfurization effluents: An unexploited selenium resource

被引:46
作者
Cordoba, Patricia [1 ]
Staicu, Lucian C. [2 ]
机构
[1] Spanish Natl Res Council IDAEA CSIC, Inst Environm Assessment & Water Res, C Jordi Girona 18-26, Barcelona 08034, Spain
[2] Univ Politehn Bucuresti, Fac Appl Chem & Mat Sci, Polizu St 1-7, Bucharest 011061, Romania
关键词
Coal combustion; Flue Gas Desulfurization; Selenium; Resource recovery; Circular economy; FIRED POWER-PLANTS; TRACE-ELEMENT BEHAVIOR; THAUERA-SELENATIS; CIRCULAR ECONOMY; COAL COMBUSTION; BIOMINERALIZATION; FGD; RESPIRATION; REFINEMENT; SPECIATION;
D O I
10.1016/j.fuel.2018.03.052
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the advent of the Industrial Revolution, the natural cycle of selenium (Se) Se has been altered, thus leading to cases of severe environmental degradation. Nowadays, an important share of the global energy is generated by coal combustion. During this process, Se is concentrated in Flue Gas Desulfurization (FGD) wastewaters. FGD effluents can be treated by bioremediation, using bacterial metabolism to convert soluble and toxic forms of Se into elemental Se (nano) particles. Se and bacteria are intimately linked in a complex interplay since the element serves nutritional and metabolic energy generation functions, in addition to behaving as a powerful toxicant. In this article we explore the coupling of FGD treatment and resource recovery in the framework of circular economy. This approach reduces the burden of Se pollution for aquatic ecosystems, while also providing a way to recover a valuable resource, generating profit and offsetting the treatment costs.
引用
收藏
页码:268 / 276
页数:9
相关论文
共 75 条
[1]   Elucidation of the Mechanism of Reaction between S2O82-, Selenite and Mn2+ in Aqueous Solution and Limestone-Gypsum FGD Liquor [J].
Akiho, Hiroyuki ;
Ito, Shigeo ;
Matsuda, Hiromitsu ;
Yoshioka, Toshiaki .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (19) :11311-11317
[2]   Effect of oxidizing agents on selenate formation in a wet FGD [J].
Akiho, Hiroyuki ;
Ito, Shigeo ;
Matsuda, Hiromitsu .
FUEL, 2010, 89 (09) :2490-2495
[3]   Environmental impact of a coal combustion-desulphurisation plant:: Abatement capacity of desulphurisation process and environmental characterisation of combustion by-products [J].
Alvarez-Ayuso, E. ;
Querol, X. ;
Tomas, A. .
CHEMOSPHERE, 2006, 65 (11) :2009-2017
[4]  
[Anonymous], 2006, REFERENCE DOCUMENT B
[5]  
[Anonymous], 2014, CRC Handbook of Chemistry and Physics, V95th, P3, DOI [10.1201/b17118, DOI 10.1201/B17118]
[6]   A study of trace element behaviour in two modern coal-fired power plants - II. Trace element balances in two plants equipped with semi-dry flue gas desulphurisation facilities [J].
Aunela-Tapola, L ;
Hatanpaa, E ;
Hoffren, H ;
Laitinen, T ;
Larjava, K ;
Rasila, P ;
Tolvanen, M .
FUEL PROCESSING TECHNOLOGY, 1998, 55 (01) :13-34
[7]  
Babcock & Wilcox Power Generation Group (B& W), 1991, STEAM ITS GEN US, P980
[8]  
Bañuelos GS, 2017, PLANT ECOPHYSIOL, V11, P231, DOI 10.1007/978-3-319-56249-0_14
[9]  
BP, 2017, STAT REV WORLD EN
[10]   Colloidal Properties of Nanoparticular Biogenic Selenium Govern Environmental Fate and Bioremediation Effectiveness [J].
Buchs, Benjamin ;
Evangelou, Michael W. H. ;
Winkel, Lenny H. E. ;
Lenz, Markus .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (05) :2401-2407