Experimental Investigating on On-line Monitoring Of Insulation System of Power Transformers

被引:0
|
作者
Shen, Ming [1 ]
Wu, Jiandong [1 ]
Yin, Yi [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Elect Engn, Sch Elect & Elect Engn, Shanghai 200240, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The insulation system of the transformer is a critical aspect of its health condition and the failure of the insulation system can make the transformers out of service. HV bushings and windings are the most important components of the transformer insulation system and failure statistics show that bushings and windings are the two of the major reasons for transformer failures, which motivates operators for continuous on-line monitoring of their insulation condition. Partial discharge (PD) measurements are also an important tool to assess the condition of the insulation system of the transformers, including the bushings and windings. The paper adopts a simple but effective method to not only monitor the bushings and the windings' health condition but detect the PD of the transformer. The 600 KHz similar to 1.2MHz sinusoidal signal based on direct digital synthesis (DDS), is applied on the bushings and the windings along with power frequency signal to assess the bushings and windings' health condition. Then the line-end and neutral-end high frequency currents are continuously measured by isolated precise current probes based on wide bandwidth Rogowski coils and related digital filtering methods. Meanwhile, the wide bandwidth Rogowski coils, which have double-channel outputs, can also detect the PD signals in the bushings and the windings. With the sinusoidal current data obtained from one channel of the probes, both the bushings' and the windings' insulation condition can be determined. And with the pulse current signal from PD obtained from the other channel of the probes, the PD of the bushings and the windings can be monitored all the time. Some simulations and experiments were made whose results showed that this detection method had high sensitivity and anti-interfere capability and it could wildly be used in insulation diagnose and partial discharge detection of power transformers.
引用
收藏
页码:327 / 330
页数:4
相关论文
共 50 条
  • [41] Key techniques for on-line monitoring system of insulation of capacitive equipment
    Wang, Jian
    Journal of Applied Sciences, 2013, 13 (16) : 3145 - 3152
  • [42] The design of circuit in on-line monitoring system for traction transformer insulation
    Tang, Hao
    Fan, Hanbin
    Wu, Guangning
    Li, Jinzhong
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 869 - +
  • [43] Research of on-line monitoring method for insulation condition of power transformer bushing
    Xia Jiuyun
    Qian Zheng
    Yu Hao
    Yao Junda
    SEVENTH INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS, 2016, 9903
  • [44] On-line coherency monitoring of power system oscillations
    Hiyama, T
    Suzuki, N
    Funakoshi, T
    2000 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-4, 2000, : 1839 - 1844
  • [45] Development of On-line Laser Power Monitoring System
    Ding, Chien-Fang
    Lee, Meng-Shiou
    Li, Kuan-Ming
    REAL-TIME MEASUREMENTS, ROGUE EVENTS, AND EMERGING APPLICATIONS, 2016, 9732
  • [46] On-line monitoring of temperature in power transformers using optimal linear combination of ANNs
    Pradhan, MK
    Ramu, TS
    CONFERENCE RECORD OF THE 2004 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2004, : 70 - 73
  • [47] On-line monitoring of HV bushings and current transformers
    Berler, Z
    Sokolov, V
    Prikhodko, V
    Bates, D
    Proceedings: Electrical Insulation Conference and Electrical Manufacturing Conference, 2005, : 61 - 66
  • [48] On-line multi-sensor monitoring system for insulation condition of oil-immersed power transformer
    Zhao, WB
    Zhang, GJ
    Sun, Y
    Yan, Z
    Xu, DK
    CONFERENCE RECORD OF THE 2004 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2004, : 89 - 92
  • [49] On-line monitoring system for leakage current of exterior insulation in power substation based on technology of virtual instrument
    Chen, Yu
    Qu, Bo
    Zhang, Shao-Feng
    Hu, Xue-Sheng
    Zhao, Yong
    Cheng, Yong-Hong
    Zhongguo Dianli/Electric Power, 2003, 36 (03):
  • [50] The Design of Zigbee-Based Transformer Insulation On-Line Monitoring System
    Tao, Feng-yuan
    Zhang, Dong
    Liao, Zhi-hua
    2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,