Transcatheter Closure of Adult Patent Ductus Arteriosus with Severe Pulmonary Hypertension

被引:10
作者
Ji, Qiang [1 ]
Feng, Jing [2 ]
Mei, Yunqing [1 ]
Wang, Xisheng [1 ]
Cai, Jiangzhi [1 ]
Sun, Yifeng [1 ]
Zhou, Yongxin [1 ]
Li, Dawen [1 ]
Wang, Yongwu [1 ]
机构
[1] Tongji Univ, Tongji Hosp, Dept Cardiovasc Thorac Surg, Shanghai 200065, Peoples R China
[2] Tongji Univ, Inst Heart Lung Blood Vessel Dis, Heart Lung Blood Vessel Ctr, Shanghai 200065, Peoples R China
关键词
patent ductus arteriosus; pulmonary hypertension; trial balloon occlusion; Amplatzer occluder device;
D O I
10.1291/hypres.31.1997
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The purpose of this study was to investigate the application of trial balloon occlusion for permanent closure of patent ductus arteriosus (PDA) with severe pulmonary hypertension (PH) in adults, and to assess its immediate and short-term results. From September 1999 to September 2005, a total of ten adults (two males, ages ranging from 20 to 54 years) with PDA who met the criterion for severe PH (basal pulmonary vascular resistance >8 Wood units) received trial balloon occlusion via an embolectomy balloon catheter. Post-occlusion hemodynamics, along with an overall clinical and hemodynamic assessment, was used to consider the indication of closure of PDA. Nine of the patients underwent successful transcatheter closure of PDA and subsequently used Amplatzer occluder devices. Chest X-ray, cardiography and echocardiography were used for follow-up evaluation of the treatment within 6 months after successful closure of PDA. No patient had a detectable residual shunt by color flow mapping or any other complications (device migration, hemolysis, endocarditis, etc.) at follow-up. In conclusion, trial balloon occlusion helps to determine anticipated hemodynamics after closure of PDA, so it is conducive to indicating permanent closure of adult PDA with reversible but severe PH. Furthermore, satisfactory immediate and short-term outcomes have proven this method to be safe and valid. (Hypertens Res 2008; 31: 1997-2002)
引用
收藏
页码:1997 / 2002
页数:6
相关论文
共 50 条
  • [41] Transcatheter closure of Patent Ductus Arteriosus through only venous route
    Sheikh, Abdul Malik
    Duke, Abdul Karim
    Sattar, Hina
    [J]. JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2018, 68 (03) : 469 - 470
  • [42] Transcatheter closure of patent ductus arteriosus using controlled release coils
    Celiker, A
    Bilgic, A
    Alehan, D
    Ceviz, N
    Lenk, M
    [J]. ACTA PAEDIATRICA JAPONICA, 1996, 38 (05): : 500 - 505
  • [43] Transcatheter Closure of Patent Ductus Arteriosus in Children with the Occlutech Duct Occluder
    Bilici, Meki
    Demir, Fikri
    Akin, Alper
    Ture, Mehmet
    Balik, Hasan
    Kuyumcu, Mahir
    [J]. PEDIATRIC CARDIOLOGY, 2017, 38 (08) : 1598 - 1605
  • [44] Transcatheter closure of patent ductus arteriosus with Nit-Occlud coils
    Celiker, A
    Aypar, E
    Karagöz, T
    Dilber, E
    Ceviz, N
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 65 (04) : 569 - 576
  • [45] Radiation exposure in transcatheter patent ductus arteriosus closure: time to tune?
    Villemain, Olivier
    Malekzadeh-Milani, Sophie
    Sitefane, Fidelio
    Mostefa-Kara, Meriem
    Boudjemline, Younes
    [J]. CARDIOLOGY IN THE YOUNG, 2018, 28 (05) : 653 - 660
  • [46] Transcatheter closure of patent ductus arteriosus in an infant weighing 1180 g
    Haneda, N
    Masue, M
    Tasaka, M
    Fukui, C
    Saito, K
    Yamaguchi, S
    [J]. PEDIATRICS INTERNATIONAL, 2001, 43 (02) : 176 - 178
  • [47] Transcatheter closure of patent ductus arteriosus in a tiniest baby - 510 grams
    Taylor, Rachel
    Forbes, Michael J.
    Kobayashi, Daisuke
    [J]. PROGRESS IN PEDIATRIC CARDIOLOGY, 2020, 57
  • [48] Comparison of transcatheter patent ductus arteriosus closure between children and adults
    Jun Yasuhara
    Toshiki Kuno
    Takashi Kumamoto
    Takuro Kojima
    Hiroyuki Shimizu
    Shigeki Yoshiba
    Toshiki Kobayashi
    Naokata Sumitomo
    [J]. Heart and Vessels, 2020, 35 : 1605 - 1613
  • [49] Transcatheter closure for patent ductus arteriosus in patients with Eisenmenger syndrome: to do or not?
    Jing Xu
    Liang Wang
    Yunli Shen
    Liang Geng
    Fadong Chen
    [J]. BMC Cardiovascular Disorders, 20
  • [50] Prediction value of pulmonary hypertension in newly identified left ventricular dysfunction among adult patients after patent ductus arteriosus closure
    Chen, Peng-yuan
    Luo, Dong-ling
    Li, He-zhi
    Fei, Hong-wen
    Huang, Tao
    Huang, Yi-gao
    Chen, Ji-mei
    Zhuang, Jian
    He, Peng-cheng
    Zhang, Cao-jin
    [J]. PULMONARY CIRCULATION, 2019, 9 (04)