Development and validation of sensitive liquid chromatography/tandem mass spectrometry method for quantification of bendamustine in mouse brain tissue

被引:11
|
作者
He, Lei
Grecula, John C. [2 ,3 ]
Ling, Yonghua [2 ]
Enzerra, Michael D.
Ammirati, Mario [2 ,4 ]
Kendra, Kari [2 ,5 ]
Cavaliere, Robert [2 ,4 ]
Mayr, Nina [2 ,3 ]
McGregor, John [2 ,4 ]
Olencki, Thomas [2 ,5 ]
Mrozek, Ewa [2 ,5 ]
Matharbootham, Mani [2 ,6 ]
Oluigbo, Chima [2 ,4 ]
Phelps, Mitch A. [1 ,2 ]
机构
[1] Ohio State Univ, Coll Med, Coll Pharm, Dept Pharmacol,Div Pharmaceut, Columbus, OH 43210 USA
[2] Ohio State Univ, Ctr Comprehens Canc, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Med, Dept Radiat Oncol, Columbus, OH 43210 USA
[4] Ohio State Univ, Coll Med, Dept Neurosurg, Columbus, OH 43210 USA
[5] Ohio State Univ, Coll Med, Dept Med, Columbus, OH 43210 USA
[6] Ohio State Univ, Coll Med, Dept Anesthesiol, Columbus, OH 43210 USA
关键词
Bendamustine; Liquid chromatography-mass spectrometry; LC-MS/MS; Brain; BREAST-CANCER; HUMAN BILE; METABOLITES; BARRIER; IDENTIFICATION; METASTASES; LEUKEMIA; DELIVERY; THERAPY; PLASMA;
D O I
10.1016/j.jchromb.2012.08.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A liquid chromatography-tandem mass spectrometry method for quantification of bendamustine in mouse brain tissue was developed and fully validated. Methanol was used to precipitate proteins in brain tissue. Bendamustine and internal standard (chlorambucil) were separated with reverse-phase chromatography on a C-18 column with a gradient of water and 95% methanol in 0.1% formic acid. Positive mode electrospray ionization was applied with selected reaction monitoring to achieve 5 ng/ml lower limits of quantitation in mouse brain tissue. The calibration curve for bendamustine in mouse brain was linear between Sand 2000 ng/ml. The within- and between-batch accuracy and precision of the assay were within 15% at 10, 100 and 1000 ng/ml. The recovery and matrix effect of bendamustine in mouse brain tissue ranged from 41.1% to 51.6% and 107.4% to 110.3%, respectively. The validated method was then applied to quantitate bendamustine in an animal study. Results indicate the assay can be applied to evaluate bendamustine disposition in mouse brain tissue. This assay will be applied in the future to detect and quantify bendamustine in human brain tissue samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:141 / 144
页数:4
相关论文
共 50 条
  • [31] A Liquid Chromatography with Tandem Mass Spectrometry Bio-Analytical Method Development and Validation for the Quantification of Zanamivir in Biological Matrices
    Mohammad, A. S.
    Bangaru, Jayanthi
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2021, 83 (05) : 974 - 981
  • [32] Development and validation of ivermectin quantification method in volumetric absorptive microsampling using liquid chromatography-tandem mass spectrometry
    Harahap, Yahdiana
    Salsabila, Salsabila
    Saputri, Febrina Amelia
    HELIYON, 2024, 10 (08)
  • [33] Bioanalytical method development, validation and quantification of flupirtine maleate in rat plasma by liquid chromatography-tandem mass spectrometry
    Kandasamy, Karthikeyan
    Gowdra, Vasantharaju Surenahalli
    Nammalvar, Hariprabhu
    Govindarajan, Arul Kumaran Kottur S.
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2011, 61 (12): : 693 - 699
  • [34] Development and validation of a liquid chromatography tandem mass spectrometry method for the analysis of macrolides in honey
    Berrada, H.
    Juan, C.
    Igualada, C.
    Font, G.
    TOXICOLOGY LETTERS, 2010, 196 : S343 - S343
  • [35] Quantification of clopidogrel in human plasma by sensitive liquid chromatography/tandem mass spectrometry
    Nirogi, RVS
    Kandikere, VN
    Shukla, M
    Mudigonda, K
    Maurya, S
    Boosi, R
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (11) : 1695 - 1700
  • [36] A sensitive liquid chromatography-tandem mass spectrometry method for the quantification of valacyclovir and its metabolite acyclovir in mouse and human plasma
    Shi, Jian
    Hu, Yongjun
    Smith, David E.
    Zhu, Hao-Jie
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1092 : 447 - 452
  • [37] Validation of a sensitive assay for thiocoraline in mouse plasma using liquid chromatography-tandem mass spectrometry
    Yin, JM
    Aviles, P
    Lee, W
    Ly, C
    Guillen, MJ
    Calvo, P
    Manzanares, I
    Faircloth, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 794 (01): : 89 - 98
  • [38] Sensitive isotope dilution liquid chromatography/tandem mass spectrometry method for quantitative analysis of bumetanide in serum and brain tissue
    Li, Yijun
    Cleary, Ryan
    Kellogg, Mark
    Soul, Janet S.
    Berry, Gerard T.
    Jensen, Frances E.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (13-14): : 998 - 1002
  • [39] Addressing a major interference in the quantification of psilocin in mouse plasma: Development of a validated liquid chromatography tandem mass spectrometry method
    Khajavinia, Amir
    Michel, Deborah
    Ezeaka, Udoka C.
    Purves, Randy W.
    Laprairie, Robert B.
    El-Aneed, Anas
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1730
  • [40] Development and validation of a sensitive liquid chromatography-tandem mass spectrometry method for the determination of paeoniflorin in rat brain and its application to pharmacokinetic study
    Xia, Su-Mei
    Shen, Rong
    Sun, Xue-Ying
    Shen, Li-Li
    Yang, Yi-Ming
    Ke, Yin
    Wang, Yun
    Chen, Dong-Ying
    Han, Xing-Mei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 857 (01): : 32 - 39