Acoustic Hearing Can Interfere With Single-Sided Deafness Cochlear-Implant Speech Perception

被引:22
作者
Bernstein, Joshua G. W. [1 ]
Stakhovskaya, Olga A. [2 ]
Jensen, Kenneth Kragh [1 ]
Goupell, Matthew J. [2 ]
机构
[1] Walter Reed Natl Mil Med Ctr, Natl Mil Audiol & Speech Pathol Ctr, 4954 N Palmer Rd, Bethesda, MD 20889 USA
[2] Univ Maryland, Dept Hearing & Speech Sci, College Pk, MD 20742 USA
基金
美国国家卫生研究院;
关键词
Aging; Asymmetric hearing loss; Auditory prosthesis; Binaural hearing; Informational masking; Selective attention; Unilateral hearing loss; ASYMMETRIC HEARING; UNILATERAL DEAFNESS; BINAURAL HEARING; HEAD SHADOW; RECOGNITION; ADULTS; LOCALIZATION; MASKING; REPRESENTATION; STIMULATION;
D O I
10.1097/AUD.0000000000000805
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: Cochlear implants (CIs) restore some spatial advantages for speech understanding in noise to individuals with single-sided deafness (SSD). In addition to a head-shadow advantage when the CI ear has a better signal-to-noise ratio, a CI can also provide a binaural advantage in certain situations, facilitating the perceptual separation of spatially separated concurrent voices. While some bilateral-CI listeners show a similar binaural advantage, bilateral-CI listeners with relatively large asymmetries in monaural speech understanding can instead experience contralateral speech interference. Based on the interference previously observed for asymmetric bilateral-CI listeners, this study tested the hypothesis that in a multiple-talker situation, the acoustic ear would interfere with rather than improve CI speech understanding for SSD-CI listeners. Design: Experiment 1 measured CI-ear speech understanding in the presence of competing speech or noise for 13 SSD-CI listeners. Target speech from the closed-set coordinate response-measure corpus was presented to the CI ear along with one same-gender competing talker or stationary noise at target-to-masker ratios between -8 and 20 dB. The acoustic ear was presented with silence (monaural condition) or with a copy of the competing speech or noise (bilateral condition). Experiment 2 tested a subset of 6 listeners in the reverse configuration for which SSD-CI listeners have previously shown a binaural benefit (target and competing speech presented to the acoustic ear; silence or competing speech presented to the CI ear). Experiment 3 examined the possible influence of a methodological difference between experiments 1 and 2: whether the competing talker spoke keywords that were inside or outside the response set. For each experiment, the data were analyzed using repeated-measures logistic regression. For experiment 1, a correlation analysis compared the difference between bilateral and monaural speech-understanding scores to several listener-specific factors: speech understanding in the CI ear, preimplantation duration of deafness, duration of CI experience, ear of deafness (left/right), acoustic-ear audiometric thresholds, and listener age. Results: In experiment 1, presenting a copy of the competing speech to the acoustic ear reduced CI speech-understanding scores for target-to-masker ratios >= 4 dB. This interference effect was limited to competing-speech conditions and was not observed for a noise masker. There was dramatic intersubject variability in the magnitude of the interference (range: 1 to 43 rationalized arcsine units), which was found to be significantly correlated with listener age. The interference effect contrasted sharply with the reverse configuration (experiment 2), whereby presenting a copy of the competing speech to the contralateral CI ear significantly improved performance relative to monaural acoustic-ear performance. Keyword condition (experiment 3) did not influence the observed pattern of interference. Conclusions: Most SSD-CI listeners experienced interference when they attended to the CI ear and competing speech was added to the acoustic ear, although there was a large amount of intersubject variability in the magnitude of the effect, with older listeners particularly susceptible to interference. While further research is needed to investigate these effects under free-field listening conditions, these results suggest that for certain spatial configurations in a multiple-talker situation, contralateral speech interference could reduce the benefit that an SSD-CI otherwise provides.
引用
收藏
页码:747 / 761
页数:15
相关论文
共 41 条
  • [11] Differential representation of speech sounds in the human cerebral hemispheres
    Firszt, JB
    Ulmer, JL
    Gaggl, W
    [J]. ANATOMICAL RECORD PART A-DISCOVERIES IN MOLECULAR CELLULAR AND EVOLUTIONARY BIOLOGY, 2006, 288A (04): : 345 - 357
  • [12] Unilateral Hearing Loss: Understanding Speech Recognition and Localization Variability-Implications for Cochlear Implant Candidacy
    Firszt, Jill B.
    Reeder, Ruth M.
    Holden, Laura K.
    [J]. EAR AND HEARING, 2017, 38 (02) : 159 - 173
  • [13] Cochlear Implantation in Adults With Asymmetric Hearing Loss
    Firszt, Jill B.
    Holden, Laura K.
    Reeder, Ruth M.
    Cowdrey, Lisa
    King, Sarah
    [J]. EAR AND HEARING, 2012, 33 (04) : 521 - 533
  • [14] Spatial release from informational masking in speech recognition
    Freyman, RL
    Balakrishnan, U
    Helfer, KS
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2001, 109 (05) : 2112 - 2122
  • [15] Speech recognition materials and ceiling effects: Considerations for cochlear implant programs
    Gifford, Rene H.
    Shallop, Jon K.
    Peterson, Anna Mary
    [J]. AUDIOLOGY AND NEURO-OTOLOGY, 2008, 13 (03) : 193 - 205
  • [16] Asymmetric Hearing During Development: The Aural Preference Syndrome and Treatment Options
    Gordon, Karen
    Henkin, Yael
    Kral, Andrej
    [J]. PEDIATRICS, 2015, 136 (01) : 141 - 153
  • [17] Bilateral input protects the cortex from unilaterally-driven reorganization in children who are deaf
    Gordon, Karen A.
    Wong, Daniel D. E.
    Papsin, Blake C.
    [J]. BRAIN, 2013, 136 : 1609 - 1625
  • [18] Contralateral Interference Caused by Binaurally Presented Competing Speech in Adult Bilateral Cochlear-Implant Users
    Goupell, Matthew J.
    Stakhovskaya, Olga A.
    Bernstein, Joshua G. W.
    [J]. EAR AND HEARING, 2018, 39 (01) : 110 - 123
  • [19] Spatial attention in bilateral cochlear-implant users
    Goupell, Matthew J.
    Kan, Alan
    Litovsky, Ruth Y.
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2016, 140 (03) : 1652 - 1662
  • [20] The effect of long-term unilateral deafness on the activation pattern in the auditory cortices of French-native speakers: influence of deafness side
    Hanss, Julien
    Veuillet, Evelyne
    Adjout, Kamel
    Besle, Julien
    Collet, Lionel
    Thai-Van, Hung
    [J]. BMC NEUROSCIENCE, 2009, 10