Assessment of PM2.5 monitoring using MicroPEM: A validation study in a city with elevated PM2.5 levels

被引:21
作者
Du, Yanjun [1 ]
Wang, Qin [1 ]
Sun, Qinghua [1 ]
Zhang, Ting [2 ]
Li, Tiantian [1 ]
Yan, Beizhan [3 ]
机构
[1] Chinese Ctr Dis Control & Prevent, Natl Inst Environm Hlth, 7 Panjiayuan Nanli, Beijing 100021, Peoples R China
[2] Nanjing Univ, Minist Educ, Key Lab Surficial Geochem, 163 Xianlin Ave, Nanjing 210023, Jiangsu, Peoples R China
[3] Columbia Univ, Lamont Doherty Earth Observ, 16 Rt 9W, Palisades, NY 10964 USA
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
PM2.5; Air monitor; MicroPEM; Calibration; Gravimetric; Real-time data; FINE PARTICULATE MATTER; PERSONAL EXPOSURE; AIR-POLLUTION; INDOOR; HAZE; PERFORMANCE; PM10;
D O I
10.1016/j.ecoenv.2019.01.002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Portable monitors such as MicroPEM can accurately characterize personal exposure of pollutants, which is critical for linking exposure and health effects of air pollution. The RTI (RTI International, Research Triangle Park, NC, USA) MicroPEM V3.2A provides both real-time fine particulate matter (PM2.5) concentrations and time-integrated PM samples collected onto Teflon filters that can be used to correct real-time data as well as allow further lab chemical analysis of species on filters (e.g., metal, black carbon). Due to the optical reflectivity of local PM sources can be very different from available standard reference particles used for calibration by RTI, there is a need for gravimetric correction and validation at each study location. However, assessments of MicroPEM have been limited in locations with severe air pollution, such as Beijing. We selected a variety of weather and air quality conditions, including both clear and hazy days in Beijing, to compare PM2.5 data among MicroPEMs as well as between MicroPEM and other types of samplers. We also compared MicroPEM real-time PM2.5 concentrations with data from nearby fixed-sites. The results show MicroPEM performed well across a wide range of PM2.5 concentrations (6-461 mu g/m(3)) and MicroPEM data, after gravimetric correction, were consistent with those from moderate-volume samplers. Good agreement was also found between real-time data from MicroPEM and fixed-site data. The present study covered a wide range of pollution levels in actual environments and validated the usage of MicroPEM as a PM2.5 monitor in locations with elevated PM2.5 levels.
引用
收藏
页码:518 / 522
页数:5
相关论文
共 37 条
[1]   Controlled experiments measuring personal exposure to PM2.5 in close proximity to cigarette smoking [J].
Acevedo-Bolton, V. ;
Ott, W. R. ;
Cheng, K. -C. ;
Jiang, R. -T. ;
Klepeis, N. E. ;
Hildemann, L. M. .
INDOOR AIR, 2014, 24 (02) :199-212
[2]  
Beijing Municipal Environmental monitoring center (BJMEMC), AIR QUAL BEIJ
[3]   Year-long continuous personal exposure to PM2.5 recorded by a fast responding portable nephelometer [J].
Branis, Martin ;
Kolomaznikova, Jana .
ATMOSPHERIC ENVIRONMENT, 2010, 44 (24) :2865-2872
[4]  
Chakrabarti B., 2014, ATMOS ENVIRON, V38, P3329
[5]   Chemical characterization and sources of personal exposure to fine particulate matter (PM2.5) in the megacity of Guangzhou, China [J].
Chen, Xiao-Cui ;
Jahn, Heiko J. ;
Engling, Guenter ;
Ward, Tony J. ;
Kraemer, Alexander ;
Ho, Kin-Fai ;
Yim, S. H. L. ;
Chan, Chuen-Yu .
ENVIRONMENTAL POLLUTION, 2017, 231 :871-881
[6]  
China Meteorological Data Service Center (CMDC), DAIL DAT CLIM CHIN
[7]   Personal exposure to PM2.5, genetic variants and DNA damage: A multi-center population-based study in Chinese [J].
Chu, Minjie ;
Sun, Chongqi ;
Chen, Weihong ;
Jin, Guangfu ;
Gong, Jianhang ;
Zhu, Meng ;
Yuan, Jing ;
Dai, Juncheng ;
Wang, Meilin ;
Pan, Yun ;
Song, Yuanchao ;
Ding, Xiaojie ;
Guo, Xuejiang ;
Du, Mulong ;
Xia, Yankai ;
Kan, Haidong ;
Zhang, Zhengdong ;
Hu, Zhibin ;
Wu, Tangchun ;
Shen, Hongbing .
TOXICOLOGY LETTERS, 2015, 235 (03) :172-178
[8]   Modeling of residential indoor PM2.5 exposure in 37 counties in China [J].
Du, Yanjun ;
Wang, Yanwen ;
Du, Zonghao ;
Zhang, Yi ;
Xu, Dandan ;
Li, Tiantian .
ENVIRONMENTAL POLLUTION, 2018, 238 :691-697
[9]  
Du YJ., 2016, HEALTH, V9, P439, DOI DOI 10.1007/S11869-015-0387-7
[10]   Field performance of a nephelometer in rural kitchens: effects of high humidity excursions and correlations to gravimetric analyses [J].
Fischer, Susan L. ;
Koshland, Catherine P. .
JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2007, 17 (02) :141-150