Dopamine molecularly imprinted electrochemical sensor based on graphene-chitosan composite

被引:85
作者
Liu, Bin [1 ]
Lian, Hui Ting [1 ]
Yin, Jing Fen [1 ]
Sun, Xiang Ying [1 ]
机构
[1] Huaqiao Univ, Coll Mat Sci & Engn, Xiamen 361021, Peoples R China
基金
国家高技术研究发展计划(863计划); 中国国家自然科学基金;
关键词
Graphene; Molecularly imprinted technique; Electrochemical sensor; Dopamine; ASCORBIC-ACID; MODIFIED ELECTRODE; URIC-ACID; SHEETS; FILMS; NANOCOMPOSITE; BIOSENSOR; GRAPHITE; OXIDE; NANOPARTICLE;
D O I
10.1016/j.electacta.2012.04.081
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A molecularly imprinted polymers (MIPs) electrochemical sensor based on graphene (GR)-chitosan (CS) composite was constructed, finally used in dopamine (DA) measurement. The MIPs-GR sensor was prepared through electrodepositing DA-GR-CS composited film on the glass carbon electrode (GCE) and then removing DA from the film via electrochemical induced elution. X-ray diffraction (XRD), attenuated total reflection infrared spectroscopy (ATR-IR), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV) characterizations indicated that MIPs-GR/GCE formed an affinity film. Owing to excellent electronic properties, unique two-dimensional structure and large surface area of GR, the prepared sensor exhibited highly sensitive response to the oxidation of DA with enhanced current signal and short response time. The oxidation peak current of DPV was well-proportional to the concentration of DA in the range from 1.0 x 10(-9) to 8.0 x 10(-8) and 1.0 x 10(-7) to 1.0 x 10(-4) M. The developed sensor obtained a recovery of 96.7-105.0% in the DA determination of blood serum, resulted from the specific recognition to DA against the structural analog and coexisting interferences. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:108 / 114
页数:7
相关论文
共 50 条
[1]   Simultaneous electrochemical detection of multiple analytes based on dual signal amplification of single-walled carbon nanotubes and multi-labeled graphene sheets [J].
Bai, Lijuan ;
Yuan, Ruo ;
Chai, Yaqin ;
Zhuo, Ying ;
Yuan, Yali ;
Wang, Yan .
BIOMATERIALS, 2012, 33 (04) :1090-1096
[2]  
BERNHEIMER H, 1973, J NEUROL SCI, V20, P415, DOI 10.1016/0022-510X(73)90175-5
[3]   Carbon nanotube electrode for oxidation of dopamine [J].
Britto, PJ ;
Santhanam, KSV ;
Ajayan, PM .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1996, 41 (01) :121-125
[4]   A route to high surface area, porosity and inclusion of large molecules in crystals [J].
Chae, HK ;
Siberio-Pérez, DY ;
Kim, J ;
Go, Y ;
Eddaoudi, M ;
Matzger, AJ ;
O'Keeffe, M ;
Yaghi, OM .
NATURE, 2004, 427 (6974) :523-527
[5]  
Chen J.J., INT J ENV ANAL CHEM
[6]   Intrinsic and extrinsic performance limits of graphene devices on SiO2 [J].
Chen, Jian-Hao ;
Jang, Chaun ;
Xiao, Shudong ;
Ishigami, Masa ;
Fuhrer, Michael S. .
NATURE NANOTECHNOLOGY, 2008, 3 (04) :206-209
[7]   Graphene Oxide Based Photoinduced Charge Transfer Label-Free Near-Infrared Fluorescent Biosensor for Dopamine [J].
Chen, Jin-Long ;
Yan, Xiu-Ping ;
Meng, Kang ;
Wang, Shu-Feng .
ANALYTICAL CHEMISTRY, 2011, 83 (22) :8787-8793
[8]   A novel molecularly imprinted polymer thin film as biosensor for uric acid [J].
Chen, Po-Yen ;
Vittal, R. ;
Nien, Po-Chin ;
Liou, Guey-Sheng ;
Ho, Kuo-Chuan .
TALANTA, 2010, 80 (03) :1145-1151
[9]   Preparation and Application of Urea Electrochemical Sensor Based on Chitosan Molecularly Imprinted Films [J].
Chen, Yan-Ping ;
Liu, Bin ;
Lian, Hui-Ting ;
Sun, Xiang-Ying .
ELECTROANALYSIS, 2011, 23 (06) :1454-1461
[10]   A voltammetric sensor based on graphene-modified electrode for simultaneous determination of catechol and hydroquinone [J].
Du, Haijun ;
Ye, Jianshan ;
Zhang, Jiaqi ;
Huang, Xiaodan ;
Yu, Chengzhong .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 650 (02) :209-213