Value of liver iron concentration in healthy volunteers assessed by MRI

被引:26
作者
Obrzut, Marzanna [1 ,2 ]
Atamaniuk, Vitaliy [1 ]
Glaser, Kevin J. [2 ]
Chen, Jun [2 ]
Ehman, Richard L. [2 ]
Obrzut, Bogdan [3 ]
Cholewa, Marian [1 ]
Gutkowski, Krzysztof [4 ]
机构
[1] Univ Rzeszow, Coll Nat Sci, Inst Phys, Dept Biophys, Rzeszow, Poland
[2] Mayo Clin, Dept Radiol, Rochester, MN USA
[3] Univ Rzeszow, Med Coll, Inst Med Sci, Dept Obstet & Gynecol, Rzeszow, Poland
[4] Teaching Hosp 1, Dept Gastroenterol & Hepatol, Internal Dis Unit, Rzeszow, Poland
关键词
SICKLE-CELL-DISEASE; MAGNETIC-RESONANCE; NONINVASIVE MEASUREMENT; SERUM FERRITIN; HFE MUTATIONS; OVERLOAD; QUANTIFICATION; DIAGNOSIS; HEMOCHROMATOSIS; THALASSEMIA;
D O I
10.1038/s41598-020-74968-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Iron overload is a relatively common clinical condition resulting from disorders such as hereditary hemochromatosis, thalassemia, sickle cell disease, and myelodysplasia that can lead to progressive fibrosis and eventually cirrhosis of the liver. Therefore, it is essential to recognize the disease process at the earliest stage. Liver biopsy is the reference test for the assessment of liver fibrosis. It also allows for quantifying liver iron concentration (LIC) in patients. However, this is an invasive method with significant limitations and possible risks. Magnetic resonance imaging (MRI) and evaluation of the R2* relaxation rate can be an alternative to biopsy for assessing LIC. However, it causes a need for accurate R2* data corresponding to standard value for further comparison with examined patients. This study aimed to assess the normative values of liver R2* in healthy individuals. A total of 100 volunteers that met established criteria were enrolled in the study: 36 (36%) men and 64 (64%) women. The mean age was 22.9 years (range 20 to 32 years). R2* was estimated by an MRI exam with a 1.5 T clinical magnetic resonance scanner. Images for measuring the LIC and liver fat concentration were obtained using the IDEAL-IQ technique for liver imaging. The Mean (SD) liver R2* was 28.34 (2.25) s(-1) (95% CI, 27.78-28.90, range 23.67-33.00 s(-1)) in females, 29.57 (3.20) s(-1) (95% CI, 28.49-30.66, range 23.93-37.77 s(-1)) in males, and 28.72 (2.69) s(-1) (range 23.67-37.77 s(-1)) in the whole group. R2* value in this particular population with a high proportion of young women did not exceed 38 s(-1). In the absence of fibrosis or steatosis, liver stiffness and fat fraction did not show any relationship with R2*.
引用
收藏
页数:8
相关论文
共 46 条
[11]   Noninvasive measurement of iron: report of an NIDDK workshop [J].
Brittenham, GM ;
Badman, DG .
BLOOD, 2003, 101 (01) :15-19
[12]   HEPATIC IRON STORES AND PLASMA FERRITIN CONCENTRATION IN PATIENTS WITH SICKLE-CELL-ANEMIA AND THALASSEMIA MAJOR [J].
BRITTENHAM, GM ;
COHEN, AR ;
MCLAREN, CE ;
MARTIN, MB ;
GRIFFITH, PM ;
NIENHUIS, AW ;
YOUNG, NS ;
ALLEN, CJ ;
FARRELL, DE ;
HARRIS, JW .
AMERICAN JOURNAL OF HEMATOLOGY, 1993, 42 (01) :81-85
[13]   HEPATIC IRON OVERLOAD - DIAGNOSIS AND QUANTIFICATION BY NONINVASIVE IMAGING [J].
CHEZMAR, JL ;
NELSON, RC ;
MALKO, JA ;
BERNARDINO, ME .
GASTROINTESTINAL RADIOLOGY, 1990, 15 (01) :27-31
[14]   Non-invasive measurement of liver iron concentration using 3-Tesla magnetic resonance imaging: validation against biopsy [J].
d'Assignies, Gaspard ;
Paisant, Anita ;
Bardou-Jacquet, Edouard ;
Boulic, Anne ;
Bannier, Elise ;
Laine, Fabrice ;
Ropert, Martine ;
Morcet, Jeff ;
Saint-Jalmes, Herve ;
Gandon, Yves .
EUROPEAN RADIOLOGY, 2018, 28 (05) :2022-2030
[15]   Hepatic iron overload: Diagnosis and quantification with MR imaging [J].
Ernst, O ;
Sergent, G ;
Bonvarlet, P ;
CanvaDelcambre, V ;
Paris, JC ;
LHermine, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (05) :1205-1208
[16]   Non-invasive assessment of hepatic iron stores by MRI [J].
Gandon, Y ;
Olivié, D ;
Guyader, D ;
Aubé, C ;
Oberti, F ;
Sebille, V ;
Deugnier, Y .
LANCET, 2004, 363 (9406) :357-362
[17]   HEMOCHROMATOSIS - DIAGNOSIS AND QUANTIFICATION OF LIVER IRON WITH GRADIENT-ECHO MR-IMAGING [J].
GANDON, Y ;
GUYADER, D ;
HEAUTOT, JF ;
REDA, MI ;
YAOUANQ, J ;
BUHE, T ;
BRISSOT, P ;
CARSIN, M ;
DEUGNIER, Y .
RADIOLOGY, 1994, 193 (02) :533-538
[18]   Biopsy-based calibration of T2*magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan [J].
Garbowski, Maciej W. ;
Carpenter, John-Paul ;
Smith, Gillian ;
Roughton, Michael ;
Alam, Mohammed H. ;
He, Taigang ;
Pennell, Dudley J. ;
Porter, John B. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
[19]  
Garcia-Compean Diego, 2004, Ann Hepatol, V3, P100
[20]  
Ghavamzadeh Ardeshir, 2015, Int J Hematol Oncol Stem Cell Res, V9, P55