Development and validation of sensitive liquid chromatography/tandem mass spectrometry method for quantification of bendamustine in mouse brain tissue

被引:11
|
作者
He, Lei
Grecula, John C. [2 ,3 ]
Ling, Yonghua [2 ]
Enzerra, Michael D.
Ammirati, Mario [2 ,4 ]
Kendra, Kari [2 ,5 ]
Cavaliere, Robert [2 ,4 ]
Mayr, Nina [2 ,3 ]
McGregor, John [2 ,4 ]
Olencki, Thomas [2 ,5 ]
Mrozek, Ewa [2 ,5 ]
Matharbootham, Mani [2 ,6 ]
Oluigbo, Chima [2 ,4 ]
Phelps, Mitch A. [1 ,2 ]
机构
[1] Ohio State Univ, Coll Med, Coll Pharm, Dept Pharmacol,Div Pharmaceut, Columbus, OH 43210 USA
[2] Ohio State Univ, Ctr Comprehens Canc, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Med, Dept Radiat Oncol, Columbus, OH 43210 USA
[4] Ohio State Univ, Coll Med, Dept Neurosurg, Columbus, OH 43210 USA
[5] Ohio State Univ, Coll Med, Dept Med, Columbus, OH 43210 USA
[6] Ohio State Univ, Coll Med, Dept Anesthesiol, Columbus, OH 43210 USA
关键词
Bendamustine; Liquid chromatography-mass spectrometry; LC-MS/MS; Brain; BREAST-CANCER; HUMAN BILE; METABOLITES; BARRIER; IDENTIFICATION; METASTASES; LEUKEMIA; DELIVERY; THERAPY; PLASMA;
D O I
10.1016/j.jchromb.2012.08.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A liquid chromatography-tandem mass spectrometry method for quantification of bendamustine in mouse brain tissue was developed and fully validated. Methanol was used to precipitate proteins in brain tissue. Bendamustine and internal standard (chlorambucil) were separated with reverse-phase chromatography on a C-18 column with a gradient of water and 95% methanol in 0.1% formic acid. Positive mode electrospray ionization was applied with selected reaction monitoring to achieve 5 ng/ml lower limits of quantitation in mouse brain tissue. The calibration curve for bendamustine in mouse brain was linear between Sand 2000 ng/ml. The within- and between-batch accuracy and precision of the assay were within 15% at 10, 100 and 1000 ng/ml. The recovery and matrix effect of bendamustine in mouse brain tissue ranged from 41.1% to 51.6% and 107.4% to 110.3%, respectively. The validated method was then applied to quantitate bendamustine in an animal study. Results indicate the assay can be applied to evaluate bendamustine disposition in mouse brain tissue. This assay will be applied in the future to detect and quantify bendamustine in human brain tissue samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:141 / 144
页数:4
相关论文
共 50 条
  • [1] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of temozolomide in mouse brain tissue
    Kakarla, Raghavi
    Yacoub, Kimberly
    Bearden, Rebecca L.
    Zhou, Aimin
    Mukherjee, Sanjib
    Shan, Frank Y.
    Guo, Baochuan
    SEPARATION SCIENCE PLUS, 2023, 6 (04)
  • [2] Sensitive liquid chromatography/mass spectrometry methods for quantification of pomalidomide in mouse plasma and brain tissue
    Jiang, Yao
    Wang, Jiang
    Rozewski, Darlene M.
    Kolli, Shamalatha
    Wu, Chia-Hsien
    Chen, Ching-Shih
    Yang, Xiaoxia
    Hofmeister, Craig C.
    Byrd, John C.
    Johnson, Amy J.
    Phelps, Mitch A.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 88 : 262 - 268
  • [3] Development and validation of a rapid and sensitive liquid chromatography-tandem mass spectrometry method for benvitimod quantification in human plasma
    Zhao, Libo
    Zhu, Baoying
    Chen, Xin
    Chen, Genghui
    Chen, Haibo
    Li, Yuzhen
    Jing, Shan
    Fang, Yi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 885 : 160 - 165
  • [4] Development and validation of a fast and reliable method for the quantification of glucagon by liquid chromatography and tandem mass spectrometry
    Farre-Segura, Jordi
    Fabregat-Cabello, Neus
    Calaprice, Chiara
    Nyssen, Laurent
    Peeters, Stephanie
    Le Goff, Caroline
    Cavalier, Etienne
    CLINICA CHIMICA ACTA, 2021, 512 : 156 - 165
  • [5] Development and Validation of Liquid Chromatography-Tandem Mass Spectrometry Method for Detection and Quantification of Flunisolide in Tissue Culture Medium
    Jadhav, M. P.
    Tang, Y.
    Hochhaus, G.
    ANALYTICAL LETTERS, 2013, 46 (09) : 1355 - 1363
  • [6] Quantification of Neurotransmitters in Mouse Brain Tissue by Using Liquid Chromatography Coupled Electrospray Tandem Mass Spectrometry
    Kim, Tae-Hyun
    Choi, Juhee
    Kim, Hyung-Gun
    Kim, Hak Rim
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2014, 2014
  • [7] Sensitive liquid chromatography tandem mass spectrometry method for the quantification of Quetiapine in plasma
    Nirogi, Ramakrishna
    Bhyrapuneni, Gopinadh
    Kandikere, Vishwottam
    Mudigonda, Koteshwara
    Ajjala, Devender
    Mukkanti, K.
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (10) : 1043 - 1055
  • [8] Liquid chromatography-tandem mass spectrometry method for the quantification of dimebon in rat plasma and brain tissue
    Nirogi, Ramakrishna
    Kandikere, Vishwottam
    Mudigonda, Koteshwara
    Komarneni, Prashanth
    Boggavarapu, Rajeshkumar
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (29): : 3563 - 3571
  • [9] Development and validation of a liquid chromatography/tandem mass spectrometry method for the quantification of flucloxacillin and cloxacillin in microdialysis samples
    Larmene-Beld, Karin H. M.
    Vries-Koenjer, Marie-Therese L. M.
    ter Horst, Peter G. J.
    Hospes, Wobbe
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (08) : 1096 - 1101
  • [10] Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of opiorphin in human saliva
    Brkljacic, Lidija
    Sabalic, Maja
    Salaric, Ivan
    Jeric, Ivanka
    Alajbeg, Ivan
    Nemet, Ina
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (32): : 3920 - 3926