Tracheal intubation using a Bullard laryngoscope for patients with a simulated difficult airway

被引:34
作者
MacQuarrie, K [1 ]
Hung, OR [1 ]
Law, JA [1 ]
机构
[1] Dalhousie Univ, Queen Elizabeth II Hlth Sci Ctr, Dept Anesthesia, Halifax, NS B3H 2Y9, Canada
来源
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 1999年 / 46卷 / 08期
关键词
D O I
10.1007/BF03013911
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose: To evaluate the utility and safety of orotracheal intubation in adult patients with simulated difficult airways using the Bullard Laryngoscope (BL). Methods: A rigid cervical collar was used to simulate the difficult airway. The study consisted of tw phases. Phase I evaluated the BL used in conjunction with an independently styletted endotracheal tube (ISETT) passed free-hand into the trachea. Phase II evaluated the new Multifunctional Intubating Stylet (MFIS), Forty patients were studied in each phase. Following induction of anesthesia a rigid cervical collar was applied and the laryngoscopic grade assessed. Tracheal intubation was then performed using the BL with either an ISETT or the MFIS. The total time to intubate, number of attempts, failures. hemodynamic changes during intubation were recorded. Results: The rigid collar effectively simulated a difficult laryngoscopy, 65% of patients had a grade 3 view. The success rates for tracheal intubation using the ISETT and MFIS were 88% and 83% respectively, The average times to intubation were similar for both intubating techniques (45.4 +/- 26.8 sec for the ISE-TT and 41.2 +/- 25.2 sec for the MFIS). Although there were minor hemodynamic changes, mucosal bleeding and sore throat following intubation, there were no major complications in any of the study patients, Conclusions: The BL, used with either an ISE-TT or the MFIS, is an effective and safe intubating device for patients with simulated restricted cervical spine movement. Further studies are needed to compare the effectiveness and safety of these two techniques in managing patients with a difficult airway.
引用
收藏
页码:760 / 765
页数:6
相关论文
共 21 条
[1]  
BORLAND LM, 1990, ANESTH ANALG, V70, P105
[2]   THE BULLARD LARYNGOSCOPE FOR EMERGENCY AIRWAY MANAGEMENT IN A MORBIDLY OBESE PARTURIENT [J].
COHN, AI ;
HART, RT ;
MCGRAW, SR ;
BLASS, NH .
ANESTHESIA AND ANALGESIA, 1995, 81 (04) :872-873
[3]   AWAKE ENDOTRACHEAL INTUBATION IN PATIENTS WITH CERVICAL-SPINE DISEASE - A COMPARISON OF THE BULLARD LARYNGOSCOPE AND THE FIBEROPTIC BRONCHOSCOPE [J].
COHN, AI ;
ZORNOW, MH .
ANESTHESIA AND ANALGESIA, 1995, 81 (06) :1283-1286
[4]   AWAKE INTUBATION OF THE ADULT TRACHEA USING THE BULLARD LARYNGOSCOPE [J].
COHN, AI ;
MCGRAW, SR ;
KING, WH .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1995, 42 (03) :246-248
[5]  
Cooper S.D., 1996, AIRWAY MANAGEMENT PR, P374
[6]  
COOPER SD, 1994, ANESTH ANALG, V79, P965
[7]   DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS [J].
CORMACK, RS ;
LEHANE, J .
ANAESTHESIA, 1984, 39 (11) :1105-1111
[8]   TECHNIQUES USING THE BULLARD LARYNGOSCOPE [J].
CROSBY, ET .
ANESTHESIA AND ANALGESIA, 1995, 81 (06) :1314-1315
[9]   Forced air warming can facilitate fiberoptic intubations [J].
Dunn, SM ;
Pulai, I .
ANESTHESIOLOGY, 1998, 88 (01) :282-282
[10]  
FINUCANE BT, 1996, PRINCIPLES AIRWAY MA