Determination of iron(III) based on the fluorescence quenching of rhodamine B derivative

被引:59
作者
Du, Yanyan [1 ]
Chen, Min [1 ]
Zhang, Yingxue [1 ]
Luo, Feng [3 ]
He, Chunyan [1 ]
Li, Meijin [1 ]
Chen, Xi [2 ]
机构
[1] Fuzhou Univ, Dept Chem, Minist Educ, Key Lab Anal & Detect Technol Food Safety, Fuzhou 350002, Peoples R China
[2] Xiamen Univ, State Key Lab Marine Environm Sci, Xiamen 361005, Peoples R China
[3] Fujian Res Inst Metr Sci, Fuzhou 350003, Peoples R China
关键词
Rhodamine B derivative; Iron(III); Fluorescence; Quenching; AQUEOUS-SOLUTION; FE-III; IRON; CHEMOSENSOR; SWITCHES; PRECONCENTRATION; SPECTROMETRY; SENSORS; LEAD;
D O I
10.1016/j.talanta.2012.10.078
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method for determination of iron(III) has been developed using a kind of rhodamine B derivative fluorescent probe, rhodamine amide (RHA), in acidic HAc-NaAc buffer solution. In this approach, the heavy atom effect of I-3(-) was applied to quench the fluorescence of RHA. When iron(III) and KI coexisted in HAc-NaAc buffer solution, iron(III) reacted with the excess KI to produce I-3(-) that quenched the fluorescence of RHA through the formation of a non-fluorescence compound. The results showed that the fluorescence intensity decrease of RHA presented a good linear relationship with the iron(III) concentrations in the range from 0.5 to 5.0 mu mol L-1 with the correlation coefficient of 0.9970, and the detection limit was 0.3 mu mol L-1 iron(III). The approach was applied to determination of iron(III) in water samples, and the recovery was found to be from 80.7% to 100. 8%. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:261 / 265
页数:5
相关论文
共 37 条
[1]   Flow-injection determination of total iron in freshwater samples with neutralisation chemiluminescence [J].
Attiq-ur-Rehman ;
Yaqoob, Mohammad ;
Waseem, Amir ;
Nabi, Abdul .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (14) :1071-1080
[2]   Rhodamine-hydroxamate-based fluorescent chemosensor for FeIII [J].
Bae, Shinhyo ;
Tae, Jinsung .
TETRAHEDRON LETTERS, 2007, 48 (31) :5389-5392
[3]   Determination of iron in seawater by electrothermal atomic absorption spectrometry and atomic fluorescence spectrometry: A comparative study [J].
Cabon, J. Y. ;
Giamarchi, P. ;
Le Bihan, A. .
ANALYTICA CHIMICA ACTA, 2010, 664 (02) :114-120
[4]   Iron regulatory proteins in pathobiology [J].
Cairo, G ;
Pietrangelo, A .
BIOCHEMICAL JOURNAL, 2000, 352 :241-250
[5]   Luminescent sensors and switches in the early 21st century [J].
Callan, JF ;
de Silva, AP ;
Magri, DC .
TETRAHEDRON, 2005, 61 (36) :8551-8588
[6]   PRINCIPLES OF BIOINORGANIC CHEMISTRY - LIPPARD,SJ, BERG,JM [J].
CRABTREE, RH .
SCIENCE, 1994, 266 (5190) :1591-1592
[7]   Brain iron metabolism and its perturbation in neurological diseases [J].
Crichton, Robert R. ;
Dexter, David T. ;
Ward, Roberta J. .
MONATSHEFTE FUR CHEMIE, 2011, 142 (04) :341-355
[8]   High-accuracy determination of iron in seawater by isotope dilution multiple collector inductively coupled plasma mass spectrometry (ID-MC-ICP-MS) using nitrilotriacetic acid chelating resin for pre-concentration and matrix separation [J].
de Jong, Jeroen ;
Schoemann, Veronique ;
Lannuzel, Delphine ;
Tison, Jean-Louis ;
Mattielli, Nadine .
ANALYTICA CHIMICA ACTA, 2008, 623 (02) :126-139
[9]   PHOSPHORUS AND NITROGEN LIMITATION OF PRIMARY PRODUCTION IN A SIMULATED ESTUARINE GRADIENT [J].
DOERING, PH ;
OVIATT, CA ;
NOWICKI, BL ;
KLOS, EG ;
REED, LW .
MARINE ECOLOGY PROGRESS SERIES, 1995, 124 (1-3) :271-287
[10]   The synthesis of a rhodamine B schiff-base chemosensor and recognition properties for Fe3+ in neutral ethanol aqueous solution [J].
Dong, Lei ;
Wu, Chong ;
Zeng, Xi ;
Mu, Lan ;
Xue, Sai-Feng ;
Tao, Zhu ;
Zhang, Jian-Xin .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (01) :433-437