Finite element modelling of hybrid stabilization systems for the human lumbar spine

被引:14
|
作者
Demir, Eylul [1 ]
Eltes, Peter [2 ]
Castro, Andre P. G. [3 ]
Lacroix, Damien [4 ]
Toktas, Ihsan [1 ]
机构
[1] Ankara Yildirim Beyazit Univ, Fac Engn & Nat Sci, Mech Engn Dept, TR-06010 Ankara, Turkey
[2] Natl Ctr Spinal Disorders, Budapest, Hungary
[3] Univ Lisbon, Inst Super Tecn, IDMEC, Lisbon, Portugal
[4] Univ Sheffield, INSIGNEO Inst Silico Med, Sheffield, S Yorkshire, England
关键词
Lumbar spine; finite element modelling; range of motion; hybrid stabilization; intradiscal pressure; ADJACENT-SEGMENT DEGENERATION; DYNAMIC STABILIZATION; INTERBODY FUSION; DISC DISEASE; IN-VITRO; FIXATION; BEHAVIOR; DEVICE; SCREW; INSTRUMENTATION;
D O I
10.1177/0954411920946636
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intersomatic fusion is a very popular treatment for spinal diseases associated with intervertebral disc degeneration. The effects of three different hybrid stabilization systems on both range of motion and intradiscal pressure were investigated, as there is no consensus in the literature about the efficiency of these systems. Finite element simulations were designed to predict the variations of range of motion and intradiscal pressure from intact to implanted situations. After hybrid stabilization system implantation, L4-L5 level did not lose its motion completely, while L5-S1 had no mobility as a consequence of disc removal and fusion process. BalanC hybrid stabilization system represented higher mobility at the index level, reduced intradiscal pressure of adjacent level, but caused to increment in range of motion by 20% under axial rotation. Higher tendency by 93% to the failure was also detected under axial rotation. Dynesys hybrid stabilization system represented more restricted motion than BalanC, and negligible effects to the adjacent level. B-DYN hybrid stabilization system was the most rigid one among all three systems. It reduced intradiscal pressure and range of motion at the adjacent level except from motion under axial rotation being increased by 13%. Fracture risk of B-DYN and Dynesys Transition Optima components was low when compared with BalanC. Mobility of the adjacent level around axial direction should be taken into account in case of implantation with BalanC and B-DYN systems, as well as on the development of new designs. Having these findings in mind, it is clear that hybrid systems need to be further tested, both clinically and numerically, before being considered for common use.
引用
收藏
页码:1409 / 1420
页数:12
相关论文
共 50 条
  • [1] FEBio finite element models of the human lumbar spine
    Finley, Sean M.
    Brodke, Darrel S.
    Spina, Nicholas T.
    DeDen, Christine A.
    Ellis, Benjamin J.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2018, 21 (06) : 444 - 452
  • [2] STEPWISE VALIDATED FINITE ELEMENT MODEL OF THE HUMAN LUMBAR SPINE
    Coombs, Dana
    Bushelow, Michael
    Laz, Peter
    Rao, Milind
    Rullkoetter, Paul
    ASME 2013 CONFERENCE ON FRONTIERS IN MEDICAL DEVICES: APPLICATIONS OF COMPUTER MODELING AND SIMULATION, 2013,
  • [3] Biomechanical study of lumbar spine with dynamic stabilization device using finite element method
    Shin, Dong Suk
    Lee, Kunwoo
    Kim, Daniel
    COMPUTER-AIDED DESIGN, 2007, 39 (07) : 559 - 567
  • [4] A finite element model for predicting the biomechanical behaviour of the human lumbar spine
    Pitzen, T
    Geisler, F
    Matthis, D
    Müller-Storz, H
    Barbier, D
    Steudel, WI
    Feldges, A
    CONTROL ENGINEERING PRACTICE, 2002, 10 (01) : 83 - 90
  • [5] A finite element model for predicting the biomechanical behaviour of the human lumbar spine
    Pitzen, T
    Geisler, F
    Matthis, D
    Müller-Storz, H
    Caspar, W
    Ritz, R
    Steudel, WI
    MODELLING AND CONTROL IN BIOMEDICAL SYSTEMS 2000, 2000, : 19 - 22
  • [6] Biomechanical effects of laminectomies in the human lumbar spine: a finite element study
    Spina, Nicholas T.
    Moreno, Genesis S.
    Brodke, Darrel S.
    Finley, Sean M.
    Ellis, Benjamin J.
    SPINE JOURNAL, 2021, 21 (01): : 150 - 159
  • [7] Finite Element Modelling of the Human Lumbar Vertebrae for Dynamic Analysis
    Arjun, Raj S., I
    Goplani, Parth
    Suswaram, Pavan
    Chandrashekara, C., V
    MACHINES, MECHANISM AND ROBOTICS, INACOMM 2019, 2022, : 865 - 870
  • [8] Biomechanical Study of Lumbar Spine (L2-L4) Using Hybrid Stabilization Device - A Finite Element Analysis
    Jain, Pushpdant
    Khan, Mohammed Rajik
    INTERNATIONAL JOURNAL OF MANUFACTURING MATERIALS AND MECHANICAL ENGINEERING, 2020, 10 (01) : 20 - 32
  • [9] Finite element analysis of the spondylolysis in lumbar spine
    Wang, Jung-Pin
    Zhong, Zheng-Cheng
    Cheng, Cheng-Kung
    Chen, Chen-Sheng
    Yu, Chung-Hung
    Chang, Ting-Kuo
    Wei, Shun-Hwa
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2006, 16 (05) : 301 - 308
  • [10] The Effect of Muscle Direction on the Predictions of Finite Element Model of Human Lumbar Spine
    Zhu, Rui
    Niu, Wen-xin
    Wang, Zhi-peng
    Pei, Xiao-long
    He, Bin
    Zeng, Zhi-li
    Cheng, Li-ming
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018