Single isocenter stereotactic radiosurgery for patients with multiple brain metastases: dosimetric comparison of VMAT and a dedicated DCAT planning tool

被引:46
作者
Hofmaier, Jan [1 ]
Bodensohn, Raphael [1 ]
Garny, Sylvia [1 ]
Hadi, Indrawati [1 ]
Fleischmann, Daniel F. [1 ,2 ,3 ]
Eder, Michael [1 ]
Dinc, Yavuz [1 ]
Reiner, Michael [1 ]
Corradini, Stefanie [1 ]
Parodi, Katia [4 ]
Belka, Claus [1 ,2 ]
Niyazi, Maximilian [1 ,2 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiat Oncol, Marchioninistr 15, D-81377 Munich, Germany
[2] German Canc Consortium DKTK, Munich, Germany
[3] German Canc Res Ctr, Heidelberg, Germany
[4] Ludwig Maximilians Univ Munchen, Fac Phys, Dept Med Phys, Munich, Germany
关键词
Stereotactic radiosurgery; Brain metastases; Dynamic conformal arc therapy; Single Isocenter; VMAT; DYNAMIC CONFORMAL ARCS; RADIONECROSIS; JLGK0901; THERAPY; RISK; TIME;
D O I
10.1186/s13014-019-1315-z
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BackgroundIn this dosimetric study, a dedicated planning tool for single isocenter stereotactic radiosurgery for multiple brain metastases using dynamic conformal arc therapy (DCAT) was compared to standard volumetric modulated arc therapy (VMAT).MethodsTwenty patients with a total of 66 lesions who were treated with the DCAT tool were included in this study. Single fraction doses of 15-20Gy were prescribed to each lesion. Patients were re-planned using non-coplanar VMAT. Number of monitor units as well as V-4Gy, V-5Gy and V-8Gy were extracted for every plan. Using a density-based clustering algorithm, V-10Gy and V-12Gy and the volume receiving half of the prescribed dose were extracted for every lesion. Gradient indices and conformity indices were calculated. The correlation of the target sphericity, a measure of how closely the shape of the target PTV resembles a sphere, to the difference in V-10Gy and V-12Gy between the two techniques was assessed using Spearman's correlation coefficient.ResultsThe automated DCAT planning tool performed significantly better in terms of all investigated metrics (p<0.05), in particular healthy brain sparing (V-10Gy: median 3.2cm(3) vs. 4.9cm(3)), gradient indices (median 5.99 vs. 7.17) and number of monitor units (median 4569 vs. 5840 MU). Differences in conformity indices were minimal (median 0.75 vs. 0.73) but still significant (p<0.05). A moderate correlation between PTV sphericity and the difference of V-10Gy and V-12Gy between the two techniques was found (Spearman's rho=0.27 and 0.30 for V-10Gy and V-12Gy, respectively, p<0.05).ConclusionsThe dedicated DCAT planning tool performed better than VMAT in terms of healthy brain sparing and treatment efficiency, in particular for nearly spherical lesions. In contrast, VMAT can be superior in cases with irregularly shaped lesions.
引用
收藏
页数:8
相关论文
共 25 条
  • [11] CEREBRAL RADIONECROSIS - INCIDENCE AND RISK IN RELATION TO DOSE, TIME, FRACTIONATION AND VOLUME
    MARKS, JE
    BAGLAN, RJ
    PRASSAD, SC
    BLANK, WF
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (02): : 243 - 252
  • [12] Stereotactic radiosurgery for brain metastases: analysis of outcome and risk of brain radionecrosis
    Minniti, Giuseppe
    Clarke, Enrico
    Lanzetta, Gaetano
    Osti, Mattia Falchetto
    Trasimeni, Guido
    Bozzao, Alessandro
    Romano, Andrea
    Enrici, Riccardo Maurizi
    [J]. RADIATION ONCOLOGY, 2011, 6
  • [13] Comparison of volumetric-modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgery
    Molinier, Jessica
    Kerr, Christine
    Simeon, Sebastien
    Ailleres, Norbert
    Charissoux, Marie
    Azria, David
    Fenoglietto, Pascal
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 92 - 101
  • [14] A Systematic Analysis of 2 Monoisocentric Techniques for the Treatment of Multiple Brain Metastases
    Narayanasamy, Ganesh
    Stathakis, Sotirios
    Gutierrez, Alonso N.
    Pappas, Evangelos
    Crownover, Richard
    Floyd, John R., II
    Papanikolaou, Niko
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (05) : 639 - 644
  • [15] HyperArc VMAT planning for single and multiple brain metastases stereotactic radiosurgery: a new treatment planning approach
    Ohira, Shingo
    Ueda, Yoshihiro
    Akino, Yuichi
    Hashimoto, Misaki
    Masaoka, Akira
    Hirata, Takero
    Miyazaki, Masayoshi
    Koizumi, Masahiko
    Teshima, Teruki
    [J]. RADIATION ONCOLOGY, 2018, 13
  • [16] A simple scoring ratio to index the conformity of radiosurgical treatment plans - Technical note
    Paddick, I
    [J]. JOURNAL OF NEUROSURGERY, 2000, 93 : 219 - 222
  • [17] A simple dose gradient measurement tool to complement the conformity index
    Paddick, Ian
    Lippitz, Bodo
    [J]. JOURNAL OF NEUROSURGERY, 2006, 105 : 194 - 201
  • [18] Cerebral radiation necrosis: Incidence, outcomes, and risk factors with emphasis on radiation parameters and chemotherapy
    Ruben, Jeremy D.
    Dally, Michael
    Bailey, Michael
    Smith, Robin
    McLean, Catriona A.
    Fedele, Pasqual
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02): : 499 - 508
  • [19] Linac-based radiosurgery for multiple brain metastases: Comparison between two mono-isocenter techniques with multiple non-coplanar arcs
    Ruggieri, Ruggero
    Naccarato, Stefania
    Mazzola, Rosario
    Ricchetti, Francesco
    Corradini, Stefanie
    Fiorentino, Alba
    Alongi, Filippo
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 132 : 70 - 78
  • [20] Linac-based VMAT radiosurgery for multiple brain lesions: comparison between a conventional multi-isocenter approach and a new dedicated mono-isocenter technique
    Ruggieri, Ruggero
    Naccarato, Stefania
    Mazzola, Rosario
    Ricchetti, Francesco
    Corradini, Stefanie
    Fiorentino, Alba
    Alongi, Filippo
    [J]. RADIATION ONCOLOGY, 2018, 13