Experimental Investigating on On-line Monitoring Of Insulation System of Power Transformers

被引:0
|
作者
Shen, Ming [1 ]
Wu, Jiandong [1 ]
Yin, Yi [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Elect Engn, Sch Elect & Elect Engn, Shanghai 200240, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The insulation system of the transformer is a critical aspect of its health condition and the failure of the insulation system can make the transformers out of service. HV bushings and windings are the most important components of the transformer insulation system and failure statistics show that bushings and windings are the two of the major reasons for transformer failures, which motivates operators for continuous on-line monitoring of their insulation condition. Partial discharge (PD) measurements are also an important tool to assess the condition of the insulation system of the transformers, including the bushings and windings. The paper adopts a simple but effective method to not only monitor the bushings and the windings' health condition but detect the PD of the transformer. The 600 KHz similar to 1.2MHz sinusoidal signal based on direct digital synthesis (DDS), is applied on the bushings and the windings along with power frequency signal to assess the bushings and windings' health condition. Then the line-end and neutral-end high frequency currents are continuously measured by isolated precise current probes based on wide bandwidth Rogowski coils and related digital filtering methods. Meanwhile, the wide bandwidth Rogowski coils, which have double-channel outputs, can also detect the PD signals in the bushings and the windings. With the sinusoidal current data obtained from one channel of the probes, both the bushings' and the windings' insulation condition can be determined. And with the pulse current signal from PD obtained from the other channel of the probes, the PD of the bushings and the windings can be monitored all the time. Some simulations and experiments were made whose results showed that this detection method had high sensitivity and anti-interfere capability and it could wildly be used in insulation diagnose and partial discharge detection of power transformers.
引用
收藏
页码:327 / 330
页数:4
相关论文
共 50 条
  • [21] On-line Partial Discharge Monitoring of Substation Power Transformers
    Huzmezan, Mihai
    2022 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2022, : 347 - 352
  • [22] An On-line Monitoring Method for Winding Deformation of Power Transformers
    Liu, Xing-ping
    Chen, Min-you
    PROCEEDINGS OF THE 2013 IEEE 8TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2013, : 255 - 260
  • [23] Research on insulation condition monitoring system for power transformers
    Ren, Shuangzan
    Yang, Xu
    Yang, Wenhu
    Xi, Baofeng
    Cao, Xiaolong
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1005 - 1007
  • [24] Design of graphic system in insulation on-line monitoring system
    Wang, Nan
    Lu, Fangcheng
    Wang, Xin
    Zhang, Baodong
    2002, Science Press (28):
  • [25] On-line insulation monitoring of substation DC power supply
    Liupanshui Power Supply Bureau, Liupanshui 553000, China
    不详
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 2009, 12 (65-67+93):
  • [26] Practical experiences and benefits with on-line monitoring systems for power transformers
    Stirl, T
    Skrzypek, R
    ICEMS 2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1 AND 2, 2003, : 309 - 313
  • [27] Assessment of overload capacity of power transformers by on-line monitoring systems
    Tenbohlen, S
    Stirl, T
    Stach, M
    2001 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-3, 2001, : 329 - 334
  • [28] The new method of monitoring DC system insulation on-line
    Zhao, CY
    Jia, XF
    Hao, ZF
    IECON'01: 27TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, 2001, : 688 - 691
  • [29] Software design of insulation on-line monitoring and measuring system
    Guan, G.Z.
    Guo, W.
    Zhao, S.C.
    Zhongguo Dianli/Electric Power, 2001, 34 (10):
  • [30] On-line diagnostics of power transformers
    Mentlik, V.
    Prosr, P.
    Pihera, J.
    Polansky, R.
    Trnka, P.
    CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2006, : 546 - +