Development and validation of sensitive liquid chromatography/tandem mass spectrometry method for quantification of bendamustine in mouse brain tissue

被引:11
|
作者
He, Lei
Grecula, John C. [2 ,3 ]
Ling, Yonghua [2 ]
Enzerra, Michael D.
Ammirati, Mario [2 ,4 ]
Kendra, Kari [2 ,5 ]
Cavaliere, Robert [2 ,4 ]
Mayr, Nina [2 ,3 ]
McGregor, John [2 ,4 ]
Olencki, Thomas [2 ,5 ]
Mrozek, Ewa [2 ,5 ]
Matharbootham, Mani [2 ,6 ]
Oluigbo, Chima [2 ,4 ]
Phelps, Mitch A. [1 ,2 ]
机构
[1] Ohio State Univ, Coll Med, Coll Pharm, Dept Pharmacol,Div Pharmaceut, Columbus, OH 43210 USA
[2] Ohio State Univ, Ctr Comprehens Canc, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Med, Dept Radiat Oncol, Columbus, OH 43210 USA
[4] Ohio State Univ, Coll Med, Dept Neurosurg, Columbus, OH 43210 USA
[5] Ohio State Univ, Coll Med, Dept Med, Columbus, OH 43210 USA
[6] Ohio State Univ, Coll Med, Dept Anesthesiol, Columbus, OH 43210 USA
关键词
Bendamustine; Liquid chromatography-mass spectrometry; LC-MS/MS; Brain; BREAST-CANCER; HUMAN BILE; METABOLITES; BARRIER; IDENTIFICATION; METASTASES; LEUKEMIA; DELIVERY; THERAPY; PLASMA;
D O I
10.1016/j.jchromb.2012.08.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A liquid chromatography-tandem mass spectrometry method for quantification of bendamustine in mouse brain tissue was developed and fully validated. Methanol was used to precipitate proteins in brain tissue. Bendamustine and internal standard (chlorambucil) were separated with reverse-phase chromatography on a C-18 column with a gradient of water and 95% methanol in 0.1% formic acid. Positive mode electrospray ionization was applied with selected reaction monitoring to achieve 5 ng/ml lower limits of quantitation in mouse brain tissue. The calibration curve for bendamustine in mouse brain was linear between Sand 2000 ng/ml. The within- and between-batch accuracy and precision of the assay were within 15% at 10, 100 and 1000 ng/ml. The recovery and matrix effect of bendamustine in mouse brain tissue ranged from 41.1% to 51.6% and 107.4% to 110.3%, respectively. The validated method was then applied to quantitate bendamustine in an animal study. Results indicate the assay can be applied to evaluate bendamustine disposition in mouse brain tissue. This assay will be applied in the future to detect and quantify bendamustine in human brain tissue samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:141 / 144
页数:4
相关论文
共 50 条
  • [41] Development and validation of a simple and sensitive liquid chromatography-tandem mass spectrometry method for quantifying trimetazidine in human plasma
    Zhou, Gan
    Tan, Zhi-Rong
    Ouyang, Dong-Sheng
    Chen, Yao
    Guo, Dong
    Xie, Hai-Tang
    Liu, Ying-Zi
    Fan, Lan
    Deng, Han-Wu
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2010, 37 (04) : 501 - 505
  • [42] Development and validation of a sensitive method for hydromorphone in human plasma by normal phase liquid chromatography-tandem mass spectrometry
    Weng, ND
    Jiang, XY
    Newland, K
    Coe, R
    Lin, P
    Lee, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (04) : 697 - 704
  • [43] Quantification of lysophosphatidic acids in rat brain tissue by liquid chromatography-electrospray tandem mass spectrometry
    Aaltonen, Niina
    Laitinen, Jarmo T.
    Lehtonen, Marko
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (15-16): : 1145 - 1152
  • [44] Optimized liquid chromatography-tandem mass spectrometry for Otaplimastat quantification in rat plasma and brain tissue
    Lee, Seolhee
    Kim, Miri
    Oh, Ju-Hee
    Lee, Joo Hyun
    Shin, Naree
    Park, Taehoon
    Lee, Ji Hyeon
    Kim, Min Chang
    Lee, Young-Joo
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2019, 57 (03) : 258 - 264
  • [45] Sensitive and selective liquid chromatography-tandem mass spectrometry method for the quantification of aniracetam in human plasma
    Zhang, Jingjing
    Liang, Jidbi
    Tian, Yuan
    Zhang, Zunjian
    Chen, Yun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 858 (1-2): : 129 - 134
  • [46] Sensitive and reproducible liquid chromatography-tandem mass spectrometry method for quantification of sibutramine in human plasma
    Nirogi R.V.S.
    Kandikere V.
    Shukla M.
    Mudigonda K.
    Maurya S.
    Forensic Toxicology, 2007, 25 (1) : 30 - 36
  • [47] A sensitive liquid chromatography-tandem mass spectrometry method for the quantification of mometasone furoate in human plasma
    Sahasranaman, S
    Tang, YF
    Biniasz, D
    Hochhaus, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 819 (01): : 175 - 179
  • [48] Sensitive and selective liquid chromatography-tandem mass spectrometry method for the quantification of azithromycin in human plasma
    Nirogi, RVS
    Kandikere, VN
    Shukla, M
    Mudigonda, K
    Maurya, S
    Boosi, R
    Yerramilli, A
    ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) : 1 - 8
  • [49] Development of highly sensitive quantification method for testosterone and dihydrotestosterone in human serum and prostate tissue by liquid chromatography-electrospray ionization tandem mass spectrometry
    Yamashita, Kouwa
    Miyashiro, Yoshimichi
    Maekubo, Hitoe
    Okuyama, Mitsunobu
    Honma, Seijiro
    Takahashi, Madoka
    Numazawa, Mitsuteru
    STEROIDS, 2009, 74 (12) : 920 - 926
  • [50] Development and validation of a highly sensitive liquid chromatography/mass spectrometry method for simultaneous quantification of lenalidomide and flavopiridol in human plasma
    Liu, Qing
    Farley, Katherine L.
    Johnson, Amy J.
    Muthusamy, Natarajan
    Hofmeister, Craig C.
    Blum, Kristie A.
    Schaaf, Larry J.
    Grever, Michael R.
    Byrd, John C.
    Dalton, James T.
    Phelps, Mitch A.