Sinusoidally-driven flat-ended indentation of time-dependent materials: Asymptotic models for low and high rate loading

被引:7
作者
Argatov, I. [1 ]
机构
[1] Aberystwyth Univ, Inst Math & Phys, Ceredigion SY23 3BZ, Wales
关键词
Viscoelastic contact problem; Dynamic indentation modulus; Pulsatile indentation modulus; Indentation test; Asymptotic model; ATOMIC-FORCE MICROSCOPY; ARTICULAR-CARTILAGE; VISCOELASTIC PROPERTIES; MECHANICAL-PROPERTIES; PUNCH INDENTATION; RIGID SUBSTRATE; VALIDATION; INSTRUMENT; STIFFNESS; PROBE;
D O I
10.1016/j.mechmat.2011.12.010
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In recent years, a sinusoidally-driven indentation test was shown to be effective for viability characterization of articular cartilage. The mathematical analysis of dynamic indentation experiments for a time-dependent material requires a complete understanding of the material damping characteristics. It is assumed that the mechanical response of the articular cartilage layer can be described in the framework of viscoelastic model with time-independent Poisson's ratio such that the overall constitutive behavior is expressed in terms of the complex modulus. Based on the elastic-viscoelastic correspondence principle, the governing integral equation of the associated dynamic contact problem is formulated, and closed-form analytical solutions for the integral characteristics of the indentation test are obtained. An asymptotic modeling approach is then applied for analyzing and interpreting the results of the dynamic indentation test in terms of the storage modulus and the loss angle of the viscoelastic material. The behavior of the dynamic and pulsatile indentation moduli has been studied in detail. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:56 / 70
页数:15
相关论文
共 29 条
  • [1] [Anonymous], 1974, ASYMPTOTIC EXPANSION
  • [2] The accuracy and reliability of a novel handheld dynamic indentation probe for analysing articular cartilage
    Appleyard, RC
    Swain, MV
    Khanna, S
    Murrell, GAC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02) : 541 - 550
  • [3] Indentation testing of human cartilage - Sensitivity to articular surface degeneration
    Bae, WC
    Temple, MA
    Amiel, D
    Coutts, RD
    Niederauer, GG
    Sah, RL
    [J]. ARTHRITIS AND RHEUMATISM, 2003, 48 (12): : 3382 - 3394
  • [4] Physical indicators of cartilage health: the relevance of compliance, thickness, swelling and fibrillar texture
    Broom, ND
    Flachsmann, R
    [J]. JOURNAL OF ANATOMY, 2003, 202 (06) : 481 - 494
  • [5] Characterizing damping and restitution in compliant impacts via modified K-V and higher-order linear viscoelastic models
    Butcher, EA
    Segalman, DJ
    [J]. JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 2000, 67 (04): : 831 - 834
  • [6] The use of flat punch indentation to determine the viscoelastic properties in the time and frequency domains of a soft layer bonded to a rigid substrate
    Cao, Yanping
    Ma, Duancheng
    Raabe, Dierk
    [J]. ACTA BIOMATERIALIA, 2009, 5 (01) : 240 - 248
  • [7] Cheng L, 2000, J POLYM SCI POL PHYS, V38, P10, DOI 10.1002/(SICI)1099-0488(20000101)38:1<10::AID-POLB2>3.0.CO
  • [8] 2-6
  • [9] Flat indentation of a viscoelastic polymer film on a rigid substrate
    Choi, Seung Tae
    Lee, Seung Ryoon
    Earmme, Youn Young
    [J]. ACTA MATERIALIA, 2008, 56 (19) : 5377 - 5387
  • [10] de Freitas P., 2010, J BIOMED MATER RES B, V78B, P347